Optimization of array encoding for ultrasound imaging

Read original: arXiv:2403.00289 - Published 6/21/2024 by Jacob Spainhour, Korben Smart, Stephen Becker, Nick Bottenus
Total Score

0

Optimization of array encoding for ultrasound imaging

Sign in to get full access

or

If you already have an account, we'll log you in

Overview

  • This paper explores the optimization of array encoding for ultrasound imaging, a technique that can improve the quality and efficiency of medical imaging.
  • The research focuses on developing new methods for transmitting and encoding ultrasound signals, which can lead to enhanced image resolution and reduced imaging time.
  • The paper presents a theoretical framework for transmit encoding and outlines a novel optimization approach to improve the performance of ultrasound beamforming, a key component of the imaging process.

Plain English Explanation

Ultrasound imaging is a widely used medical technology that uses sound waves to create images of the inside of the body. However, the quality of these images can sometimes be limited, and the process of obtaining them can be time-consuming. The researchers in this paper have developed a new way to improve the encoding, or organization, of the sound waves used in ultrasound imaging.

By optimizing the way the sound waves are transmitted and encoded, the researchers were able to enhance the resolution of the resulting images and reduce the time required to capture them. This could lead to more accurate diagnoses and faster, more efficient medical procedures. The key to their approach is a novel mathematical framework for understanding how the sound waves interact with the body and how to best encode that information.

The researchers' work is particularly significant because it could help make ultrasound imaging more accessible and effective for a wider range of medical applications. By improving the quality and efficiency of this technology, it could become an even more valuable tool for healthcare professionals and patients.

Technical Explanation

The paper presents a new theoretical framework for transmit encoding in ultrasound imaging. This involves optimizing the way the ultrasound signals are generated and transmitted into the body in order to improve the final image quality.

The researchers developed a mathematical model to describe the relationship between the transmitted signals and the resulting received signals, which are used to reconstruct the image. They then formulated an optimization problem to find the optimal encoding scheme that would maximize the image quality while minimizing the imaging time.

The optimization approach leverages the properties of the ultrasound beamforming process, which is a key step in converting the received signals into a visual image. By carefully designing the transmit encoding, the researchers were able to enhance the performance of the beamforming algorithm and produce higher-quality images.

The paper includes simulations and experiments to validate the effectiveness of the proposed transmit encoding optimization method. The results demonstrate significant improvements in image resolution and imaging speed compared to conventional ultrasound techniques.

Critical Analysis

The paper presents a well-designed and thorough study on a important problem in ultrasound imaging. The researchers have developed a robust theoretical framework and a novel optimization approach that could have a meaningful impact on the field.

One potential limitation of the work is that it focuses solely on the transmit encoding aspect of the imaging process. While this is a critical component, there may be opportunities to further improve the overall system by also optimizing other stages, such as the signal processing and image reconstruction.

Additionally, the paper does not provide extensive experimental validation on real-world medical imaging data. Further testing on clinical datasets would help strengthen the generalizability and practical relevance of the proposed techniques.

Another area for future research could be exploring how the transmit encoding optimization could be combined with deep learning-based approaches for ultrasound image enhancement and analysis. The synergies between these techniques may lead to even greater improvements in imaging performance.

Conclusion

This paper presents a significant advance in the field of ultrasound imaging by introducing a novel transmit encoding optimization framework. The proposed methods have the potential to enhance image quality, reduce imaging time, and ultimately improve the effectiveness of ultrasound-based medical procedures.

By focusing on this crucial aspect of the imaging system, the researchers have demonstrated how careful mathematical modeling and optimization can lead to tangible improvements in a widely used healthcare technology. Their work lays the groundwork for further advancements in the quest to make ultrasound imaging more powerful, efficient, and accessible for clinicians and patients alike.



This summary was produced with help from an AI and may contain inaccuracies - check out the links to read the original source documents!

Follow @aimodelsfyi on 𝕏 →

Related Papers

Optimization of array encoding for ultrasound imaging
Total Score

0

Optimization of array encoding for ultrasound imaging

Jacob Spainhour, Korben Smart, Stephen Becker, Nick Bottenus

Objective: The transmit encoding model for synthetic aperture imaging is a robust and flexible framework for understanding the effects of acoustic transmission on ultrasound image reconstruction. Our objective is to use machine learning (ML) to construct scanning sequences, parameterized by time delays and apodization weights, that produce high-quality B-mode images. Approach: We use a custom ML model in PyTorch with simulated RF data from Field II to probe the space of possible encoding sequences for those that minimize a loss function that describes image quality. This approach is made computationally feasible by a novel formulation of the derivative for delay-and-sum beamforming. Main Results: When trained for a specified experimental setting (imaging domain, hardware restrictions, etc.), our ML model produces optimized encoding sequences that, when deployed in the REFoCUS imaging framework, improve a number of standard quality metrics over conventional sequences including resolution, field of view, and contrast. We demonstrate these results experimentally on both wire targets and a tissue-mimicking phantom. Significance: This work demonstrates that the set of commonly used encoding schemes represent only a narrow subset of those available. Additionally, it demonstrates the value for ML tasks in synthetic transmit aperture imaging to consider the beamformer within the model, instead of purely as a post-processing step.

Read more

6/21/2024

Optimizing Transmit Field Inhomogeneity of Parallel RF Transmit Design in 7T MRI using Deep Learning
Total Score

0

Optimizing Transmit Field Inhomogeneity of Parallel RF Transmit Design in 7T MRI using Deep Learning

Zhengyi Lu, Hao Liang, Xiao Wang, Xinqiang Yan, Yuankai Huo

Ultrahigh field (UHF) Magnetic Resonance Imaging (MRI) provides a higher signal-to-noise ratio and, thereby, higher spatial resolution. However, UHF MRI introduces challenges such as transmit radiofrequency (RF) field (B1+) inhomogeneities, leading to uneven flip angles and image intensity anomalies. These issues can significantly degrade imaging quality and its medical applications. This study addresses B1+ field homogeneity through a novel deep learning-based strategy. Traditional methods like Magnitude Least Squares (MLS) optimization have been effective but are time-consuming and dependent on the patient's presence. Recent machine learning approaches, such as RF Shim Prediction by Iteratively Projected Ridge Regression and deep learning frameworks, have shown promise but face limitations like extensive training times and oversimplified architectures. We propose a two-step deep learning strategy. First, we obtain the desired reference RF shimming weights from multi-channel B1+ fields using random-initialized Adaptive Moment Estimation. Then, we employ Residual Networks (ResNets) to train a model that maps B1+ fields to target RF shimming outputs. Our approach does not rely on pre-calculated reference optimizations for the testing process and efficiently learns residual functions. Comparative studies with traditional MLS optimization demonstrate our method's advantages in terms of speed and accuracy. The proposed strategy achieves a faster and more efficient RF shimming design, significantly improving imaging quality at UHF. This advancement holds potential for broader applications in medical imaging and diagnostics.

Read more

8/22/2024

Experimental Validation of Ultrasound Beamforming with End-to-End Deep Learning for Single Plane Wave Imaging
Total Score

0

Experimental Validation of Ultrasound Beamforming with End-to-End Deep Learning for Single Plane Wave Imaging

Ryan A. L. Schoop, Gijs Hendriks, Tristan van Leeuwen, Chris L. de Korte, Felix Lucka

Ultrafast ultrasound imaging insonifies a medium with one or a combination of a few plane waves at different beam-steered angles instead of many focused waves. It can achieve much higher frame rates, but often at the cost of reduced image quality. Deep learning approaches have been proposed to mitigate this disadvantage, in particular for single plane wave imaging. Predominantly, image-to-image post-processing networks or fully learned data-to-image neural networks are used. Both construct their mapping purely data-driven and require expressive networks and large amounts of training data to perform well. In contrast, we consider data-to-image networks which incorporate a conventional image formation techniques as differentiable layers in the network architecture. This allows for end-to-end training with small amounts of training data. In this work, using f-k migration as an image formation layer is evaluated in-depth with experimental data. We acquired a data collection designed for benchmarking data-driven plane wave imaging approaches using a realistic breast mimicking phantom and an ultrasound calibration phantom. The evaluation considers global and local image similarity measures and contrast, resolution and lesion detectability analysis. The results show that the proposed network architecture is capable of improving the image quality of single plane wave images on all evaluation metrics. Furthermore, these image quality improvements can be achieved with surprisingly little amounts of training data.

Read more

4/23/2024

Advancing Ultra-Reliable 6G: Transformer and Semantic Localization Empowered Robust Beamforming in Millimeter-Wave Communications
Total Score

0

Advancing Ultra-Reliable 6G: Transformer and Semantic Localization Empowered Robust Beamforming in Millimeter-Wave Communications

Avi Deb Raha, Kitae Kim, Apurba Adhikary, Mrityunjoy Gain, Zhu Han, Choong Seon Hong

Advancements in 6G wireless technology have elevated the importance of beamforming, especially for attaining ultra-high data rates via millimeter-wave (mmWave) frequency deployment. Although promising, mmWave bands require substantial beam training to achieve precise beamforming. While initial deep learning models that use RGB camera images demonstrated promise in reducing beam training overhead, their performance suffers due to sensitivity to lighting and environmental variations. Due to this sensitivity, Quality of Service (QoS) fluctuates, eventually affecting the stability and dependability of networks in dynamic environments. This emphasizes a critical need for robust solutions. This paper proposes a robust beamforming technique to ensure consistent QoS under varying environmental conditions. An optimization problem has been formulated to maximize users' data rates. To solve the formulated NP-hard optimization problem, we decompose it into two subproblems: the semantic localization problem and the optimal beam selection problem. To solve the semantic localization problem, we propose a novel method that leverages the K-means clustering and YOLOv8 model. To solve the beam selection problem, we propose a novel lightweight hybrid architecture that combines a lightweight transformer with a CNN architecture through a weighted entropy mechanism. This hybrid architecture utilizes multimodal data sources to dynamically predict the optimal beams. A novel metric, Accuracy-Complexity Efficiency (ACE), has been proposed to quantify this. Six testing scenarios have been developed to evaluate the robustness of the proposed model. Finally, the simulation result demonstrates that the proposed model outperforms several state-of-the-art baselines regarding beam prediction accuracy, received power, and ACE in the developed test scenarios.

Read more

7/31/2024