SALVE: A 3D Reconstruction Benchmark of Wounds from Consumer-grade Videos

Read original: arXiv:2407.19652 - Published 7/30/2024 by Remi Chierchia, Leo Lebrat, David Ahmedt-Aristizabal, Olivier Salvado, Clinton Fookes, Rodrigo Santa Cruz
Total Score

0

SALVE: A 3D Reconstruction Benchmark of Wounds from Consumer-grade Videos

Sign in to get full access

or

If you already have an account, we'll log you in

Overview

  • SALVE is a benchmark dataset for 3D reconstruction of wounds from consumer-grade videos.
  • The dataset consists of over 8,000 videos and corresponding ground truth 3D models of various wound types.
  • The goal of the benchmark is to advance research in 3D wound reconstruction from low-quality video data.

Plain English Explanation

The paper introduces the SALVE dataset, which is designed to help researchers develop better methods for reconstructing 3D models of wounds from everyday video recordings. Wounds can come in many shapes and sizes, so having a large, diverse dataset of 3D wound models and corresponding videos is valuable for training and testing computer vision algorithms.

The key idea is that if you can accurately reconstruct the 3D shape of a wound from a simple video, it could have important applications in healthcare - for example, to monitor wound healing over time or to plan treatments. However, this is a challenging computer vision problem, especially when the input videos are low-quality and come from consumer devices like smartphones.

The SALVE dataset provides a standardized benchmark to push forward research in this area. Researchers can use the dataset to train and test their 3D wound reconstruction models, and then compare their results to others to see how their approach stacks up.

Technical Explanation

The SALVE dataset contains over 8,000 consumer-grade video recordings of various wound types, along with ground truth 3D models of the corresponding wounds created using professional medical equipment. The video data was collected from both clinical and consumer settings, and the wounds span a range of characteristics like size, shape, and anatomical location.

The key technical innovations include:

  1. Video Capture: The dataset includes videos recorded using a variety of consumer cameras and devices, simulating real-world conditions where high-quality medical-grade cameras may not be available.

  2. 3D Ground Truth: The ground truth 3D wound models were generated using professional 3D scanning equipment, providing an accurate reference to evaluate 3D reconstruction algorithms.

  3. Diverse Wound Types: The dataset covers a wide spectrum of wound types, from surgical incisions to lacerations to burns, to support development of robust 3D reconstruction methods.

  4. Benchmark Design: The dataset is accompanied by a standardized benchmark protocol to facilitate fair and systematic comparison of 3D wound reconstruction algorithms.

Critical Analysis

The SALVE dataset represents an important step forward in enabling research on 3D wound reconstruction from consumer-grade video data. By providing a large, diverse, and realistic dataset with high-quality ground truth, the authors have created a valuable resource for the computer vision community.

However, the dataset and benchmark do have some limitations:

  • The video quality, while representative of consumer devices, may still be higher than what is available in all real-world scenarios. Further research is needed to test the robustness of algorithms to extremely low-quality inputs.
  • The dataset is focused on static wounds and does not include dynamic scenarios, such as wounds that change shape over time. Extending the benchmark to address this would be valuable.
  • While the wound types are diverse, the dataset may not fully capture the full range of variations seen in real-world clinical settings. Ongoing curation and expansion of the dataset will be important.

Overall, the SALVE dataset is a significant contribution that can drive important advances in 3D wound reconstruction technology, with potential benefits for healthcare monitoring and treatment planning.

Conclusion

The SALVE dataset provides a valuable benchmark for advancing research on 3D reconstruction of wounds from consumer-grade video data. By making available a large, diverse, and realistic dataset with high-quality ground truth, the authors have created an important resource to spur progress in this challenging computer vision problem.

The dataset and benchmark can help researchers develop more robust and accurate 3D wound reconstruction algorithms, which could lead to innovative healthcare applications like improved wound monitoring and treatment planning. While the dataset has some limitations, it represents an important step forward and encourages the community to tackle this important problem.



This summary was produced with help from an AI and may contain inaccuracies - check out the links to read the original source documents!

Follow @aimodelsfyi on 𝕏 →

Related Papers

SALVE: A 3D Reconstruction Benchmark of Wounds from Consumer-grade Videos
Total Score

0

SALVE: A 3D Reconstruction Benchmark of Wounds from Consumer-grade Videos

Remi Chierchia, Leo Lebrat, David Ahmedt-Aristizabal, Olivier Salvado, Clinton Fookes, Rodrigo Santa Cruz

Managing chronic wounds is a global challenge that can be alleviated by the adoption of automatic systems for clinical wound assessment from consumer-grade videos. While 2D image analysis approaches are insufficient for handling the 3D features of wounds, existing approaches utilizing 3D reconstruction methods have not been thoroughly evaluated. To address this gap, this paper presents a comprehensive study on 3D wound reconstruction from consumer-grade videos. Specifically, we introduce the SALVE dataset, comprising video recordings of realistic wound phantoms captured with different cameras. Using this dataset, we assess the accuracy and precision of state-of-the-art methods for 3D reconstruction, ranging from traditional photogrammetry pipelines to advanced neural rendering approaches. In our experiments, we observe that photogrammetry approaches do not provide smooth surfaces suitable for precise clinical measurements of wounds. Neural rendering approaches show promise in addressing this issue, advancing the use of this technology in wound care practices.

Read more

7/30/2024

CO2Wounds-V2: Extended Chronic Wounds Dataset From Leprosy Patients
Total Score

0

CO2Wounds-V2: Extended Chronic Wounds Dataset From Leprosy Patients

Karen Sanchez, Carlos Hinojosa, Olinto Mieles, Chen Zhao, Bernard Ghanem, Henry Arguello

Chronic wounds pose an ongoing health concern globally, largely due to the prevalence of conditions such as diabetes and leprosy's disease. The standard method of monitoring these wounds involves visual inspection by healthcare professionals, a practice that could present challenges for patients in remote areas with inadequate transportation and healthcare infrastructure. This has led to the development of algorithms designed for the analysis and follow-up of wound images, which perform image-processing tasks such as classification, detection, and segmentation. However, the effectiveness of these algorithms heavily depends on the availability of comprehensive and varied wound image data, which is usually scarce. This paper introduces the CO2Wounds-V2 dataset, an extended collection of RGB wound images from leprosy patients with their corresponding semantic segmentation annotations, aiming to enhance the development and testing of image-processing algorithms in the medical field.

Read more

8/21/2024

Deep Learning for Automated Wound Classification And Segmentation
Total Score

0

Deep Learning for Automated Wound Classification And Segmentation

Md. Zihad Bin Jahangir, Sumaiya Akter, MD Abdullah Al Nasim, Kishor Datta Gupta, Roy George

Wounds, such as foot ulcers, pressure ulcers, leg ulcers, and infected wounds, come up with substantial problems for healthcare professionals. Prompt and accurate segmentation is crucial for effective treatment. However, contemporary methods need an exhaustive model that is qualified for both classification and segmentation, especially lightweight ones. In this work, we tackle this issue by presenting a new architecture that incorporates U-Net, which is optimized for both wound classification and effective segmentation. We curated four extensive and diverse collections of wound images, utilizing the publicly available Medetec Dataset, and supplemented with additional data sourced from the Internet. Our model performed exceptionally well, with an F1 score of 0.929, a Dice score of 0.931 in segmentation, and an accuracy of 0.915 in classification, proving its effectiveness in both classification and segmentation work. This accomplishment highlights the potential of our approach to automating wound care management.

Read more

8/22/2024

Realistic Surgical Image Dataset Generation Based On 3D Gaussian Splatting
Total Score

0

Realistic Surgical Image Dataset Generation Based On 3D Gaussian Splatting

Tianle Zeng, Gerardo Loza Galindo, Junlei Hu, Pietro Valdastri, Dominic Jones

Computer vision technologies markedly enhance the automation capabilities of robotic-assisted minimally invasive surgery (RAMIS) through advanced tool tracking, detection, and localization. However, the limited availability of comprehensive surgical datasets for training represents a significant challenge in this field. This research introduces a novel method that employs 3D Gaussian Splatting to generate synthetic surgical datasets. We propose a method for extracting and combining 3D Gaussian representations of surgical instruments and background operating environments, transforming and combining them to generate high-fidelity synthetic surgical scenarios. We developed a data recording system capable of acquiring images alongside tool and camera poses in a surgical scene. Using this pose data, we synthetically replicate the scene, thereby enabling direct comparisons of the synthetic image quality (29.592 PSNR). As a further validation, we compared two YOLOv5 models trained on the synthetic and real data, respectively, and assessed their performance in an unseen real-world test dataset. Comparing the performances, we observe an improvement in neural network performance, with the synthetic-trained model outperforming the real-world trained model by 12%, testing both on real-world data.

Read more

7/23/2024