A Tiny Transformer for Low-Power Arrhythmia Classification on Microcontrollers

Read original: arXiv:2402.10748 - Published 6/24/2024 by Paola Busia, Matteo Antonio Scrugli, Victor Jean-Baptiste Jung, Luca Benini, Paolo Meloni
Total Score

0

🏷️

Sign in to get full access

or

If you already have an account, we'll log you in

Overview

  • Wearable systems for continuous and real-time monitoring of cardiovascular diseases are becoming more widespread and valuable for diagnosis and therapy.
  • One promising approach for real-time ECG signal analysis and heart condition detection is the use of transformer machine learning models.
  • Transformers are powerful for time series classification, but efficient implementation in wearable devices poses design challenges to balance accuracy and complexity.

Plain English Explanation

Wearable devices that can continuously monitor a person's heart health are becoming more common and useful for doctors to diagnose and treat cardiovascular diseases. One effective way to analyze the electrical signals from the heart (called an ECG) and detect problems like abnormal heart rhythms (arrhythmia) is to use a type of machine learning model called a transformer.

Transformers are very good at classifying time-series data, like the ECG signal. However, making transformers work well on low-power wearable devices requires carefully balancing the model's accuracy and its complexity (the number of parameters it uses). This paper presents a small transformer model that can accurately detect the 5 most common types of arrhythmia using only 6,000 parameters.

The researchers also found a way to train the model to be more robust against noise from motion artifacts (movement) on the electrodes, which can affect the ECG signal. This allows the model to maintain high accuracy even after it's deployed on a wearable device.

Finally, the paper shows that this tiny transformer model can run efficiently on a low-power microcontroller chip, taking just 4.28 milliseconds and 0.09 millijoules of energy to make a prediction. This makes it well-suited for integration into wearable heart monitoring solutions.

Technical Explanation

This paper presents a tiny transformer model for the real-time analysis of ECG signals and the detection of common heart arrhythmias. Transformers are powerful machine learning models that have shown strong performance on time series classification tasks, like ECG analysis. However, deploying transformers on low-power wearable devices requires careful optimization to balance accuracy and complexity.

The researchers developed a transformer model with only 6,000 parameters that can achieve 98.97% accuracy in recognizing the 5 most common arrhythmia classes from the MIT-BIH Arrhythmia database. This was assessed using 8-bit integer inference, which is important for efficient execution on microcontroller-based wearable devices.

To improve the model's robustness against motion artifact noise, the researchers explored an augmentation-based training approach. This resulted in a worst-case post-deployment performance of 98.36% accuracy, demonstrating the model's suitability for real-world wearable monitoring.

The paper also shows that this tiny transformer model can be efficiently deployed on the parallel ultra-low-power GAP9 processor, with an inference time of just 4.28ms and an energy consumption of 0.09mJ. This highlights the potential of the proposed approach for integration into practical wearable solutions for continuous heart health monitoring.

Critical Analysis

The paper presents a promising approach for building efficient transformer-based models for ECG analysis on wearable devices. The key strengths are the small model size, high accuracy, and efficient deployment on low-power hardware.

However, the paper does not discuss the model's performance on more diverse or challenging ECG datasets beyond the MIT-BIH Arrhythmia database. It would be valuable to see how the model generalizes to different populations, sensor placements, or noise conditions.

Additionally, the paper does not provide a detailed comparison to other state-of-the-art ECG classification methods, such as those using convolutional neural networks or recurrent neural networks. Comparing the transformer model's performance, efficiency, and robustness to these other approaches would help contextualize the contributions.

It would also be insightful to see an analysis of the transformer model's attention patterns and internal representations to gain deeper insights into how it is able to effectively classify ECG signals. This type of interpretability analysis could help inform future improvements to the model architecture or training.

Overall, this paper presents a valuable step towards efficient ECG classification on wearable devices, but further research is needed to fully understand the capabilities and limitations of the approach.

Conclusion

This paper introduces a tiny transformer model for real-time ECG signal analysis and arrhythmia detection, designed for efficient execution on low-power wearable devices. The model achieves high accuracy on the common arrhythmia classes while using only 6,000 parameters, and can be deployed with low latency and energy consumption.

The researchers' focus on balancing model complexity and accuracy, as well as improving robustness to motion artifact noise, makes this work an important contribution towards the integration of advanced machine learning into practical wearable health monitoring solutions. Further exploration of the model's broader capabilities and comparisons to alternative approaches could help advance the field of efficient, accurate, and interpretable ECG analysis on resource-constrained platforms.



This summary was produced with help from an AI and may contain inaccuracies - check out the links to read the original source documents!

Follow @aimodelsfyi on 𝕏 →

Related Papers

🏷️

Total Score

0

A Tiny Transformer for Low-Power Arrhythmia Classification on Microcontrollers

Paola Busia, Matteo Antonio Scrugli, Victor Jean-Baptiste Jung, Luca Benini, Paolo Meloni

Wearable systems for the continuous and real-time monitoring of cardiovascular diseases are becoming widespread and valuable assets in diagnosis and therapy. A promising approach for real-time analysis of the electrocardiographic (ECG) signal and the detection of heart conditions, such as arrhythmia, is represented by the transformer machine learning model. Transformers are powerful models for the classification of time series, although efficient implementation in the wearable domain raises significant design challenges, to combine adequate accuracy and a suitable complexity. In this work, we present a tiny transformer model for the analysis of the ECG signal, requiring only 6k parameters and reaching 98.97% accuracy in the recognition of the 5 most common arrhythmia classes from the MIT-BIH Arrhythmia database, assessed considering 8-bit integer inference as required for efficient execution on low-power microcontroller-based devices. We explored an augmentation-based training approach for improving the robustness against electrode motion artifacts noise, resulting in a worst-case post-deployment performance assessment of 98.36% accuracy. Suitability for wearable monitoring solutions is finally demonstrated through efficient deployment on the parallel ultra-low-power GAP9 processor, where inference execution requires 4.28ms and 0.09mJ.

Read more

6/24/2024

🏷️

Total Score

0

Masked Transformer for Electrocardiogram Classification

Ya Zhou, Xiaolin Diao, Yanni Huo, Yang Liu, Xiaohan Fan, Wei Zhao

Electrocardiogram (ECG) is one of the most important diagnostic tools in clinical applications. With the advent of advanced algorithms, various deep learning models have been adopted for ECG tasks. However, the potential of Transformer for ECG data has not been fully realized, despite their widespread success in computer vision and natural language processing. In this work, we present Masked Transformer for ECG classification (MTECG), a simple yet effective method which significantly outperforms recent state-of-the-art algorithms in ECG classification. Our approach adapts the image-based masked autoencoders to self-supervised representation learning from ECG time series. We utilize a lightweight Transformer for the encoder and a 1-layer Transformer for the decoder. The ECG signal is split into a sequence of non-overlapping segments along the time dimension, and learnable positional embeddings are added to preserve the sequential information. We construct the Fuwai dataset comprising 220,251 ECG recordings with a broad range of diagnoses, annotated by medical experts, to explore the potential of Transformer. A strong pre-training and fine-tuning recipe is proposed from the empirical study. The experiments demonstrate that the proposed method increases the macro F1 scores by 3.4%-27.5% on the Fuwai dataset, 9.9%-32.0% on the PTB-XL dataset, and 9.4%-39.1% on a multicenter dataset, compared to the alternative methods. We hope that this study could direct future research on the application of Transformer to more ECG tasks.

Read more

4/24/2024

Deciphering Heartbeat Signatures: A Vision Transformer Approach to Explainable Atrial Fibrillation Detection from ECG Signals
Total Score

0

Deciphering Heartbeat Signatures: A Vision Transformer Approach to Explainable Atrial Fibrillation Detection from ECG Signals

Aruna Mohan, Danne Elbers, Or Zilbershot, Fatemeh Afghah, David Vorchheimer

Remote patient monitoring based on wearable single-lead electrocardiogram (ECG) devices has significant potential for enabling the early detection of heart disease, especially in combination with artificial intelligence (AI) approaches for automated heart disease detection. There have been prior studies applying AI approaches based on deep learning for heart disease detection. However, these models are yet to be widely accepted as a reliable aid for clinical diagnostics, in part due to the current black-box perception surrounding many AI algorithms. In particular, there is a need to identify the key features of the ECG signal that contribute toward making an accurate diagnosis, thereby enhancing the interpretability of the model. In the present study, we develop a vision transformer approach to identify atrial fibrillation based on single-lead ECG data. A residual network (ResNet) approach is also developed for comparison with the vision transformer approach. These models are applied to the Chapman-Shaoxing dataset to classify atrial fibrillation, as well as another common arrhythmia, sinus bradycardia, and normal sinus rhythm heartbeats. The models enable the identification of the key regions of the heartbeat that determine the resulting classification, and highlight the importance of P-waves and T-waves, as well as heartbeat duration and signal amplitude, in distinguishing normal sinus rhythm from atrial fibrillation and sinus bradycardia.

Read more

4/30/2024

🔎

Total Score

0

A Personalized Zero-Shot ECG Arrhythmia Monitoring System: From Sparse Representation Based Domain Adaption to Energy Efficient Abnormal Beat Detection for Practical ECG Surveillance

Mehmet Yamac{c}, Mert Duman, .Ilke Adal{i}ou{g}lu, Serkan Kiranyaz, Moncef Gabbouj

This paper proposes a low-cost and highly accurate ECG-monitoring system intended for personalized early arrhythmia detection for wearable mobile sensors. Earlier supervised approaches for personalized ECG monitoring require both abnormal and normal heartbeats for the training of the dedicated classifier. However, in a real-world scenario where the personalized algorithm is embedded in a wearable device, such training data is not available for healthy people with no cardiac disorder history. In this study, (i) we propose a null space analysis on the healthy signal space obtained via sparse dictionary learning, and investigate how a simple null space projection or alternatively regularized least squares-based classification methods can reduce the computational complexity, without sacrificing the detection accuracy, when compared to sparse representation-based classification. (ii) Then we introduce a sparse representation-based domain adaptation technique in order to project other existing users' abnormal and normal signals onto the new user's signal space, enabling us to train the dedicated classifier without having any abnormal heartbeat of the new user. Therefore, zero-shot learning can be achieved without the need for synthetic abnormal heartbeat generation. An extensive set of experiments performed on the benchmark MIT-BIH ECG dataset shows that when this domain adaptation-based training data generator is used with a simple 1-D CNN classifier, the method outperforms the prior work by a significant margin. (iii) Then, by combining (i) and (ii), we propose an ensemble classifier that further improves the performance. This approach for zero-shot arrhythmia detection achieves an average accuracy level of 98.2% and an F1-Score of 92.8%. Finally, a personalized energy-efficient ECG monitoring scheme is proposed using the above-mentioned innovations.

Read more