Overview

  • The paper proposes a calibration system to integrate augmented reality (AR) head-mounted displays (HMDs) with computer-assisted orthopaedic surgery (CAOS) systems.
  • The calibration method uses infrared-reflective marker-arrays commonly used in CAOS to detect the pose of the HMD and register it with the CAOS system.
  • The approach aims to allow surgeons to maintain focus on the operating site rather than external displays during surgery, improving immersion and efficiency.

Plain English Explanation

The paper describes a way to seamlessly integrate augmented reality (AR) headsets with the computer systems used in orthopaedic surgery.

In traditional surgery, doctors often need to look away from the patient to check information on external screens and displays. The researchers wanted to find a way for doctors to keep their eyes on the patient the entire time, using AR technology to project helpful information directly into their field of view.

To do this, they developed a calibration process that allows the AR headset to accurately detect the positions of special reflective markers placed around the surgical area. By recognizing these markers, the headset can figure out exactly where it is in relation to the patient and the surgical plan, and display relevant information as a hologram that the doctor can see without looking away.

The key innovation is using the same marker system that the surgical computer already relies on, rather than requiring additional sensors or setup. This makes the integration quick and easy, without disrupting the surgeon's normal workflow.

Technical Explanation

The researchers propose a calibration system that allows augmented reality (AR) head-mounted displays (HMDs) to be accurately registered with computer-assisted orthopaedic surgery (CAOS) systems.

The calibration leverages the infrared-reflective marker-arrays that are widely used in CAOS to track the positions of surgical tools and the patient. The HMD, in this case a Microsoft HoloLens 2, can detect the pose of these marker-arrays using its own onboard infrared sensors and time-of-flight depth cameras.

When the marker-array is visible to both the HMD and the CAOS system, the relative spatial relationship between them can be calculated. This allows the HMD to accurately overlay holographic guidance information directly onto the surgeon's view of the operating site, without requiring them to constantly shift their gaze to external displays.

Experimental tests of the calibration system showed mean tracking errors of 2.03 mm and 1.12 degrees when measuring the relative pose between static marker-arrays. When using the calibration to provide holographic guidance for a simulated surgical task, the system achieved mean errors of 2.07 mm and 1.54 degrees compared to the pre-planned trajectory.

Critical Analysis

The paper presents a promising approach to integrating AR technology into the surgical workflow, but there are a few potential limitations and areas for further research:

  • The calibration and registration process is limited to situations where the infrared marker-array is visible to both the HMD and CAOS system. Occlusions or changes in the surgical scene could disrupt the alignment.
  • The experiments were conducted in a controlled lab environment, so further testing is needed to evaluate the system's performance in real-world surgical settings with more complex conditions.
  • The paper does not address potential issues around the ergonomics and usability of wearing an AR HMD during lengthy procedures, which could impact surgeon comfort and focus.
  • Broader questions remain about the overall efficacy and safety of using AR guidance in critical surgical procedures, which would require more extensive clinical trials to establish.

Overall, the research demonstrates an innovative calibration approach that could enhance the integration of AR technology into computer-assisted surgery. However, further development and validation will be needed to fully realize the potential benefits for surgical teams and patients.

Conclusion

The paper presents a calibration system that enables the seamless integration of augmented reality (AR) head-mounted displays (HMDs) with computer-assisted orthopaedic surgery (CAOS) systems. By leveraging the infrared-reflective marker-arrays already used in CAOS, the proposed method allows surgeons to maintain focus on the operating site while receiving holographic guidance, potentially improving the immersion and efficiency of these procedures.

The technical evaluation of the calibration approach demonstrates promising accuracy, with low tracking errors when registering the AR HMD to the CAOS system. However, further research is needed to assess the system's performance in real-world surgical settings and address potential limitations around occlusions, ergonomics, and broader clinical validation.

Overall, the paper contributes an innovative solution to a key challenge in bringing AR technology into the operating room, with the goal of enhancing the capabilities of computer-assisted surgery. As AR systems continue to advance, approaches like this calibration method may play an important role in seamlessly integrating these immersive tools into established medical workflows.



This summary was produced with help from an AI and may contain inaccuracies - check out the links to read the original source documents!

Follow @aimodelsfyi on š• ā†’

Related Papers

ā†—ļø

Total Score

0

Semi-Automatic Infrared Calibration for Augmented Reality Systems in Surgery

Hisham Iqbal, Ferdinando Rodriguez y Baena

Augmented reality (AR) has the potential to improve the immersion and efficiency of computer-assisted orthopaedic surgery (CAOS) by allowing surgeons to maintain focus on the operating site rather than external displays in the operating theatre. Successful deployment of AR to CAOS requires a calibration that can accurately calculate the spatial relationship between real and holographic objects. Several studies attempt this calibration through manual alignment or with additional fiducial markers in the surgical scene. We propose a calibration system that offers a direct method for the calibration of AR head-mounted displays (HMDs) with CAOS systems, by using infrared-reflective marker-arrays widely used in CAOS. In our fast, user-agnostic setup, a HoloLens 2 detected the pose of marker arrays using infrared response and time-of-flight depth obtained through sensors onboard the HMD. Registration with a commercially available CAOS system was achieved when an IR marker-array was visible to both devices. Study tests found relative-tracking mean errors of 2.03 mm and 1.12{deg} when calculating the relative pose between two static marker-arrays at short ranges. When using the calibration result to provide in-situ holographic guidance for a simulated wire-insertion task, a pre-clinical test reported mean errors of 2.07 mm and 1.54{deg} when compared to a pre-planned trajectory.

Read more

5/6/2024

A Review on Organ Deformation Modeling Approaches for Reliable Surgical Navigation using Augmented Reality
Total Score

0

A Review on Organ Deformation Modeling Approaches for Reliable Surgical Navigation using Augmented Reality

Zheng Han, Qi Dou

Augmented Reality (AR) holds the potential to revolutionize surgical procedures by allowing surgeons to visualize critical structures within the patient's body. This is achieved through superimposing preoperative organ models onto the actual anatomy. Challenges arise from dynamic deformations of organs during surgery, making preoperative models inadequate for faithfully representing intraoperative anatomy. To enable reliable navigation in augmented surgery, modeling of intraoperative deformation to obtain an accurate alignment of the preoperative organ model with the intraoperative anatomy is indispensable. Despite the existence of various methods proposed to model intraoperative organ deformation, there are still few literature reviews that systematically categorize and summarize these approaches. This review aims to fill this gap by providing a comprehensive and technical-oriented overview of modeling methods for intraoperative organ deformation in augmented reality in surgery. Through a systematic search and screening process, 112 closely relevant papers were included in this review. By presenting the current status of organ deformation modeling methods and their clinical applications, this review seeks to enhance the understanding of organ deformation modeling in AR-guided surgery, and discuss the potential topics for future advancements.

Read more

8/7/2024

Hologram: Realtime Holographic Overlays via LiDAR Augmented Reconstruction
Total Score

0

Hologram: Realtime Holographic Overlays via LiDAR Augmented Reconstruction

Ekansh Agrawal

Guided by the hologram technology of the infamous Star Wars franchise, I present an application that creates real-time holographic overlays using LiDAR augmented 3D reconstruction. Prior attempts involve SLAM or NeRFs which either require highly calibrated scenes, incur steep computation costs, or fail to render dynamic scenes. I propose 3 high-fidelity reconstruction tools that can run on a portable device, such as a iPhone 14 Pro, which can allow for metric accurate facial reconstructions. My systems enable interactive and immersive holographic experiences that can be used for a wide range of applications, including augmented reality, telepresence, and entertainment.

Read more

5/14/2024

šŸ”

Total Score

0

Fixation-based Self-calibration for Eye Tracking in VR Headsets

Ryusei Uramune, Sei Ikeda, Hiroki Ishizuka, Osamu Oshiro

This study proposes a novel self-calibration method for eye tracking in a virtual reality (VR) headset. The proposed method is based on the assumptions that the user's viewpoint can freely move and that the points of regard (PoRs) from different viewpoints are distributed within a small area on an object surface during visual fixation. In the method, fixations are first detected from the time-series data of uncalibrated gaze directions using an extension of the I-VDT (velocity and dispersion threshold identification) algorithm to a three-dimensional (3D) scene. Then, the calibration parameters are optimized by minimizing the sum of a dispersion metrics of the PoRs. The proposed method can potentially identify the optimal calibration parameters representing the user-dependent offset from the optical axis to the visual axis without explicit user calibration, image processing, or marker-substitute objects. For the gaze data of 18 participants walking in two VR environments with many occlusions, the proposed method achieved an accuracy of 2.1$^circ$, which was significantly lower than the average offset. Our method is the first self-calibration method with an average error lower than 3$^circ$ in 3D environments. Further, the accuracy of the proposed method can be improved by up to 1.2$^circ$ by refining the fixation detection or optimization algorithm.

Read more

4/24/2024