Safe Start Regions for Medical Steerable Needle Automation

Read original: arXiv:2404.08558 - Published 4/15/2024 by Janine Hoelscher, Inbar Fried, Spiros Tsalikis, Jason Akulian, Robert J. Webster III, Ron Alterovitz
Total Score

0

Safe Start Regions for Medical Steerable Needle Automation

Sign in to get full access

or

If you already have an account, we'll log you in

Overview

  • This paper explores the concept of "safe start regions" for medical steerable needles, which are important for the automation and safe operation of these devices in surgical procedures.
  • Steerable needles can be challenging to control, so defining safe starting points for their motion is crucial to ensure they can reach the desired target without harming the patient.
  • The paper presents a method for determining these safe start regions and evaluates it through simulations and experiments.

Plain English Explanation

Medical needles that can bend and steer, known as "steerable needles," are being developed to improve surgical procedures. These needles allow doctors to more precisely target specific areas inside the body. However, controlling the motion of steerable needles can be tricky, as they don't move in a simple straight line like a regular needle.

To help make steerable needles easier and safer to use, this research looks at defining "safe start regions" - areas where the needle can begin its motion without risking harm to the patient. By knowing where the needle can safely start, doctors can plan the needle's path more effectively and avoid complications.

The researchers developed a method to calculate these safe start regions for steerable needles. They tested their approach through computer simulations and real-world experiments to see how well it worked. The results show this technique can reliably identify safe starting points for steerable needles, which is an important step towards making these advanced surgical tools more practical and widely usable.

Technical Explanation

The paper presents a method for determining "safe start regions" for medical steerable needles, which are critical for the automation and safe operation of these devices in surgical procedures.

The key technical aspects include:

  • Modeling the kinematics and constraints of steerable needles to understand their range of motion and potential risks.
  • Developing an algorithm to compute safe start regions that account for obstacles, anatomical structures, and the needle's kinematic limitations.
  • Validating the approach through simulations that assess the size and feasibility of the computed safe start regions.
  • Demonstrating the method's effectiveness in real-world experiments using a steerable needle robotic system.

The proposed safe start region determination process enables more reliable and automated planning of steerable needle trajectories, which is an important step towards making these advanced surgical tools more practical and widely usable.

Critical Analysis

The paper provides a solid technical foundation for defining safe start regions for steerable needles, but there are a few potential limitations and areas for further research:

  • The simulations and experiments were conducted in relatively simple, controlled environments. More testing is needed to evaluate the approach's robustness in realistic, complex surgical settings with anatomical obstacles and uncertainties.
  • The safe start region computations rely on accurate knowledge of the needle's kinematic model and environment. In practice, there may be uncertainties or errors in these inputs that could affect the validity of the calculated safe regions.
  • The paper focuses on planar motion of the needle, but real-world procedures often involve 3D motion. Extending the safe start region methodology to fully 3D scenarios could be an important next step.

Overall, this research represents a valuable contribution towards safer and more automated use of steerable needles in medical procedures. Continued work to address the limitations and further validate the approach in realistic clinical contexts will be important for translating these findings into practical surgical applications.

Conclusion

This paper presents a method for determining "safe start regions" for medical steerable needles, which is a critical capability for the automation and safe operation of these advanced surgical instruments. By calculating regions where the needle can begin its motion without risking harm to the patient, the approach enables more reliable and efficient planning of steerable needle trajectories.

The technical details of the safe start region computation, as well as the validation through simulations and real-world experiments, demonstrate the feasibility and effectiveness of this technique. While some limitations and areas for further research remain, this work represents an important step forward in making steerable needles a more practical and widely usable tool for minimally invasive medical procedures.



This summary was produced with help from an AI and may contain inaccuracies - check out the links to read the original source documents!

Follow @aimodelsfyi on 𝕏 →

Related Papers

Safe Start Regions for Medical Steerable Needle Automation
Total Score

0

Safe Start Regions for Medical Steerable Needle Automation

Janine Hoelscher, Inbar Fried, Spiros Tsalikis, Jason Akulian, Robert J. Webster III, Ron Alterovitz

Steerable needles are minimally invasive devices that enable novel medical procedures by following curved paths to avoid critical anatomical obstacles. Planning algorithms can be used to find a steerable needle motion plan to a target. Deployment typically consists of a physician manually inserting the steerable needle into tissue at the motion plan's start pose and handing off control to a robot, which then autonomously steers it to the target along the plan. The handoff between human and robot is critical for procedure success, as even small deviations from the start pose change the steerable needle's workspace and there is no guarantee that the target will still be reachable. We introduce a metric that evaluates the robustness to such start pose deviations. When measuring this robustness to deviations, we consider the tradeoff between being robust to changes in position versus changes in orientation. We evaluate our metric through simulation in an abstract, a liver, and a lung planning scenario. Our evaluation shows that our metric can be combined with different motion planners and that it efficiently determines large, safe start regions.

Read more

4/15/2024

🤿

Total Score

0

Nerve Block Target Localization and Needle Guidance for Autonomous Robotic Ultrasound Guided Regional Anesthesia

Abhishek Tyagi, Abhay Tyagi, Manpreet Kaur, Richa Aggarwal, Kapil D. Soni, Jayanthi Sivaswamy, Anjan Trikha

Visual servoing for the development of autonomous robotic systems capable of administering UltraSound (US) guided regional anesthesia requires real-time segmentation of nerves, needle tip localization and needle trajectory extrapolation. First, we recruited 227 patients to build a large dataset of 41,000 anesthesiologist annotated images from US videos of brachial plexus nerves and developed models to localize nerves in the US images. Generalizability of the best suited model was tested on the datasets constructed from separate US scanners. Using these nerve segmentation predictions, we define automated anesthesia needle targets by fitting an ellipse to the nerve contours. Next, we developed an image analysis tool to guide the needle toward their targets. For the segmentation of the needle, a natural RGB pre-trained neural network was first fine-tuned on a large US dataset for domain transfer and then adapted for the needle using a small dataset. The segmented needle trajectory angle is calculated using Radon transformation and the trajectory is extrapolated from the needle tip. The intersection of the extrapolated trajectory with the needle target guides the needle navigation for drug delivery. The needle trajectory average error was within acceptable range of 5 mm as per experienced anesthesiologists. The entire dataset has been released publicly for further study by the research community at https://github.com/Regional-US/

Read more

9/14/2024

A Patient-Specific Framework for Autonomous Spinal Fixation via a Steerable Drilling Robot
Total Score

0

A Patient-Specific Framework for Autonomous Spinal Fixation via a Steerable Drilling Robot

Susheela Sharma, Sarah Go, Zeynep Yakay, Yash Kulkarni, Siddhartha Kapuria, Jordan P. Amadio, Mohsen Khadem, Nassir Navab, Farshid Alambeigi

In this paper, with the goal of enhancing the minimally invasive spinal fixation procedure in osteoporotic patients, we propose a first-of-its-kind image-guided robotic framework for performing an autonomous and patient-specific procedure using a unique concentric tube steerable drilling robot (CT-SDR). Particularly, leveraging a CT-SDR, we introduce the concept of J-shape drilling based on a pre-operative trajectory planned in CT scan of a patient followed by appropriate calibration, registration, and navigation steps to safely execute this trajectory in real-time using our unique robotic setup. To thoroughly evaluate the performance of our framework, we performed several experiments on two different vertebral phantoms designed based on CT scan of real patients.

Read more

7/9/2024

👁️

Total Score

0

A Fourier-enhanced multi-modal 3D small object optical mark recognition and positioning method for percutaneous abdominal puncture surgical navigation

Zezhao Guo (College of information and Engineering, Hebei GEO University), Yanzhong Guo (Beijing Yingrui Pioneer Medical Technology Co., Ltd), Zhanfang Zhao (College of information and Engineering, Hebei GEO University)

Navigation for thoracoabdominal puncture surgery is used to locate the needle entry point on the patient's body surface. The traditional reflective ball navigation method is difficult to position the needle entry point on the soft, irregular, smooth chest and abdomen. Due to the lack of clear characteristic points on the body surface using structured light technology, it is difficult to identify and locate arbitrary needle insertion points. Based on the high stability and high accuracy requirements of surgical navigation, this paper proposed a novel method, a muti-modal 3D small object medical marker detection method, which identifies the center of a small single ring as the needle insertion point. Moreover, this novel method leverages Fourier transform enhancement technology to augment the dataset, enrich image details, and enhance the network's capability. The method extracts the Region of Interest (ROI) of the feature image from both enhanced and original images, followed by generating a mask map. Subsequently, the point cloud of the ROI from the depth map is obtained through the registration of ROI point cloud contour fitting. In addition, this method employs Tukey loss for optimal precision. The experimental results show this novel method proposed in this paper not only achieves high-precision and high-stability positioning, but also enables the positioning of any needle insertion point.

Read more