Optimizing Transmit Field Inhomogeneity of Parallel RF Transmit Design in 7T MRI using Deep Learning

Read original: arXiv:2408.11323 - Published 8/22/2024 by Zhengyi Lu, Hao Liang, Xiao Wang, Xinqiang Yan, Yuankai Huo
Total Score

0

Optimizing Transmit Field Inhomogeneity of Parallel RF Transmit Design in 7T MRI using Deep Learning

Sign in to get full access

or

If you already have an account, we'll log you in

Overview

  • This paper presents a deep learning approach to optimizing transmit field inhomogeneity in parallel RF transmit design for 7T MRI (magnetic resonance imaging).
  • Parallel RF transmit design is used to improve image quality in high-field MRI, but suffers from transmit field inhomogeneities.
  • The authors propose using deep learning techniques to optimize the transmit field, aiming to improve image uniformity.

Plain English Explanation

The paper focuses on a challenge in high-field MRI (specifically 7 Tesla MRI) called transmit field inhomogeneity. In MRI, radio frequency (RF) signals are used to excite the atoms in the body and generate the image. When using multiple RF transmit coils in parallel (a common technique to improve image quality), the signals can interfere with each other, leading to uneven excitation and poor image uniformity.

The researchers in this paper used a deep learning approach to try to optimize the transmit field and reduce these inhomogeneities. Deep learning is a type of artificial intelligence that can learn patterns from data. In this case, the deep learning model was trained on simulated data to learn how to adjust the signals from the multiple transmit coils to produce a more uniform transmit field.

The goal was to improve the overall quality and consistency of the MRI images by addressing this transmit field issue, which is an important challenge in high-field MRI systems.

Technical Explanation

The paper proposes a deep learning-based method to optimize the transmit field inhomogeneity in parallel RF transmit design for 7T MRI. The authors developed a convolutional neural network (CNN) model that takes in the complex-valued transmit field maps from multiple RF transmit channels and outputs the optimal RF shim values to minimize the transmit field inhomogeneity.

The CNN architecture consists of multiple convolutional, batch normalization, and ReLU activation layers, followed by a fully connected output layer. The model was trained on a large dataset of simulated transmit field maps and corresponding optimal RF shim values.

During inference, the trained CNN model takes the transmit field maps as input and predicts the optimal RF shim values, which are then applied to the parallel transmit system to produce a more homogeneous transmit field. The authors evaluated the performance of their approach using both simulation and experimental data, demonstrating significant improvements in transmit field uniformity compared to conventional methods.

Critical Analysis

The paper provides a promising deep learning-based solution to a well-known challenge in high-field MRI. By optimizing the transmit field inhomogeneity, the proposed method has the potential to improve image quality and consistency, which is crucial for diagnostic and research applications of 7T MRI.

One limitation of the study is that it relies on simulated data for training the deep learning model. While the authors validated the approach using experimental data, it would be valuable to further test the model's performance on a more diverse dataset of real-world transmit field maps.

Additionally, the paper does not explore the potential clinical impact of the improved transmit field uniformity, such as the effect on image-based diagnoses or the ability to conduct more accurate quantitative MRI measurements. Further research in this direction could help demonstrate the practical benefits of the proposed technique.

Conclusion

This paper presents a deep learning-based approach to optimizing transmit field inhomogeneity in parallel RF transmit design for 7T MRI. By training a convolutional neural network to predict optimal RF shim values, the method can significantly improve the uniformity of the transmit field, which is an important challenge in high-field MRI systems.

The proposed technique has the potential to enhance the overall image quality and consistency in 7T MRI, potentially leading to more accurate diagnoses and better quantitative measurements. Further research is needed to validate the model's performance on real-world data and explore the clinical implications of the improved transmit field uniformity.



This summary was produced with help from an AI and may contain inaccuracies - check out the links to read the original source documents!

Follow @aimodelsfyi on 𝕏 →

Related Papers

Optimizing Transmit Field Inhomogeneity of Parallel RF Transmit Design in 7T MRI using Deep Learning
Total Score

0

Optimizing Transmit Field Inhomogeneity of Parallel RF Transmit Design in 7T MRI using Deep Learning

Zhengyi Lu, Hao Liang, Xiao Wang, Xinqiang Yan, Yuankai Huo

Ultrahigh field (UHF) Magnetic Resonance Imaging (MRI) provides a higher signal-to-noise ratio and, thereby, higher spatial resolution. However, UHF MRI introduces challenges such as transmit radiofrequency (RF) field (B1+) inhomogeneities, leading to uneven flip angles and image intensity anomalies. These issues can significantly degrade imaging quality and its medical applications. This study addresses B1+ field homogeneity through a novel deep learning-based strategy. Traditional methods like Magnitude Least Squares (MLS) optimization have been effective but are time-consuming and dependent on the patient's presence. Recent machine learning approaches, such as RF Shim Prediction by Iteratively Projected Ridge Regression and deep learning frameworks, have shown promise but face limitations like extensive training times and oversimplified architectures. We propose a two-step deep learning strategy. First, we obtain the desired reference RF shimming weights from multi-channel B1+ fields using random-initialized Adaptive Moment Estimation. Then, we employ Residual Networks (ResNets) to train a model that maps B1+ fields to target RF shimming outputs. Our approach does not rely on pre-calculated reference optimizations for the testing process and efficiently learns residual functions. Comparative studies with traditional MLS optimization demonstrate our method's advantages in terms of speed and accuracy. The proposed strategy achieves a faster and more efficient RF shimming design, significantly improving imaging quality at UHF. This advancement holds potential for broader applications in medical imaging and diagnostics.

Read more

8/22/2024

🔎

Total Score

0

Volumetric B1+ field homogenization in 7 Tesla brain MRI using metasurface scattering

Gyoungsub Yoon, Sunkyu Yu, Jongho Lee, Namkyoo Park

Ultrahigh field magnetic resonance imaging (UHF MRI) has become an indispensable tool for human brain imaging, offering excellent diagnostic accuracy while avoiding the risks associated with invasive modalities. When the radiofrequency magnetic field of the UHF MRI encounters the multifaceted complexity of the brain, characterized by wavelength-scale, dissipative, and random heterogeneous materials, detrimental mesoscopic challenges such as B1+ field inhomogeneity and local heating arise. Here we develop the metasurface design inspired by scattering theory to achieve the volumetric field homogeneity in the UHF MRI. The method focuses on finding the scattering ansatz systematically and incorporates a pruning technique to achieve the minimum number of participating modes, which guarantees stable practical implementation. Using full-wave analysis of realistic human brain models under a 7 Tesla MRI, we demonstrate more than a twofold improvement in field homogeneity and suppressed local heating, achieving better performance than even the commercial 3 Tesla MRI. The result shows a noninvasive generalization of constant intensity waves in optics, offering a universal methodology applicable to higher Tesla MRI.

Read more

9/10/2024

🖼️

Total Score

0

Image Reconstruction with B0 Inhomogeneity using an Interpretable Deep Unrolled Network on an Open-bore MRI-Linac

Shanshan Shan, Yang Gao, David E. J. Waddington, Hongli Chen, Brendan Whelan, Paul Z. Y. Liu, Yaohui Wang, Chunyi Liu, Hongping Gan, Mingyuan Gao, Feng Liu

MRI-Linac systems require fast image reconstruction with high geometric fidelity to localize and track tumours for radiotherapy treatments. However, B0 field inhomogeneity distortions and slow MR acquisition potentially limit the quality of the image guidance and tumour treatments. In this study, we develop an interpretable unrolled network, referred to as RebinNet, to reconstruct distortion-free images from B0 inhomogeneity-corrupted k-space for fast MRI-guided radiotherapy applications. RebinNet includes convolutional neural network (CNN) blocks to perform image regularizations and nonuniform fast Fourier Transform (NUFFT) modules to incorporate B0 inhomogeneity information. The RebinNet was trained on a publicly available MR dataset from eleven healthy volunteers for both fully sampled and subsampled acquisitions. Grid phantom and human brain images acquired from an open-bore 1T MRI-Linac scanner were used to evaluate the performance of the proposed network. The RebinNet was compared with the conventional regularization algorithm and our recently developed UnUNet method in terms of root mean squared error (RMSE), structural similarity (SSIM), residual distortions, and computation time. Imaging results demonstrated that the RebinNet reconstructed images with lowest RMSE (0.92) at four-time acceleration for simulated brain images. The RebinNet could better preserve structural details and substantially improve the computational efficiency (ten-fold faster) compared to the conventional regularization methods, and had better generalization ability than the UnUNet method. The proposed RebinNet can achieve rapid image reconstruction and overcome the B0 inhomogeneity distortions simultaneously, which would facilitate accurate and fast image guidance in radiotherapy treatments.

Read more

4/16/2024

Optimization of array encoding for ultrasound imaging
Total Score

0

Optimization of array encoding for ultrasound imaging

Jacob Spainhour, Korben Smart, Stephen Becker, Nick Bottenus

Objective: The transmit encoding model for synthetic aperture imaging is a robust and flexible framework for understanding the effects of acoustic transmission on ultrasound image reconstruction. Our objective is to use machine learning (ML) to construct scanning sequences, parameterized by time delays and apodization weights, that produce high-quality B-mode images. Approach: We use a custom ML model in PyTorch with simulated RF data from Field II to probe the space of possible encoding sequences for those that minimize a loss function that describes image quality. This approach is made computationally feasible by a novel formulation of the derivative for delay-and-sum beamforming. Main Results: When trained for a specified experimental setting (imaging domain, hardware restrictions, etc.), our ML model produces optimized encoding sequences that, when deployed in the REFoCUS imaging framework, improve a number of standard quality metrics over conventional sequences including resolution, field of view, and contrast. We demonstrate these results experimentally on both wire targets and a tissue-mimicking phantom. Significance: This work demonstrates that the set of commonly used encoding schemes represent only a narrow subset of those available. Additionally, it demonstrates the value for ML tasks in synthetic transmit aperture imaging to consider the beamformer within the model, instead of purely as a post-processing step.

Read more

6/21/2024