RSF-Conv: Rotation-and-Scale Equivariant Fourier Parameterized Convolution for Retinal Vessel Segmentation

Read original: arXiv:2309.15638 - Published 9/9/2024 by Zihong Sun, Hong Wang, Qi Xie, Yefeng Zheng, Deyu Meng
Total Score

0

🏅

Sign in to get full access

or

If you already have an account, we'll log you in

Overview

  • Retinal vessel segmentation is crucial for diagnosing eye diseases, but it's a challenging task due to the complex vascular structure
  • Convolutional neural networks (CNNs) have achieved great success in retinal vessel segmentation by capturing the translation symmetry in the vessels
  • However, the rotation-and-scale symmetry, which is a more widespread property in retinal vessels, is not well characterized by CNNs
  • The researchers propose a rotation-and-scale equivariant Fourier parameterized convolution (RSF-Conv) to address this issue and improve retinal vessel segmentation

Plain English Explanation

The blood vessels in the back of the eye, called the retina, can provide important information about a person's eye health and overall health. Accurately detecting and mapping these retinal blood vessels is crucial for diagnosing various eye-related diseases. However, this is a difficult task because the retinal blood vessels have a very intricate and complex structure.

Recent advances in convolutional neural networks have helped improve retinal vessel segmentation by capturing the way the vessels are arranged and oriented in a predictable, or "translation symmetric," pattern. But there's another important property of retinal vessels - their ability to appear at different sizes and rotations - that current methods don't handle as well.

To address this, the researchers developed a new type of convolutional layer called rotation-and-scale equivariant Fourier parameterized convolution (RSF-Conv). This allows their neural network models to better recognize retinal vessels at different scales and orientations. They show that integrating RSF-Conv into existing segmentation models like U-Net and Iter-Net leads to improved performance, especially when testing on data from different sources (known as "out-of-domain" evaluation).

The ability to generalize well to diverse datasets is crucial for making retinal vessel segmentation techniques truly useful in real-world clinical settings, where healthcare providers may need to analyze images from different imaging devices or hospital systems. The researchers also demonstrate that their RSF-Conv approach can be beneficial for other retinal analysis tasks like artery/vein classification, suggesting its broader applicability in ophthalmology.

Technical Explanation

The researchers propose a rotation-and-scale equivariant Fourier parameterized convolution (RSF-Conv) module to better capture the rotation-and-scale symmetry inherent in retinal vessel structures. They provide a detailed equivariance analysis to show how RSF-Conv can be integrated into existing convolutional neural network (CNN) architectures in a plug-and-play manner.

Specifically, the RSF-Conv layer replaces the standard convolution filters in two popular segmentation models - U-Net and Iter-Net. The resulting RSF-Conv+U-Net and RSF-Conv+Iter-Net models not only show slight performance advantages on in-domain evaluation, but more importantly, significantly outperform all comparison methods on out-of-domain evaluation. This indicates the remarkable generalization capability of the RSF-Conv module, which is crucial for addressing the prevalent cross-device and cross-hospital challenges in real-world clinical practice.

To further demonstrate the effectiveness of RSF-Conv, the researchers also apply their models to the task of retinal artery/vein classification, achieving promising results and suggesting the broader applicability of their approach in ophthalmological analysis.

Critical Analysis

The researchers have provided a well-designed study that addresses an important limitation of existing CNN-based retinal vessel segmentation methods - their inability to effectively capture the rotation-and-scale symmetry inherent in retinal vessel structures.

One potential caveat is that the proposed RSF-Conv module, while a general component that can be integrated into various network architectures, may still require careful hyperparameter tuning and architectural design choices to fully unleash its potential. The researchers mention this to some extent, noting that the performance gains from RSF-Conv are more significant when combined with the Iter-Net architecture compared to U-Net.

Additionally, while the researchers demonstrate the generalization capabilities of their models through out-of-domain evaluation, it would be valuable to further investigate the performance and robustness of RSF-Conv+U-Net and RSF-Conv+Iter-Net on even more diverse datasets, imaging modalities, and clinical settings to fully assess their practical utility.

Finally, the researchers could consider exploring the integration of RSF-Conv with other state-of-the-art segmentation architectures beyond U-Net and Iter-Net, as well as investigating potential synergies with other equivariance-based approaches, such as steerable convolutions, to further push the boundaries of retinal vessel segmentation performance.

Conclusion

The proposed rotation-and-scale equivariant Fourier parameterized convolution (RSF-Conv) represents a meaningful advance in retinal vessel segmentation by effectively capturing the rotation-and-scale symmetry inherent in retinal vessel structures. The researchers have demonstrated the integration of RSF-Conv into existing segmentation models like U-Net and Iter-Net, leading to improved performance, especially on out-of-domain evaluation.

This is a crucial step towards developing more robust and generalizable retinal vessel segmentation techniques that can be reliably deployed in real-world clinical settings, where healthcare providers may need to analyze images from diverse sources. The researchers have also shown the broader applicability of their RSF-Conv approach in other retinal analysis tasks, suggesting its potential for wider adoption in ophthalmological computer vision.



This summary was produced with help from an AI and may contain inaccuracies - check out the links to read the original source documents!

Follow @aimodelsfyi on 𝕏 →

Related Papers

🏅

Total Score

0

RSF-Conv: Rotation-and-Scale Equivariant Fourier Parameterized Convolution for Retinal Vessel Segmentation

Zihong Sun, Hong Wang, Qi Xie, Yefeng Zheng, Deyu Meng

Retinal vessel segmentation is of great clinical significance for the diagnosis of many eye-related diseases, but it is still a formidable challenge due to the intricate vascular morphology. With the skillful characterization of the translation symmetry existing in retinal vessels, convolutional neural networks (CNNs) have achieved great success in retinal vessel segmentation. However, the rotation-and-scale symmetry, as a more widespread image prior in retinal vessels, fails to be characterized by CNNs. Therefore, we propose a rotation-and-scale equivariant Fourier parameterized convolution (RSF-Conv) specifically for retinal vessel segmentation, and provide the corresponding equivariance analysis. As a general module, RSF-Conv can be integrated into existing networks in a plug-and-play manner while significantly reducing the number of parameters. For instance, we replace the traditional convolution filters in U-Net and Iter-Net with RSF-Convs, and faithfully conduct comprehensive experiments. RSF-Conv+U-Net and RSF-Conv+Iter-Net not only have slight advantages under in-domain evaluation, but more importantly, outperform all comparison methods by a significant margin under out-of-domain evaluation. It indicates the remarkable generalization of RSF-Conv, which holds greater practical clinical significance for the prevalent cross-device and cross-hospital challenges in clinical practice. To comprehensively demonstrate the effectiveness of RSF-Conv, we also apply RSF-Conv+U-Net and RSF-Conv+Iter-Net to retinal artery/vein classification and achieve promising performance as well, indicating its clinical application potential.

Read more

9/9/2024

🧪

Total Score

0

GPU-Accelerated RSF Level Set Evolution for Large-Scale Microvascular Segmentation

Meher Niger, Helya Goharbavang, Taeyong Ahn, Emily K. Alley, Joshua D. Wythe, Guoning Chen, David Mayerich

Microvascular networks are challenging to model because these structures are currently near the diffraction limit for most advanced three-dimensional imaging modalities, including confocal and light sheet microscopy. This makes semantic segmentation difficult, because individual components of these networks fluctuate within the confines of individual pixels. Level set methods are ideally suited to solve this problem by providing surface and topological constraints on the resulting model, however these active contour techniques are extremely time intensive and impractical for terabyte-scale images. We propose a reformulation and implementation of the region-scalable fitting (RSF) level set model that makes it amenable to three-dimensional evaluation using both single-instruction multiple data (SIMD) and single-program multiple-data (SPMD) parallel processing. This enables evaluation of the level set equation on independent regions of the data set using graphics processing units (GPUs), making large-scale segmentation of high-resolution networks practical and inexpensive. We tested this 3D parallel RSF approach on multiple data sets acquired using state-of-the-art imaging techniques to acquire microvascular data, including micro-CT, light sheet fluorescence microscopy (LSFM) and milling microscopy. To assess the performance and accuracy of the RSF model, we conducted a Monte-Carlo-based validation technique to compare results to other segmentation methods. We also provide a rigorous profiling to show the gains in processing speed leveraging parallel hardware. This study showcases the practical application of the RSF model, emphasizing its utility in the challenging domain of segmenting large-scale high-topology network structures with a particular focus on building microvascular models.

Read more

4/4/2024

📊

Total Score

0

Leveraging SO(3)-steerable convolutions for pose-robust semantic segmentation in 3D medical data

Ivan Diaz, Mario Geiger, Richard Iain McKinley

Convolutional neural networks (CNNs) allow for parameter sharing and translational equivariance by using convolutional kernels in their linear layers. By restricting these kernels to be SO(3)-steerable, CNNs can further improve parameter sharing. These rotationally-equivariant convolutional layers have several advantages over standard convolutional layers, including increased robustness to unseen poses, smaller network size, and improved sample efficiency. Despite this, most segmentation networks used in medical image analysis continue to rely on standard convolutional kernels. In this paper, we present a new family of segmentation networks that use equivariant voxel convolutions based on spherical harmonics. These networks are robust to data poses not seen during training, and do not require rotation-based data augmentation during training. In addition, we demonstrate improved segmentation performance in MRI brain tumor and healthy brain structure segmentation tasks, with enhanced robustness to reduced amounts of training data and improved parameter efficiency. Code to reproduce our results, and to implement the equivariant segmentation networks for other tasks is available at http://github.com/SCAN-NRAD/e3nn_Unet

Read more

5/20/2024

SRE-CNN: A Spatiotemporal Rotation-Equivariant CNN for Cardiac Cine MR Imaging
Total Score

0

SRE-CNN: A Spatiotemporal Rotation-Equivariant CNN for Cardiac Cine MR Imaging

Yuliang Zhu, Jing Cheng, Zhuo-Xu Cui, Jianfeng Ren, Chengbo Wang, Dong Liang

Dynamic MR images possess various transformation symmetries,including the rotation symmetry of local features within the image and along the temporal dimension. Utilizing these symmetries as prior knowledge can facilitate dynamic MR imaging with high spatiotemporal resolution. Equivariant CNN is an effective tool to leverage the symmetry priors. However, current equivariant CNN methods fail to fully exploit these symmetry priors in dynamic MR imaging. In this work, we propose a novel framework of Spatiotemporal Rotation-Equivariant CNN (SRE-CNN), spanning from the underlying high-precision filter design to the construction of the temporal-equivariant convolutional module and imaging model, to fully harness the rotation symmetries inherent in dynamic MR images. The temporal-equivariant convolutional module enables exploitation the rotation symmetries in both spatial and temporal dimensions, while the high-precision convolutional filter, based on parametrization strategy, enhances the utilization of rotation symmetry of local features to improve the reconstruction of detailed anatomical structures. Experiments conducted on highly undersampled dynamic cardiac cine data (up to 20X) have demonstrated the superior performance of our proposed approach, both quantitatively and qualitatively.

Read more

9/16/2024