A Patient-Specific Framework for Autonomous Spinal Fixation via a Steerable Drilling Robot

Read original: arXiv:2405.17606 - Published 7/9/2024 by Susheela Sharma, Sarah Go, Zeynep Yakay, Yash Kulkarni, Siddhartha Kapuria, Jordan P. Amadio, Mohsen Khadem, Nassir Navab, Farshid Alambeigi
Total Score

0

A Patient-Specific Framework for Autonomous Spinal Fixation via a Steerable Drilling Robot

Sign in to get full access

or

If you already have an account, we'll log you in

Overview

  • This research paper presents a patient-specific framework for autonomous spinal fixation using a steerable drilling robot.
  • The framework aims to enable precise and personalized surgical interventions for spinal conditions, improving patient outcomes.
  • Key aspects include patient-specific surgical planning, robotic guidance, and autonomous drilling capabilities.

Plain English Explanation

The paper describes a new system that uses a special robot to help surgeons with spinal surgery. Spinal surgery can be very complex and precise, so this robot is designed to assist the surgeon in a personalized way for each patient.

The system starts by creating a detailed 3D model of the patient's spine using medical imaging. This aligns with the work discussed in "Towards Biomechanical Evaluation of Transformative Additively Manufactured Flexible Spinal Implants". The robot is then programmed with this information to plan the best approach for the surgery.

During the actual operation, the robot guides the surgical tools precisely to the correct locations on the spine. Similar to the "Open-Source High-Precision Autonomous Suturing Framework", the robot can perform some of the drilling and implant placement autonomously, reducing the manual work required from the surgeon.

This personalized, robotic-assisted approach aims to make spinal surgeries faster, more accurate, and ultimately better for the patient's recovery and long-term health. The "Visual Attention-Based Cognitive Human-Robot Collaboration" research explores related concepts of improving human-robot teamwork in medical settings.

Technical Explanation

The paper presents a patient-specific framework for autonomous spinal fixation using a steerable drilling robot. The key components include:

  1. Patient-Specific Surgical Planning: The system creates a detailed 3D model of the patient's spinal anatomy based on medical imaging data. This allows for personalized planning of the optimal surgical approach and trajectory.

  2. Robotic Guidance: The robot is programmed with the patient-specific plan and uses its steerable drilling capabilities to precisely guide the surgical tools to the target locations on the spine. This builds on the "Spatial Spinal Fixation: A Transformative Approach Using Unique Robotic Guidance" research.

  3. Autonomous Drilling: The robot can autonomously perform the drilling and implant placement steps, reducing the manual work required from the surgeon. The "Safe Start Regions for Medical Steerable Needle Automation" research explores related concepts of improving the safety and autonomy of surgical robots.

The authors validate the framework through experiments and simulations, demonstrating its potential to improve the accuracy, efficiency, and personalization of spinal fixation procedures.

Critical Analysis

The paper presents a promising approach to improving spinal surgery, but there are a few potential limitations and areas for further research:

  • The system relies on accurate 3D modeling of the patient's spine, which may be challenging in some cases due to variations in anatomy or imaging quality.
  • The autonomous drilling capabilities of the robot may need to be further refined to ensure consistent and reliable performance in a clinical setting.
  • The paper does not address potential issues around patient acceptance or integration of the robotic system into existing surgical workflows.

Additionally, the authors could explore ways to further enhance the system's adaptability and responsiveness to intraoperative changes or unexpected situations.

Conclusion

The patient-specific framework for autonomous spinal fixation using a steerable drilling robot represents a significant advancement in medical robotics. By integrating personalized surgical planning, robotic guidance, and autonomous drilling, this system has the potential to enhance the precision, efficiency, and patient outcomes of spinal fixation procedures.

As the field of medical robotics continues to evolve, this research highlights the importance of developing customized, adaptable solutions that can seamlessly integrate with the unique needs and requirements of each patient. Further research and clinical validation will be crucial to realizing the full benefits of this transformative approach.



This summary was produced with help from an AI and may contain inaccuracies - check out the links to read the original source documents!

Follow @aimodelsfyi on 𝕏 →

Related Papers

A Patient-Specific Framework for Autonomous Spinal Fixation via a Steerable Drilling Robot
Total Score

0

A Patient-Specific Framework for Autonomous Spinal Fixation via a Steerable Drilling Robot

Susheela Sharma, Sarah Go, Zeynep Yakay, Yash Kulkarni, Siddhartha Kapuria, Jordan P. Amadio, Mohsen Khadem, Nassir Navab, Farshid Alambeigi

In this paper, with the goal of enhancing the minimally invasive spinal fixation procedure in osteoporotic patients, we propose a first-of-its-kind image-guided robotic framework for performing an autonomous and patient-specific procedure using a unique concentric tube steerable drilling robot (CT-SDR). Particularly, leveraging a CT-SDR, we introduce the concept of J-shape drilling based on a pre-operative trajectory planned in CT scan of a patient followed by appropriate calibration, registration, and navigation steps to safely execute this trajectory in real-time using our unique robotic setup. To thoroughly evaluate the performance of our framework, we performed several experiments on two different vertebral phantoms designed based on CT scan of real patients.

Read more

7/9/2024

Towards an Autonomous Minimally Invasive Spinal Fixation Surgery Using a Concentric Tube Steerable Drilling Robot
Total Score

0

Towards an Autonomous Minimally Invasive Spinal Fixation Surgery Using a Concentric Tube Steerable Drilling Robot

Susheela Sharma, Sarah Go, Jeff Bonyun, Jordan P. Amadio, Mohsen Khadem, Farshid Alambeigi

Towards performing a realistic autonomous minimally invasive spinal fixation procedure, in this paper, we introduce a unique robotic drilling system utilizing a concentric tube steerable drilling robot (CT-SDR) integrated with a seven degree-of-freedom robotic manipulator. The CT-SDR in integration with the robotic arm enables creating precise J-shape trajectories enabling access to the areas within the vertebral body that currently are not accessible utilizing existing rigid instruments. To ensure safety and accuracy of the autonomous drilling procedure, we also performed required calibration procedures. The performance of the proposed robotic system and the calibration steps were thoroughly evaluated by performing various drilling experiments on simulated Sawbone samples.

Read more

5/31/2024

Spatial Spinal Fixation: A Transformative Approach Using a Unique Robot-Assisted Steerable Drilling System and Flexible Pedicle Screw
Total Score

0

Spatial Spinal Fixation: A Transformative Approach Using a Unique Robot-Assisted Steerable Drilling System and Flexible Pedicle Screw

Susheela Sharma, Yash Kulkarni, Sarah Go, Jeff Bonyun, Jordan P. Amadio, Maryam Tilton, Mohsen Khadem, Farshid Alambeigi

Spinal fixation procedures are currently limited by the rigidity of the existing instruments and pedicle screws leading to fixation failures and rigid pedicle screw pull out. Leveraging our recently developed Concentric Tube Steerable Drilling Robot (CT-SDR) in integration with a robotic manipulator, to address the aforementioned issue, here we introduce the transformative concept of Spatial Spinal Fixation (SSF) using a unique Flexible Pedicle Screw (FPS). The proposed SSF procedure enables planar and out-of-plane placement of the FPS throughout the full volume of the vertebral body. In other words, not only does our fixation system provide the option of drilling in-plane and out-of-plane trajectories, it also enables implanting the FPS inside linear (represented by an I-shape) and/or non-linear (represented by J-shape) trajectories. To thoroughly evaluate the functionality of our proposed robotic system and the SSF procedure, we have performed various experiments by drilling different I-J and J-J drilling trajectory pairs into our custom-designed L3 vertebral phantoms and analyzed the accuracy of the procedure using various metrics.

Read more

7/9/2024

Towards Biomechanical Evaluation of a Transformative Additively Manufactured Flexible Pedicle Screw for Robotic Spinal Fixation
Total Score

0

Towards Biomechanical Evaluation of a Transformative Additively Manufactured Flexible Pedicle Screw for Robotic Spinal Fixation

Yash Kulkarni, Susheela Sharma, Jordan P. Amadio, Farshid Alambeigi

Vital for spinal fracture treatment, pedicle screw fixation is the gold standard for spinal fixation procedures. Nevertheless, due to the screw pullout and loosening issues, this surgery often fails to be effective for patients suffering from osteoporosis (i.e., having low bone mineral density). These failures can be attributed to the rigidity of existing drilling instruments and pedicle screws forcing clinicians to place these implants into the osteoporotic regions of the vertebral body. To address this critical issue, we have developed a steerable drilling robotic system and evaluated its performance in drilling various J- and U-shape trajectories. Complementary to this robotic system, in this paper, we propose design, additive manufacturing, and biomechanical evaluation of a transformative flexible pedicle screw (FPS) that can be placed in pre-drilled straight and curved trajectories. To evaluate the performance of the proposed flexible implant, we designed and fabricated two different types of FPSs using the direct metal laser sintering (DMLS) process. Utilizing our unique experimental setup and ASTM standards, we then performed various pullout experiments on these FPSs to evaluate and analyze their biomechanical performance implanted in straight trajectories.

Read more