  • Needle segmentation in ultrasound images is challenging due to artifacts, noise, and occlusion, especially with limited data availability.
  • The paper presents a novel approach that combines Kalman Filter techniques with data-driven learning, using both needle features and motion.
  • The method offers three key contributions: a compatible framework for encoder-decoder architectures, superior performance compared to state-of-the-art models, and the first implementation of a learnable filter to incorporate non-linear needle motion.

Plain English Explanation

Ultrasound imaging is a valuable tool in medical procedures, but it can be tricky to accurately track the position of a thin needle as it moves through the body. This is because the ultrasound images often contain distortions, background noise, and can even lose sight of the needle entirely at times. The researchers in this paper wanted to find a way to better track the needle's movements, even in challenging situations where there isn't a lot of training data available.

Their approach combines traditional mathematical techniques, like the Kalman Filter, with modern machine learning methods. This allows the system to learn from examples of needle movements, while also using mathematical models to predict how the needle will move. The result is a more robust and accurate way to track the needle's position, even when the ultrasound image quality is poor or the needle is partially obscured.

The key innovations in this paper are:

  1. A framework that can be easily integrated into common neural network architectures used for image segmentation.
  2. Significantly better performance than other state-of-the-art needle tracking models, reducing errors in both the needle tip position and the overall needle length.
  3. The first use of a "learnable filter" to incorporate the complex, non-linear motions of the needle, further improving the tracking accuracy.

Technical Explanation

The paper presents a novel approach for needle segmentation in 2D ultrasound imaging that combines classical Kalman Filter (KF) techniques with data-driven learning. The proposed method utilizes both needle features and needle motion to achieve superior performance compared to recent state-of-the-art models.

The key technical contributions are:

  1. Compatible Framework: The authors develop a framework that can be seamlessly integrated into commonly used encoder-decoder style neural network architectures for image segmentation tasks.

  2. Improved Performance: The novel Convolutional Neural Network (CNN) based KF-inspired block demonstrates a 15% reduction in pixel-wise needle tip error and an 8% reduction in length error compared to recent state-of-the-art needle segmentation models.

  3. Learnable Filter for Non-linear Motion: To the authors' knowledge, they are the first to implement a learnable filter that can incorporate the complex, non-linear motion of the needle, further improving the segmentation accuracy.

The paper evaluates the proposed method on publicly available datasets and shows significant improvements over existing approaches, particularly in challenging scenarios with limited training data.

Critical Analysis

The paper presents a well-designed and innovative approach to the problem of needle segmentation in ultrasound images. The authors' use of a hybrid model that combines classical Kalman Filter techniques with data-driven learning is a clever way to leverage the strengths of both methodologies.

However, the paper does not address some potential limitations of the proposed approach. For example, the method may be sensitive to changes in the ultrasound imaging equipment or settings, as it relies on learning specific needle features and motion patterns. Additionally, the paper does not discuss the computational complexity of the KF-inspired block, which could be an important consideration for real-time clinical applications.

Furthermore, the paper could have explored the generalization of the method to other medical imaging modalities beyond 2D ultrasound, such as 3D ultrasound or other imaging techniques like X-ray or CT scans. Expanding the scope of the research could further demonstrate the versatility and broader applicability of the proposed approach.

Overall, the paper presents a significant advance in the field of needle segmentation and tracking, and the authors' technical contributions are valuable. However, addressing the potential limitations and exploring additional applications could further strengthen the impact and practical relevance of this research.

Conclusion

This paper introduces a novel approach for needle segmentation in 2D ultrasound imaging that combines classical Kalman Filter techniques with data-driven learning. The proposed method offers several key advantages, including a compatible framework for integration into common neural network architectures, superior performance compared to state-of-the-art models, and the first implementation of a learnable filter to incorporate the complex, non-linear motion of the needle.

The researchers' innovative hybrid approach, blending traditional mathematical models with modern machine learning, demonstrates the potential for combining different techniques to tackle challenging problems in medical imaging. While the paper has some limitations, the significant improvements in needle segmentation accuracy and the potential for broader applications make this a valuable contribution to the field.



This summary was produced with help from an AI and may contain inaccuracies - check out the links to read the original source documents!

Follow @aimodelsfyi on 𝕏 →

Related Papers

🧠

Total Score

0

Motion Informed Needle Segmentation in Ultrasound Images

Raghavv Goel, Cecilia Morales, Manpreet Singh, Artur Dubrawski, John Galeotti, Howie Choset

Segmenting a moving needle in ultrasound images is challenging due to the presence of artifacts, noise, and needle occlusion. This task becomes even more demanding in scenarios where data availability is limited. In this paper, we present a novel approach for needle segmentation for 2D ultrasound that combines classical Kalman Filter (KF) techniques with data-driven learning, incorporating both needle features and needle motion. Our method offers three key contributions. First, we propose a compatible framework that seamlessly integrates into commonly used encoder-decoder style architectures. Second, we demonstrate superior performance compared to recent state-of-the-art needle segmentation models using our novel convolutional neural network (CNN) based KF-inspired block, achieving a 15% reduction in pixel-wise needle tip error and an 8% reduction in length error. Third, to our knowledge we are the first to implement a learnable filter to incorporate non-linear needle motion for improving needle segmentation.

Read more

5/7/2024

Force Sensing Guided Artery-Vein Segmentation via Sequential Ultrasound Images
Total Score

0

Force Sensing Guided Artery-Vein Segmentation via Sequential Ultrasound Images

Yimeng Geng, Gaofeng Meng, Mingcong Chen, Guanglin Cao, Mingyang Zhao, Jianbo Zhao, Hongbin Liu

Accurate identification of arteries and veins in ultrasound images is crucial for vascular examinations and interventions in robotics-assisted surgeries. However, current methods for ultrasound vessel segmentation face challenges in distinguishing between arteries and veins due to their morphological similarities. To address this challenge, this study introduces a novel force sensing guided segmentation approach to enhance artery-vein segmentation accuracy by leveraging their distinct deformability. Our proposed method utilizes force magnitude to identify key frames with the most significant vascular deformation in a sequence of ultrasound images. These key frames are then integrated with the current frame through attention mechanisms, with weights assigned in accordance with force magnitude. Our proposed force sensing guided framework can be seamlessly integrated into various segmentation networks and achieves significant performance improvements in multiple U-shaped networks such as U-Net, Swin-unet and Transunet. Furthermore, we contribute the first multimodal ultrasound artery-vein segmentation dataset, Mus-V, which encompasses both force and image data simultaneously. The dataset comprises 3114 ultrasound images of carotid and femoral vessels extracted from 105 videos, with corresponding force data recorded by the force sensor mounted on the US probe. Our code and dataset will be publicly available.

Read more

8/1/2024

Needle Segmentation Using GAN: Restoring Thin Instrument Visibility in Robotic Ultrasound
Total Score

0

Needle Segmentation Using GAN: Restoring Thin Instrument Visibility in Robotic Ultrasound

Zhongliang Jiang, Xuesong Li, Xiangyu Chu, Angelos Karlas, Yuan Bi, Yingsheng Cheng, K. W. Samuel Au, Nassir Navab

Ultrasound-guided percutaneous needle insertion is a standard procedure employed in both biopsy and ablation in clinical practices. However, due to the complex interaction between tissue and instrument, the needle may deviate from the in-plane view, resulting in a lack of close monitoring of the percutaneous needle. To address this challenge, we introduce a robot-assisted ultrasound (US) imaging system designed to seamlessly monitor the insertion process and autonomously restore the visibility of the inserted instrument when misalignment happens. To this end, the adversarial structure is presented to encourage the generation of segmentation masks that align consistently with the ground truth in high-order space. This study also systematically investigates the effects on segmentation performance by exploring various training loss functions and their combinations. When misalignment between the probe and the percutaneous needle is detected, the robot is triggered to perform transverse searching to optimize the positional and rotational adjustment to restore needle visibility. The experimental results on ex-vivo porcine samples demonstrate that the proposed method can precisely segment the percutaneous needle (with a tip error of $0.37pm0.29mm$ and an angle error of $1.19pm 0.29^{circ}$). Furthermore, the needle appearance can be successfully restored under the repositioned probe pose in all 45 trials, with repositioning errors of $1.51pm0.95mm$ and $1.25pm0.79^{circ}$. from latex to text with math symbols

Read more

7/29/2024

🗣️

Total Score

0

A kinetic approach to consensus-based segmentation of biomedical images

Raffaella Fiamma Cabini, Anna Pichiecchio, Alessandro Lascialfari, Silvia Figini, Mattia Zanella

In this work, we apply a kinetic version of a bounded confidence consensus model to biomedical segmentation problems. In the presented approach, time-dependent information on the microscopic state of each particle/pixel includes its space position and a feature representing a static characteristic of the system, i.e. the gray level of each pixel. From the introduced microscopic model we derive a kinetic formulation of the model. The large time behavior of the system is then computed with the aid of a surrogate Fokker-Planck approach that can be obtained in the quasi-invariant scaling. We exploit the computational efficiency of direct simulation Monte Carlo methods for the obtained Boltzmann-type description of the problem for parameter identification tasks. Based on a suitable loss function measuring the distance between the ground truth segmentation mask and the evaluated mask, we minimize the introduced segmentation metric for a relevant set of 2D gray-scale images. Applications to biomedical segmentation concentrate on different imaging research contexts.

Read more

6/17/2024