A Personalized Zero-Shot ECG Arrhythmia Monitoring System: From Sparse Representation Based Domain Adaption to Energy Efficient Abnormal Beat Detection for Practical ECG Surveillance

Read original: arXiv:2207.07089 - Published 8/23/2024 by Mehmet Yamac{c}, Mert Duman, .Ilke Adal{i}ou{g}lu, Serkan Kiranyaz, Moncef Gabbouj
Total Score

0

🔎

Sign in to get full access

or

If you already have an account, we'll log you in

Overview

  • This paper proposes a low-cost and highly accurate ECG-monitoring system for personalized early arrhythmia detection in wearable mobile sensors.
  • It introduces a sparse representation-based domain adaptation technique to enable zero-shot learning without the need for abnormal heartbeat data from the new user.
  • The proposed ensemble classifier combines null space analysis and domain adaptation to achieve high accuracy for personalized arrhythmia detection.

Plain English Explanation

The paper presents a new approach for personalizing ECG monitoring systems to detect heart rhythm abnormalities (arrhythmias) early on. Existing methods require both normal and abnormal heartbeat data to train a classifier for a specific user. However, in a real-world scenario where the system is embedded in a wearable device, such training data may not be available, especially for healthy individuals with no known heart issues.

To address this, the researchers propose using a "null space analysis" technique to simplify the classification process without sacrificing accuracy. They also introduce a "domain adaptation" method that allows the system to use abnormal and normal heartbeat data from other users to train the classifier for a new user, instead of requiring the new user's own abnormal data.

By combining these innovations, the researchers develop an ensemble classifier that can achieve very high accuracy (98.2%) and performance (92.8% F1-score) for personalized arrhythmia detection, even when no abnormal data is available for the new user. This zero-shot learning approach could enable the development of energy-efficient, personalized ECG monitoring systems for wearable devices.

Technical Explanation

The paper proposes a three-part solution for personalized arrhythmia detection in wearable ECG monitoring systems:

  1. Null Space Analysis: The researchers use sparse dictionary learning to model the "healthy" signal space of a user's ECG data. They then investigate how a simple null space projection or regularized least squares-based classification can reduce computational complexity without sacrificing detection accuracy, compared to more complex sparse representation-based classification.

  2. Domain Adaptation: To enable zero-shot learning, the researchers introduce a sparse representation-based domain adaptation technique. This allows them to project other users' abnormal and normal ECG signals onto the new user's signal space, enabling the training of a dedicated classifier without any of the new user's abnormal heartbeat data.

  3. Ensemble Classifier: By combining the null space analysis and domain adaptation techniques, the researchers develop an ensemble classifier that further improves the performance of the personalized arrhythmia detection system.

The researchers evaluate their approach on the benchmark MIT-BIH ECG dataset and demonstrate that their domain adaptation-based training data generator, when used with a simple 1D CNN classifier, outperforms prior work by a significant margin. The final ensemble classifier achieves an average accuracy of 98.2% and an F1-score of 92.8% for personalized arrhythmia detection.

Critical Analysis

The paper presents a comprehensive solution for the challenge of personalized ECG monitoring without requiring abnormal heartbeat data from the new user. The proposed techniques, especially the domain adaptation approach, are novel and well-designed to address this real-world constraint.

However, the paper does not provide much discussion on the potential limitations or caveats of the proposed system. For example, it is unclear how the system would perform with noisy or incomplete ECG data, which can be common in wearable devices. Additionally, the paper does not explore the adaptability of the system to handle changes in a user's ECG patterns over time.

Further research could also investigate the generalizability of the domain adaptation technique to other types of physiological signals beyond ECG, as well as its potential application in other healthcare monitoring scenarios where labeled data for a new user may be scarce.

Conclusion

This paper presents a promising solution for personalized, early arrhythmia detection in wearable ECG monitoring systems. By leveraging null space analysis and sparse representation-based domain adaptation, the researchers have developed an ensemble classifier that can achieve high accuracy and performance without requiring abnormal heartbeat data from the new user.

This zero-shot learning approach could enable the development of energy-efficient, personalized ECG monitoring systems that can be seamlessly integrated into wearable devices. The insights and techniques from this research have the potential to significantly improve the accessibility and effectiveness of remote cardiac health monitoring, benefiting both individuals and the broader healthcare system.



This summary was produced with help from an AI and may contain inaccuracies - check out the links to read the original source documents!

Follow @aimodelsfyi on 𝕏 →

Related Papers

🔎

Total Score

0

A Personalized Zero-Shot ECG Arrhythmia Monitoring System: From Sparse Representation Based Domain Adaption to Energy Efficient Abnormal Beat Detection for Practical ECG Surveillance

Mehmet Yamac{c}, Mert Duman, .Ilke Adal{i}ou{g}lu, Serkan Kiranyaz, Moncef Gabbouj

This paper proposes a low-cost and highly accurate ECG-monitoring system intended for personalized early arrhythmia detection for wearable mobile sensors. Earlier supervised approaches for personalized ECG monitoring require both abnormal and normal heartbeats for the training of the dedicated classifier. However, in a real-world scenario where the personalized algorithm is embedded in a wearable device, such training data is not available for healthy people with no cardiac disorder history. In this study, (i) we propose a null space analysis on the healthy signal space obtained via sparse dictionary learning, and investigate how a simple null space projection or alternatively regularized least squares-based classification methods can reduce the computational complexity, without sacrificing the detection accuracy, when compared to sparse representation-based classification. (ii) Then we introduce a sparse representation-based domain adaptation technique in order to project other existing users' abnormal and normal signals onto the new user's signal space, enabling us to train the dedicated classifier without having any abnormal heartbeat of the new user. Therefore, zero-shot learning can be achieved without the need for synthetic abnormal heartbeat generation. An extensive set of experiments performed on the benchmark MIT-BIH ECG dataset shows that when this domain adaptation-based training data generator is used with a simple 1-D CNN classifier, the method outperforms the prior work by a significant margin. (iii) Then, by combining (i) and (ii), we propose an ensemble classifier that further improves the performance. This approach for zero-shot arrhythmia detection achieves an average accuracy level of 98.2% and an F1-Score of 92.8%. Finally, a personalized energy-efficient ECG monitoring scheme is proposed using the above-mentioned innovations.

Read more

8/23/2024

Anomaly Detection in Electrocardiograms: Advancing Clinical Diagnosis Through Self-Supervised Learning
Total Score

0

Anomaly Detection in Electrocardiograms: Advancing Clinical Diagnosis Through Self-Supervised Learning

Aofan Jiang, Chaoqin Huang, Qing Cao, Yuchen Xu, Zi Zeng, Kang Chen, Ya Zhang, Yanfeng Wang

The electrocardiogram (ECG) is an essential tool for diagnosing heart disease, with computer-aided systems improving diagnostic accuracy and reducing healthcare costs. Despite advancements, existing systems often miss rare cardiac anomalies that could be precursors to serious, life-threatening issues or alterations in the cardiac macro/microstructure. We address this gap by focusing on self-supervised anomaly detection (AD), training exclusively on normal ECGs to recognize deviations indicating anomalies. We introduce a novel self-supervised learning framework for ECG AD, utilizing a vast dataset of normal ECGs to autonomously detect and localize cardiac anomalies. It proposes a novel masking and restoration technique alongside a multi-scale cross-attention module, enhancing the model's ability to integrate global and local signal features. The framework emphasizes accurate localization of anomalies within ECG signals, ensuring the method's clinical relevance and reliability. To reduce the impact of individual variability, the approach further incorporates crucial patient-specific information from ECG reports, such as age and gender, thus enabling accurate identification of a broad spectrum of cardiac anomalies, including rare ones. Utilizing an extensive dataset of 478,803 ECG graphic reports from real-world clinical practice, our method has demonstrated exceptional effectiveness in AD across all tested conditions, regardless of their frequency of occurrence, significantly outperforming existing models. It achieved superior performance metrics, including an AUROC of 91.2%, an F1 score of 83.7%, a sensitivity rate of 84.2%, a specificity of 83.0%, and a precision of 75.6% with a fixed recall rate of 90%. It has also demonstrated robust localization capabilities, with an AUROC of 76.5% and a Dice coefficient of 65.3% for anomaly localization.

Read more

4/9/2024

🏷️

Total Score

0

A Tiny Transformer for Low-Power Arrhythmia Classification on Microcontrollers

Paola Busia, Matteo Antonio Scrugli, Victor Jean-Baptiste Jung, Luca Benini, Paolo Meloni

Wearable systems for the continuous and real-time monitoring of cardiovascular diseases are becoming widespread and valuable assets in diagnosis and therapy. A promising approach for real-time analysis of the electrocardiographic (ECG) signal and the detection of heart conditions, such as arrhythmia, is represented by the transformer machine learning model. Transformers are powerful models for the classification of time series, although efficient implementation in the wearable domain raises significant design challenges, to combine adequate accuracy and a suitable complexity. In this work, we present a tiny transformer model for the analysis of the ECG signal, requiring only 6k parameters and reaching 98.97% accuracy in the recognition of the 5 most common arrhythmia classes from the MIT-BIH Arrhythmia database, assessed considering 8-bit integer inference as required for efficient execution on low-power microcontroller-based devices. We explored an augmentation-based training approach for improving the robustness against electrode motion artifacts noise, resulting in a worst-case post-deployment performance assessment of 98.36% accuracy. Suitability for wearable monitoring solutions is finally demonstrated through efficient deployment on the parallel ultra-low-power GAP9 processor, where inference execution requires 4.28ms and 0.09mJ.

Read more

6/24/2024

Zero-Shot ECG Classification with Multimodal Learning and Test-time Clinical Knowledge Enhancement
Total Score

0

Zero-Shot ECG Classification with Multimodal Learning and Test-time Clinical Knowledge Enhancement

Che Liu, Zhongwei Wan, Cheng Ouyang, Anand Shah, Wenjia Bai, Rossella Arcucci

Electrocardiograms (ECGs) are non-invasive diagnostic tools crucial for detecting cardiac arrhythmic diseases in clinical practice. While ECG Self-supervised Learning (eSSL) methods show promise in representation learning from unannotated ECG data, they often overlook the clinical knowledge that can be found in reports. This oversight and the requirement for annotated samples for downstream tasks limit eSSL's versatility. In this work, we address these issues with the Multimodal ECG Representation Learning (MERL}) framework. Through multimodal learning on ECG records and associated reports, MERL is capable of performing zero-shot ECG classification with text prompts, eliminating the need for training data in downstream tasks. At test time, we propose the Clinical Knowledge Enhanced Prompt Engineering (CKEPE) approach, which uses Large Language Models (LLMs) to exploit external expert-verified clinical knowledge databases, generating more descriptive prompts and reducing hallucinations in LLM-generated content to boost zero-shot classification. Based on MERL, we perform the first benchmark across six public ECG datasets, showing the superior performance of MERL compared against eSSL methods. Notably, MERL achieves an average AUC score of 75.2% in zero-shot classification (without training data), 3.2% higher than linear probed eSSL methods with 10% annotated training data, averaged across all six datasets.

Read more

5/7/2024