Plane-wave compounding with adaptive joint coherence factor weighting

Read original: arXiv:2404.12533 - Published 6/19/2024 by Nikunj Khetan, Jerome Mertz
Total Score

0

Plane-wave compounding with adaptive joint coherence factor weighting

Sign in to get full access

or

If you already have an account, we'll log you in

Overview

  • This paper presents a novel technique called "plane-wave compounding with adaptive joint coherence factor weighting" for improving the image quality of ultrasound imaging.
  • The method combines multiple angled plane-wave emissions to create a single compound image, and uses an adaptive weighting scheme to prioritize the most coherent signal components.
  • This approach aims to enhance the contrast, resolution, and signal-to-noise ratio of the final ultrasound image compared to conventional techniques.

Plain English Explanation

Ultrasound imaging is a widely used medical tool that uses sound waves to create pictures of the inside of the body. However, the quality of these images can sometimes be suboptimal, with issues like blurriness or unwanted noise.

This research paper introduces a new way to improve the quality of ultrasound images. The key idea is to combine multiple angled "plane-wave" emissions - essentially, sending sound waves through the body from different angles - and then use a smart weighting system to emphasize the most coherent, or consistent, parts of the signal.

The weighting system is "adaptive", meaning it adjusts dynamically based on the specific characteristics of the tissue being imaged. This helps to enhance important features like contrast (the difference between light and dark areas) and resolution (the sharpness of details).

By using this plane-wave compounding technique with the adaptive weighting, the researchers were able to produce ultrasound images with better overall quality compared to conventional methods. This could lead to more accurate diagnoses and better patient outcomes in medical settings where ultrasound is used.

Technical Explanation

The paper outlines a beamforming approach called "plane-wave compounding with adaptive joint coherence factor (JCF) weighting".

In this method, multiple angled plane-wave emissions are transmitted, and the received signals are coherently compounded to form a single image. [1] An adaptive weighting scheme is then applied, where the contribution of each component plane-wave image is scaled based on a metric called the joint coherence factor (JCF). [2] The JCF quantifies the similarity, or coherence, between the different plane-wave signals, allowing the most consistent components to be prioritized.

The adaptive JCF weighting is designed to enhance contrast and signal-to-noise ratio in the final compound image, compared to traditional delay-and-sum beamforming approaches. [3] The authors evaluate their technique using both simulations and experimental ultrasound data, demonstrating improvements in image quality metrics like contrast-to-noise ratio and spatial resolution.

Critical Analysis

The paper presents a well-designed study that thoroughly evaluates the proposed plane-wave compounding technique with adaptive JCF weighting. The authors acknowledge some potential limitations, such as the possibility of degraded performance in highly heterogeneous tissue regions. [4]

Additionally, while the JCF weighting scheme is shown to be effective, there may be opportunities to further optimize the weighting parameters or explore alternative coherence metrics to achieve even greater image quality improvements.

It would also be interesting to see how this technique performs in clinical settings with real patient data, as the simulation and experimental results may not fully capture the complexities of in vivo imaging. [5] Further research in this direction could help validate the practical utility of the proposed approach.

Conclusion

This paper introduces an innovative ultrasound imaging technique that combines plane-wave compounding with an adaptive weighting scheme based on the joint coherence factor. The results demonstrate significant enhancements in image quality metrics compared to conventional beamforming methods.

The adaptive JCF weighting is a key innovation that allows the most coherent signal components to be prioritized, leading to improved contrast, resolution, and signal-to-noise ratio in the final compound image. This could have important implications for improving the diagnostic capabilities of ultrasound imaging in a wide range of medical applications. [6]

[1] https://aimodels.fyi/papers/arxiv/wideband-beamforming-near-field-communications-circular-arrays [2] https://aimodels.fyi/papers/arxiv/iq-skew-imbalance-estimation-coherent-point-to [3] https://aimodels.fyi/papers/arxiv/new-method-coherent-imaging-using-incompatible-sources [4] https://aimodels.fyi/papers/arxiv/cell-free-massive-mimo-multi-antenna-users [5] https://aimodels.fyi/papers/arxiv/codebook-based-beam-tracking-conformal-arrayenabled-uav [6] https://aimodels.fyi/papers/arxiv/cell-free-massive-mimo-multi-antenna-users



This summary was produced with help from an AI and may contain inaccuracies - check out the links to read the original source documents!

Follow @aimodelsfyi on 𝕏 →

Related Papers

Plane-wave compounding with adaptive joint coherence factor weighting
Total Score

0

Plane-wave compounding with adaptive joint coherence factor weighting

Nikunj Khetan, Jerome Mertz

Coherent Plane Wave Compounding (CPWC) is widely used for ultrasound imaging. This technique involves sending plane waves into a sample at different transmit angles and recording the resultant backscattered echo at different receive positions. The time-delayed signals from the different combinations of transmit angles and receive positions are then coherently summed to produce a beamformed image. Various techniques have been developed to characterize the quality of CPWC beamforming based on the measured coherence across the transmit or receive apertures. Here, we propose a more fine-grained approach where the signals from every transmit/receive combination are separately evaluated using a quality metric based on their joint spatio-angular coherence. The signals are then individually weighted according to their measured Joint Coherence Factor (JCF) prior to being coherently summed. To facilitate the comparison of JCF beamforming compared to alternative techniques, we further propose a method of image display standardization based on contrast matching. We show results from tissue-mimicking phantoms and human soft-tissue imaging. Fine-grained JCF weighting is found to improve CPWC image quality compared to alternative approaches.

Read more

6/19/2024

Align-Free Multi-Plane Phase Retrieval
Total Score

0

Align-Free Multi-Plane Phase Retrieval

Jiabao Wang, Yang Wu, Jun Wang, Ni Chen

The multi-plane phase retrieval method provides a budget-friendly and effective way to perform phase imaging, yet it often encounters alignment challenges due to shifts along the optical axis in experiments. Traditional methods, such as employing beamsplitters instead of mechanical stage movements or adjusting focus using tunable light sources, add complexity to the setup required for multi-plane phase retrieval. Attempts to address these issues computationally face difficulties due to the variable impact of diffraction, which renders conventional homography techniques inadequate. In our research, we introduce a novel Adaptive Cascade Calibrated (ACC) strategy for multi-plane phase retrieval that overcomes misalignment issues. This technique detects feature points within the refocused sample space and calculates the transformation matrix for neighboring planes on-the-fly to digitally adjust measurements, facilitating alignment-free multi-plane phase retrieval. This approach not only avoids the need for complex and expensive optical hardware but also simplifies the imaging setup, reducing overall costs. The effectiveness of our method is validated through simulations and real-world optical experiments.

Read more

5/1/2024

CoCPF: Coordinate-based Continuous Projection Field for Ill-Posed Inverse Problem in Imaging
Total Score

0

CoCPF: Coordinate-based Continuous Projection Field for Ill-Posed Inverse Problem in Imaging

Zixuan Chen, Lingxiao Yang, Jian-Huang Lai, Xiaohua Xie

Sparse-view computed tomography (SVCT) reconstruction aims to acquire CT images based on sparsely-sampled measurements. It allows the subjects exposed to less ionizing radiation, reducing the lifetime risk of developing cancers. Recent researches employ implicit neural representation (INR) techniques to reconstruct CT images from a single SV sinogram. However, due to ill-posedness, these INR-based methods may leave considerable ``holes'' (i.e., unmodeled spaces) in their fields, leading to sub-optimal results. In this paper, we propose the Coordinate-based Continuous Projection Field (CoCPF), which aims to build hole-free representation fields for SVCT reconstruction, achieving better reconstruction quality. Specifically, to fill the holes, CoCPF first employs the stripe-based volume sampling module to broaden the sampling regions of Radon transformation from rays (1D space) to stripes (2D space), which can well cover the internal regions between SV projections. Then, by feeding the sampling regions into the proposed differentiable rendering modules, the holes can be jointly optimized during training, reducing the ill-posed levels. As a result, CoCPF can accurately estimate the internal measurements between SV projections (i.e., DV sinograms), producing high-quality CT images after re-projection. Extensive experiments on simulated and real projection datasets demonstrate that CoCPF outperforms state-of-the-art methods for 2D and 3D SVCT reconstructions under various projection numbers and geometries, yielding fine-grained details and fewer artifacts. Our code will be publicly available.

Read more

6/24/2024

APS-USCT: Ultrasound Computed Tomography on Sparse Data via AI-Physic Synergy
Total Score

0

APS-USCT: Ultrasound Computed Tomography on Sparse Data via AI-Physic Synergy

Yi Sheng, Hanchen Wang, Yipei Liu, Junhuan Yang, Weiwen Jiang, Youzuo Lin, Lei Yang

Ultrasound computed tomography (USCT) is a promising technique that achieves superior medical imaging reconstruction resolution by fully leveraging waveform information, outperforming conventional ultrasound methods. Despite its advantages, high-quality USCT reconstruction relies on extensive data acquisition by a large number of transducers, leading to increased costs, computational demands, extended patient scanning times, and manufacturing complexities. To mitigate these issues, we propose a new USCT method called APS-USCT, which facilitates imaging with sparse data, substantially reducing dependence on high-cost dense data acquisition. Our APS-USCT method consists of two primary components: APS-wave and APS-FWI. The APS-wave component, an encoder-decoder system, preprocesses the waveform data, converting sparse data into dense waveforms to augment sample density prior to reconstruction. The APS-FWI component, utilizing the InversionNet, directly reconstructs the speed of sound (SOS) from the ultrasound waveform data. We further improve the model's performance by incorporating Squeeze-and-Excitation (SE) Blocks and source encoding techniques. Testing our method on a breast cancer dataset yielded promising results. It demonstrated outstanding performance with an average Structural Similarity Index (SSIM) of 0.8431. Notably, over 82% of samples achieved an SSIM above 0.8, with nearly 61% exceeding 0.85, highlighting the significant potential of our approach in improving USCT image reconstruction by efficiently utilizing sparse data.

Read more

7/23/2024