Overview

  • This paper describes a method for generating panoramic tomosynthesis images from cone-beam computed tomography (CBCT) data of the head.
  • The key idea is to simulate the projection geometry of a panoramic X-ray imaging system to reconstruct a panoramic view from the CBCT data.
  • The authors evaluate the performance of this approach on a dataset of patient CBCT scans.

Plain English Explanation

Panoramic X-ray imaging is a common dental procedure that captures a wide, curved view of the teeth and jaws. [object Object] is another imaging technique that provides detailed 3D images of the head and face.

In this work, the researchers developed a way to generate panoramic-style images directly from CBCT data. They did this by simulating the projection geometry of a panoramic X-ray system and then using that to reconstruct a panoramic view from the 3D CBCT scan.

The key advantage of this approach is that it allows dentists to obtain a panoramic view without the need for a separate panoramic X-ray exam. This can save time and radiation exposure for patients.

The researchers tested their method on a dataset of CBCT scans from actual patients and found that the resulting panoramic images were of good quality and resembled those from a traditional panoramic X-ray system.

Technical Explanation

The authors' approach involves simulating the projection geometry of a panoramic X-ray system. Panoramic X-rays are captured by rotating the X-ray source and detector around the patient's head in an arc. To mimic this, the researchers defined a virtual arc trajectory and used it to reproject the 3D CBCT data into a 2D panoramic view.

Specifically, they:

  1. Defined a virtual arc trajectory that approximates the motion of a panoramic X-ray system.
  2. Calculated the projection lines corresponding to each pixel in the desired panoramic image.
  3. Sampled the 3D CBCT volume along these projection lines to generate the 2D panoramic image.

They evaluated this panorama tomosynthesis approach on a dataset of patient CBCT scans, comparing the resulting panoramic images to those from a traditional panoramic X-ray system. The authors found that their simulated panoramic images had good visual quality and were able to depict the major anatomical structures.

Critical Analysis

The primary limitation of this work is that it relies on simulating the panoramic projection geometry, rather than directly acquiring panoramic images. This means the quality of the results is dependent on how accurately the simulation matches the real-world panoramic imaging process.

Additionally, the authors only evaluated their method on a small dataset of patient CBCT scans. Further validation on a larger and more diverse patient population would be needed to fully assess the generalizability of the approach.

Another potential concern is the radiation dose implications. While this method eliminates the need for a separate panoramic X-ray exam, the cumulative dose from the CBCT scan may still be higher than a standalone panoramic X-ray. The authors do not discuss the radiation dose considerations in depth.

Overall, this is an interesting proof-of-concept that demonstrates the potential to leverage CBCT data to generate panoramic-style images. However, further research is needed to fully validate the clinical utility and robustness of the technique.

Conclusion

This paper presents a method for generating panoramic tomosynthesis images directly from cone-beam CT (CBCT) data of the head. By simulating the projection geometry of a panoramic X-ray system, the researchers were able to reconstruct a panoramic view from the 3D CBCT scan.

The key benefit of this approach is that it allows dentists to obtain a panoramic image without the need for a separate panoramic X-ray exam, potentially saving time and reducing radiation exposure for patients. While the authors' initial results are promising, further validation and optimization will be necessary before this technique could be widely adopted in clinical practice.



This summary was produced with help from an AI and may contain inaccuracies - check out the links to read the original source documents!

Follow @aimodelsfyi on 𝕏 →

Related Papers

Panorama Tomosynthesis from Head CBCT with Simulated Projection Geometry
Total Score

0

Panorama Tomosynthesis from Head CBCT with Simulated Projection Geometry

Anusree P. S., Bikram Keshari Parida, Seong Yong Moon, Wonsang You

Cone Beam Computed Tomography (CBCT) and Panoramic X-rays are the most commonly used imaging modalities in dental health care. CBCT can produce three-dimensional views of a patient's head, providing clinicians with better diagnostic capability, whereas Panoramic X-ray can capture the entire maxillofacial region in a single image. If the CBCT is already available, it can be beneficial to synthesize a Panoramic X-ray, thereby avoiding an immediate additional scan and extra radiation exposure. Existing methods focus on delineating an approximate dental arch and creating orthogonal projections along this arch. However, no golden standard is available for such dental arch extractions, and this choice can affect the quality of synthesized X-rays. To avoid such issues, we propose a novel method for synthesizing Panoramic X-rays from diverse head CBCTs, employing a simulated projection geometry and dynamic rotation centers. Our method effectively synthesized panoramic views from CBCT, even for patients with missing or nonexistent teeth and in the presence of severe metal implants. Our results demonstrate that this method can generate high-quality panoramic images irrespective of the CBCT scanner geometry.

Read more

8/21/2024

Edge Projection-Based Adaptive View Selection for Cone-Beam CT
Total Score

0

Edge Projection-Based Adaptive View Selection for Cone-Beam CT

Jingsong Lin, Singanallur Venkatakrishnan, Gregery Buzzard, Amir Koushyar Ziabari, Charles Bouman

Industrial cone-beam X-ray computed tomography (CT) scans of additively manufactured components produce a 3D reconstruction from projection measurements acquired at multiple predetermined rotation angles of the component about a single axis. Typically, a large number of projections are required to achieve a high-quality reconstruction, a process that can span several hours or days depending on the part size, material composition, and desired resolution. This paper introduces a novel real-time system designed to optimize the scanning process by intelligently selecting the best next angle based on the object's geometry and computer-aided design (CAD) model. This selection process strategically balances the need for measurements aligned with the part's long edges against the need for maintaining a diverse set of overall measurements. Through simulations, we demonstrate that our algorithm significantly reduces the number of projections needed to achieve high-quality reconstructions compared to traditional methods.

Read more

7/19/2024

Total Score

0

Accurate Patient Alignment without Unnecessary Imaging Dose via Synthesizing Patient-specific 3D CT Images from 2D kV Images

Yuzhen Ding, Jason M. Holmes, Hongying Feng, Baoxin Li, Lisa A. McGee, Jean-Claude M. Rwigema, Sujay A. Vora, Daniel J. Ma, Robert L. Foote, Samir H. Patel, Wei Liu

In radiotherapy, 2D orthogonally projected kV images are used for patient alignment when 3D-on-board imaging(OBI) unavailable. But tumor visibility is constrained due to the projection of patient's anatomy onto a 2D plane, potentially leading to substantial setup errors. In treatment room with 3D-OBI such as cone beam CT(CBCT), the field of view(FOV) of CBCT is limited with unnecessarily high imaging dose, thus unfavorable for pediatric patients. A solution to this dilemma is to reconstruct 3D CT from kV images obtained at the treatment position. Here, we propose a dual-models framework built with hierarchical ViT blocks. Unlike a proof-of-concept approach, our framework considers kV images as the solo input and can synthesize accurate, full-size 3D CT in real time(within milliseconds). We demonstrate the feasibility of the proposed approach on 10 patients with head and neck (H&N) cancer using image quality(MAE: 97%) and patient position uncertainty(shift error: <0.4mm). The proposed framework can generate accurate 3D CT faithfully mirroring real-time patient position, thus significantly improving patient setup accuracy, keeping imaging dose minimum, and maintaining treatment veracity.

Read more

5/31/2024

An efficient method to automate tooth identification and 3D bounding box extraction from Cone Beam CT Images
Total Score

0

An efficient method to automate tooth identification and 3D bounding box extraction from Cone Beam CT Images

Ignacio Garrido Botella, Ignacio Arranz 'Agueda, Juan Carlos Armenteros Carmona, Oleg Vorontsov, Fernando Bay'on Robledo, Evgeny Solovykh, Obrubov Aleksandr Andreevich, Adri'an Alonso Barriuso

Accurate identification, localization, and segregation of teeth from Cone Beam Computed Tomography (CBCT) images are essential for analyzing dental pathologies. Modeling an individual tooth can be challenging and intricate to accomplish, especially when fillings and other restorations introduce artifacts. This paper proposes a method for automatically detecting, identifying, and extracting teeth from CBCT images. Our approach involves dividing the three-dimensional images into axial slices for image detection. Teeth are pinpointed and labeled using a single-stage object detector. Subsequently, bounding boxes are delineated and identified to create three-dimensional representations of each tooth. The proposed solution has been successfully integrated into the dental analysis tool Dentomo.

Read more

7/11/2024