POLAFFINI: Efficient feature-based polyaffine initialization for improved non-linear image registration

Read original: arXiv:2407.03922 - Published 7/10/2024 by Antoine Legouhy, Ross Callaghan, Hojjat Azadbakht, Hui Zhang
Total Score

0

POLAFFINI: Efficient feature-based polyaffine initialization for improved non-linear image registration

Sign in to get full access

or

If you already have an account, we'll log you in

Overview

  • POLAFFINI is a method for improved non-linear image registration
  • It uses an efficient feature-based polyaffine initialization to improve the performance of non-linear registration
  • The approach aims to address challenges in existing non-linear registration methods

Plain English Explanation

POLAFFINI is a new technique for aligning and combining medical images, such as MRI scans, more accurately. Existing methods for non-linear image registration can be challenging and time-consuming. POLAFFINI tries to solve this by using a clever initialization step based on identifying key features in the images.

The key idea is to first find important landmarks or structures in the images, and then use those to estimate an initial 'polyaffine' transformation. This provides a good starting point for the subsequent non-linear registration process, making it more efficient and effective.

By leveraging these image features, POLAFFINI can overcome limitations of previous approaches and produce better alignments of medical scans. This could be useful for applications like analyzing changes over time or combining information from different imaging modalities.

Technical Explanation

The POLAFFINI method works by first identifying salient features in the images to be registered. It does this using a feature extraction technique. These features act as landmarks that can be used to estimate an initial polyaffine transformation between the images.

The polyaffine transformation is a type of non-linear mapping that allows for local deformations. By using this as an initialization, POLAFFINI can then refine the alignment through a subsequent non-linear registration step. This two-stage approach is more efficient and effective than trying to do the full non-linear registration from scratch.

The experiments in the paper demonstrate that POLAFFINI outperforms other initialization methods for non-linear registration, leading to better final alignments on a variety of medical imaging datasets.

Critical Analysis

The paper provides a thorough evaluation of POLAFFINI and compares it to alternative initialization approaches. However, it would be helpful to have more details on the specific feature extraction and polyaffine estimation components. Additionally, the authors note that POLAFFINI may be sensitive to the quality and quantity of the detected features, which could be a limitation in some cases.

Further research could explore ways to make the feature selection more robust, or investigate how POLAFFINI performs on a wider range of registration tasks and datasets. It would also be interesting to see comparisons to deep learning-based registration methods, which have shown promising results in recent years.

Conclusion

POLAFFINI presents an efficient feature-based approach for initializing non-linear image registration. By leveraging salient image structures, it can provide a good starting point for the subsequent deformable registration step. This leads to improved alignment accuracy compared to other initialization methods. While the technique shows promise, further work is needed to fully understand its strengths, limitations, and potential applications in medical imaging and beyond.



This summary was produced with help from an AI and may contain inaccuracies - check out the links to read the original source documents!

Follow @aimodelsfyi on 𝕏 →

Related Papers

POLAFFINI: Efficient feature-based polyaffine initialization for improved non-linear image registration
Total Score

0

POLAFFINI: Efficient feature-based polyaffine initialization for improved non-linear image registration

Antoine Legouhy, Ross Callaghan, Hojjat Azadbakht, Hui Zhang

This paper presents an efficient feature-based approach to initialize non-linear image registration. Today, nonlinear image registration is dominated by methods relying on intensity-based similarity measures. A good estimate of the initial transformation is essential, both for traditional iterative algorithms and for recent one-shot deep learning (DL)-based alternatives. The established approach to estimate this starting point is to perform affine registration, but this may be insufficient due to its parsimonious, global, and non-bending nature. We propose an improved initialization method that takes advantage of recent advances in DL-based segmentation techniques able to instantly estimate fine-grained regional delineations with state-of-the-art accuracies. Those segmentations are used to produce local, anatomically grounded, feature-based affine matchings using iteration-free closed-form expressions. Estimated local affine transformations are then fused, with the log-Euclidean polyaffine framework, into an overall dense diffeomorphic transformation. We show that, compared to its affine counterpart, the proposed initialization leads to significantly better alignment for both traditional and DL-based non-linear registration algorithms. The proposed approach is also more robust and significantly faster than commonly used affine registration algorithms such as FSL FLIRT.

Read more

7/10/2024

Deep Implicit Optimization for Robust and Flexible Image Registration
Total Score

0

Deep Implicit Optimization for Robust and Flexible Image Registration

Rohit Jena, Pratik Chaudhari, James C. Gee

Deep Learning in Image Registration (DLIR) methods have been tremendously successful in image registration due to their speed and ability to incorporate weak label supervision at training time. However, DLIR methods forego many of the benefits of classical optimization-based methods. The functional nature of deep networks do not guarantee that the predicted transformation is a local minima of the registration objective, the representation of the transformation (displacement/velocity field/affine) is fixed, and the networks are not robust to domain shift. Our method aims to bridge this gap between classical and learning methods by incorporating optimization as a layer in a deep network. A deep network is trained to predict multi-scale dense feature images that are registered using a black box iterative optimization solver. This optimal warp is then used to minimize image and label alignment errors. By implicitly differentiating end-to-end through an iterative optimization solver, our learned features are registration and label-aware, and the warp functions are guaranteed to be local minima of the registration objective in the feature space. Our framework shows excellent performance on in-domain datasets, and is agnostic to domain shift such as anisotropy and varying intensity profiles. For the first time, our method allows switching between arbitrary transformation representations (free-form to diffeomorphic) at test time with zero retraining. End-to-end feature learning also facilitates interpretability of features, and out-of-the-box promptability using additional label-fidelity terms at inference.

Read more

6/12/2024

🏋️

Total Score

0

Anatomy-aware and acquisition-agnostic joint registration with SynthMorph

Malte Hoffmann, Andrew Hoopes, Douglas N. Greve, Bruce Fischl, Adrian V. Dalca

Affine image registration is a cornerstone of medical image analysis. While classical algorithms can achieve excellent accuracy, they solve a time-consuming optimization for every image pair. Deep-learning (DL) methods learn a function that maps an image pair to an output transform. Evaluating the function is fast, but capturing large transforms can be challenging, and networks tend to struggle if a test-image characteristic shifts from the training domain, such as resolution. Most affine methods are agnostic to the anatomy the user wishes to align, meaning the registration will be inaccurate if algorithms consider all structures in the image. We address these shortcomings with SynthMorph, a fast, symmetric, diffeomorphic, and easy-to-use DL tool for joint affine-deformable registration of any brain image without preprocessing. First, we leverage a strategy that trains networks with widely varying images synthesized from label maps, yielding robust performance for image types unseen at training. Second, we optimize the spatial overlap of select anatomical labels. This enables networks to distinguish anatomy of interest from irrelevant structures, removing the need for preprocessing that excludes content that may impinge on anatomy-specific registration. Third, we combine the affine model with a deformable hypernetwork that lets users choose the optimal deformation-field regularity for their specific data, at registration time, in a fraction of the time required by classical methods. We analyze how competing architectures learn affine transforms and compare state-of-the-art registration tools across an extremely diverse set of neuroimaging data, aiming to truly capture the behavior of methods in the real world. SynthMorph demonstrates high accuracy and is available at https://w3id.org/synthmorph, as a single complete end-to-end solution for registration of brain MRI.

Read more

7/15/2024

Impact of Initialization on Intra-subject Pediatric Brain MR Image Registration: A Comparative Analysis between SyN ANTs and Deep Learning-Based Approaches
Total Score

0

Impact of Initialization on Intra-subject Pediatric Brain MR Image Registration: A Comparative Analysis between SyN ANTs and Deep Learning-Based Approaches

Andjela Dimitrijevic, Vincent Noblet, Benjamin De Leener

This study evaluates the performance of conventional SyN ANTs and learning-based registration methods in the context of pediatric neuroimaging, specifically focusing on intrasubject deformable registration. The comparison involves three approaches: without (NR), with rigid (RR), and with rigid and affine (RAR) initializations. In addition to initialization, performances are evaluated in terms of accuracy, speed, and the impact of age intervals and sex per pair. Data consists of the publicly available MRI scans from the Calgary Preschool dataset, which includes 63 children aged 2-7 years, allowing for 431 registration pairs. We implemented the unsupervised DL framework with a U-Net architecture using DeepReg and it was 5-fold cross-validated. Evaluation includes Dice scores for tissue segmentation from 18 smaller regions obtained by SynthSeg, analysis of log Jacobian determinants, and registration pro-rated training and inference times. Learning-based approaches, with or without linear initializations, exhibit slight superiority over SyN ANTs in terms of Dice scores. Indeed, DL-based implementations with RR and RAR initializations significantly outperform SyN ANTs. Both SyN ANTs and DL-based registration involve parameter optimization, but the choice between these methods depends on the scale of registration: network-based for broader coverage or SyN ANTs for specific structures. Both methods face challenges with larger age intervals due to greater growth changes. The main takeaway is that while DL-based methods show promise with faster and more accurate registrations, SyN ANTs remains robust and generalizable without the need for extensive training, highlighting the importance of method selection based on specific registration needs in the pediatric context. Our code is available at https://github.com/neuropoly/pediatric-DL-registration

Read more

7/1/2024