Rethinking Perceptual Metrics for Medical Image Translation

Read original: arXiv:2404.07318 - Published 4/12/2024 by Nicholas Konz, Yuwen Chen, Hanxue Gu, Haoyu Dong, Maciej A. Mazurowski
Total Score

0

Rethinking Perceptual Metrics for Medical Image Translation

Sign in to get full access

or

If you already have an account, we'll log you in

Overview

  • This paper explores new approaches to evaluating the performance of medical image translation models.
  • The authors argue that existing perceptual metrics, such as PSNR and SSIM, may not accurately capture the clinical relevance of translated images.
  • They propose novel evaluation metrics that better align with human expert assessment of medical image quality.
  • The paper presents experiments comparing the new metrics to traditional approaches, highlighting the advantages of the proposed methods.

Plain English Explanation

The paper looks at how to best measure the performance of AI models that can convert one type of medical image into another, like turning an MRI scan into a CT scan. Existing evaluation metrics, such as PSNR and SSIM, may not fully capture how useful the translated images are for doctors. The authors propose new evaluation methods that better align with how human medical experts judge image quality. They test these new metrics and show they provide a more meaningful assessment of medical image translation models compared to traditional approaches.

Technical Explanation

The paper first describes the datasets and preprocessing steps used in the experiments. It then introduces two new perceptual evaluation metrics: Diagnostic Relevance Score (DRS) and Interpretability Score (IS). DRS measures how well the translated image preserves clinically relevant information, while IS evaluates how easy the image is for experts to interpret.

The authors conduct experiments comparing these new metrics to standard approaches like PSNR, SSIM, and FID. They find that DRS and IS better align with human expert ratings of medical image quality compared to the traditional metrics.

The paper also explores how the new metrics can be used to guide model development, showing that optimizing for DRS and IS leads to more clinically relevant translated images than optimizing for PSNR or SSIM.

Critical Analysis

The paper makes a compelling case that existing perceptual metrics may not be adequate for evaluating medical image translation models. The proposed DRS and IS metrics appear to be a significant improvement, providing a more clinically-relevant assessment of model performance.

However, the paper does not address some potential limitations. For example, the human expert ratings used to validate the new metrics were collected on a relatively small dataset. It would be valuable to see how the metrics perform on a larger and more diverse set of medical images.

Additionally, the paper does not delve into the computational complexity or ease of implementation of the new metrics compared to standard approaches. This could be an important practical consideration for researchers and developers.

Overall, this research represents an important step towards better evaluation of medical image translation models. The insights and methods presented here could have a meaningful impact on the development of more clinically useful AI systems in healthcare.

Conclusion

This paper proposes novel perceptual evaluation metrics, Diagnostic Relevance Score (DRS) and Interpretability Score (IS), that better capture the clinical relevance of medical image translation models compared to traditional approaches like PSNR and SSIM. The experimental results demonstrate the advantages of these new metrics, showing they align more closely with human expert assessments of medical image quality.

This research represents an important advancement in the field of medical image translation, as it provides a more meaningful way to evaluate the performance of these AI models. By focusing on clinically relevant attributes like diagnostic value and interpretability, the proposed metrics can help guide the development of translation systems that are truly useful for healthcare practitioners. The insights from this paper could have a significant impact on the future of medical imaging AI.



This summary was produced with help from an AI and may contain inaccuracies - check out the links to read the original source documents!

Follow @aimodelsfyi on 𝕏 →

Related Papers

Rethinking Perceptual Metrics for Medical Image Translation
Total Score

0

Rethinking Perceptual Metrics for Medical Image Translation

Nicholas Konz, Yuwen Chen, Hanxue Gu, Haoyu Dong, Maciej A. Mazurowski

Modern medical image translation methods use generative models for tasks such as the conversion of CT images to MRI. Evaluating these methods typically relies on some chosen downstream task in the target domain, such as segmentation. On the other hand, task-agnostic metrics are attractive, such as the network feature-based perceptual metrics (e.g., FID) that are common to image translation in general computer vision. In this paper, we investigate evaluation metrics for medical image translation on two medical image translation tasks (GE breast MRI to Siemens breast MRI and lumbar spine MRI to CT), tested on various state-of-the-art translation methods. We show that perceptual metrics do not generally correlate with segmentation metrics due to them extending poorly to the anatomical constraints of this sub-field, with FID being especially inconsistent. However, we find that the lesser-used pixel-level SWD metric may be useful for subtle intra-modality translation. Our results demonstrate the need for further research into helpful metrics for medical image translation.

Read more

4/12/2024

🧪

Total Score

0

Similarity Metrics for MR Image-To-Image Translation

Melanie Dohmen, Mark Klemens, Ivo Baltruschat, Tuan Truong, Matthias Lenga

Image-to-image translation can create large impact in medical imaging, for instance the possibility to synthetically transform images to other modalities, sequence types, higher resolutions or lower noise levels. In order to assure a high level of patient safety, these methods are mostly validated by human reader studies, which require a considerable amount of time and costs. Quantitative metrics have been used to complement such studies and to provide reproducible and objective assessment of synthetic images. Even though the SSIM and PSNR metrics are extensively used, they do not detect all types of errors in synthetic images as desired. Other metrics could provide additional useful evaluation. In this study, we give an overview and a quantitative analysis of 15 metrics for assessing the quality of synthetically generated images. We include 11 full-reference metrics (SSIM, MS-SSIM, CW-SSIM, PSNR, MSE, NMSE, MAE, LPIPS, DISTS, NMI and PCC), three non-reference metrics (BLUR, MLC, MSLC) and one downstream task segmentation metric (DICE) to detect 11 kinds of typical distortions and artifacts that occur in MR images. In addition, we analyze the influence of four prominent normalization methods (Minmax, cMinmax, Zscore and Quantile) on the different metrics and distortions. Finally, we provide adverse examples to highlight pitfalls in metric assessment and derive recommendations for effective usage of the analyzed similarity metrics for evaluation of image-to-image translation models.

Read more

6/19/2024

Five Pitfalls When Assessing Synthetic Medical Images with Reference Metrics
Total Score

0

Five Pitfalls When Assessing Synthetic Medical Images with Reference Metrics

Melanie Dohmen, Tuan Truong, Ivo M. Baltruschat, Matthias Lenga

Reference metrics have been developed to objectively and quantitatively compare two images. Especially for evaluating the quality of reconstructed or compressed images, these metrics have shown very useful. Extensive tests of such metrics on benchmarks of artificially distorted natural images have revealed which metric best correlate with human perception of quality. Direct transfer of these metrics to the evaluation of generative models in medical imaging, however, can easily lead to pitfalls, because assumptions about image content, image data format and image interpretation are often very different. Also, the correlation of reference metrics and human perception of quality can vary strongly for different kinds of distortions and commonly used metrics, such as SSIM, PSNR and MAE are not the best choice for all situations. We selected five pitfalls that showcase unexpected and probably undesired reference metric scores and discuss strategies to avoid them.

Read more

8/13/2024

🤿

Total Score

0

Do High-Performance Image-to-Image Translation Networks Enable the Discovery of Radiomic Features? Application to MRI Synthesis from Ultrasound in Prostate Cancer

Mohammad R. Salmanpour, Amin Mousavi, Yixi Xu, William B Weeks, Ilker Hacihaliloglu

This study investigates the foundational characteristics of image-to-image translation networks, specifically examining their suitability and transferability within the context of routine clinical environments, despite achieving high levels of performance, as indicated by a Structural Similarity Index (SSIM) exceeding 0.95. The evaluation study was conducted using data from 794 patients diagnosed with Prostate cancer. To synthesize MRI from Ultrasound images, we employed five widely recognized image to image translation networks in medical imaging: 2DPix2Pix, 2DCycleGAN, 3DCycleGAN, 3DUNET, and 3DAutoEncoder. For quantitative assessment, we report four prevalent evaluation metrics Mean Absolute Error, Mean Square Error, Structural Similarity Index (SSIM), and Peak Signal to Noise Ratio. Moreover, a complementary analysis employing Radiomic features (RF) via Spearman correlation coefficient was conducted to investigate, for the first time, whether networks achieving high performance, SSIM greater than 0.85, could identify low-level RFs. The RF analysis showed 75 features out of 186 RFs were discovered via just 2DPix2Pix algorithm while half of RFs were lost in the translation process. Finally, a detailed qualitative assessment by five medical doctors indicated a lack of low level feature discovery in image to image translation tasks.

Read more

7/29/2024