Sequence-aware Pre-training for Echocardiography Probe Guidance

Read original: arXiv:2408.15026 - Published 8/28/2024 by Haojun Jiang, Zhenguo Sun, Yu Sun, Ning Jia, Meng Li, Shaqi Luo, Shiji Song, Gao Huang
Total Score

0

Sequence-aware Pre-training for Echocardiography Probe Guidance

Sign in to get full access

or

If you already have an account, we'll log you in

Overview

  • This paper introduces a novel sequence-aware pre-training approach for echocardiography probe guidance.
  • The method leverages the temporal structure of ultrasound videos to improve model performance on probe positioning tasks.
  • The proposed technique is evaluated on several echocardiography datasets and demonstrates superior performance compared to existing methods.

Plain English Explanation

The paper describes a new way to train AI models for guiding the positioning of ultrasound probes during echocardiography (heart imaging) procedures. Echocardiography is a widely used medical imaging technique that allows doctors to see the structure and function of the heart.

Effectively positioning the ultrasound probe is crucial for obtaining high-quality images, but can be challenging for less experienced technicians. The authors' approach aims to improve probe guidance by taking advantage of the temporal structure of ultrasound video data.

Typically, AI models for probe guidance are trained on individual frames or snapshots of ultrasound images. In contrast, this new method pre-trains the model to understand the sequential patterns and dynamics present in ultrasound videos.

This sequence-aware pre-training allows the model to learn more robust and generalizable representations, which can then be fine-tuned for specific probe positioning tasks. The authors demonstrate that their approach outperforms existing methods on several benchmark datasets, highlighting the value of incorporating temporal information into the training process.

Technical Explanation

The key innovation of this work is the Sequence-aware Pre-training module, which aims to capture the temporal structure of echocardiography videos. Typical probe guidance models are trained on individual frames, but the authors hypothesize that leveraging the sequential nature of the data can lead to more effective representations.

The pre-training process involves two main steps:

  1. Temporal Prediction: The model is trained to predict the next frame in a sequence of ultrasound images. This encourages the model to learn meaningful temporal relationships in the data.

  2. Ordinal Regression: The model is also trained to predict the ordinal position of a frame within a sequence. This helps the model understand the overall structure and dynamics of the ultrasound video.

After this pre-training stage, the model can be fine-tuned on specific probe positioning tasks, such as goal-conditioned reinforcement learning for ultrasound navigation or view-agnostic echocardiography guidance. The authors show that this sequence-aware pre-training leads to significant performance improvements compared to models trained from scratch or with standard pre-training approaches.

Critical Analysis

The paper presents a compelling approach to improving echocardiography probe guidance using sequence-aware pre-training. The authors make a strong case for the importance of incorporating temporal information, which is often overlooked in this domain.

However, the paper does not address some potential limitations or areas for further research. For example, the proposed method relies on having access to high-quality ultrasound video data, which may not always be readily available, especially for rare or complex medical conditions.

Additionally, the authors do not discuss the interpretability or explainability of their approach, which could be important for building trust and acceptance in a clinical setting.

Further research could explore ways to make the sequence-aware pre-training more data-efficient, or investigate the generalization of the approach to other medical imaging modalities beyond echocardiography.

Conclusion

This paper presents a novel sequence-aware pre-training method for improving echocardiography probe guidance. By leveraging the temporal structure of ultrasound videos, the authors demonstrate significant performance gains over existing techniques.

The proposed approach has the potential to enhance the accuracy and reliability of probe positioning, which could lead to better diagnostic imaging and ultimately improved patient outcomes. While the paper does not address all possible limitations, it represents an important step forward in the field of medical image guidance and automation.



This summary was produced with help from an AI and may contain inaccuracies - check out the links to read the original source documents!

Follow @aimodelsfyi on 𝕏 →

Related Papers

Sequence-aware Pre-training for Echocardiography Probe Guidance
Total Score

0

Sequence-aware Pre-training for Echocardiography Probe Guidance

Haojun Jiang, Zhenguo Sun, Yu Sun, Ning Jia, Meng Li, Shaqi Luo, Shiji Song, Gao Huang

Cardiac ultrasound probe guidance aims to help novices adjust the 6-DOF probe pose to obtain high-quality sectional images. Cardiac ultrasound faces two major challenges: (1) the inherently complex structure of the heart, and (2) significant individual variations. Previous works have only learned the population-averaged 2D and 3D structures of the heart rather than personalized cardiac structural features, leading to a performance bottleneck. Clinically, we observed that sonographers adjust their understanding of a patient's cardiac structure based on prior scanning sequences, thereby modifying their scanning strategies. Inspired by this, we propose a sequence-aware self-supervised pre-training method. Specifically, our approach learns personalized 2D and 3D cardiac structural features by predicting the masked-out images and actions in a scanning sequence. We hypothesize that if the model can predict the missing content it has acquired a good understanding of the personalized cardiac structure. In the downstream probe guidance task, we also introduced a sequence modeling approach that models individual cardiac structural information based on the images and actions from historical scan data, enabling more accurate navigation decisions. Experiments on a large-scale dataset with 1.36 million samples demonstrated that our proposed sequence-aware paradigm can significantly reduce navigation errors, with translation errors decreasing by 15.90% to 36.87% and rotation errors decreasing by 11.13% to 20.77%, compared to state-of-the-art methods.

Read more

8/28/2024

Structure-aware World Model for Probe Guidance via Large-scale Self-supervised Pre-train
Total Score

0

Structure-aware World Model for Probe Guidance via Large-scale Self-supervised Pre-train

Haojun Jiang, Meng Li, Zhenguo Sun, Ning Jia, Yu Sun, Shaqi Luo, Shiji Song, Gao Huang

The complex structure of the heart leads to significant challenges in echocardiography, especially in acquisition cardiac ultrasound images. Successful echocardiography requires a thorough understanding of the structures on the two-dimensional plane and the spatial relationships between planes in three-dimensional space. In this paper, we innovatively propose a large-scale self-supervised pre-training method to acquire a cardiac structure-aware world model. The core innovation lies in constructing a self-supervised task that requires structural inference by predicting masked structures on a 2D plane and imagining another plane based on pose transformation in 3D space. To support large-scale pre-training, we collected over 1.36 million echocardiograms from ten standard views, along with their 3D spatial poses. In the downstream probe guidance task, we demonstrate that our pre-trained model consistently reduces guidance errors across the ten most common standard views on the test set with 0.29 million samples from 74 routine clinical scans, indicating that structure-aware pre-training benefits the scanning.

Read more

7/22/2024

Cardiac Copilot: Automatic Probe Guidance for Echocardiography with World Model
Total Score

0

Cardiac Copilot: Automatic Probe Guidance for Echocardiography with World Model

Haojun Jiang, Zhenguo Sun, Ning Jia, Meng Li, Yu Sun, Shaqi Luo, Shiji Song, Gao Huang

Echocardiography is the only technique capable of real-time imaging of the heart and is vital for diagnosing the majority of cardiac diseases. However, there is a severe shortage of experienced cardiac sonographers, due to the heart's complex structure and significant operational challenges. To mitigate this situation, we present a Cardiac Copilot system capable of providing real-time probe movement guidance to assist less experienced sonographers in conducting freehand echocardiography. This system can enable non-experts, especially in primary departments and medically underserved areas, to perform cardiac ultrasound examinations, potentially improving global healthcare delivery. The core innovation lies in proposing a data-driven world model, named Cardiac Dreamer, for representing cardiac spatial structures. This world model can provide structure features of any cardiac planes around the current probe position in the latent space, serving as an precise navigation map for autonomous plane localization. We train our model with real-world ultrasound data and corresponding probe motion from 110 routine clinical scans with 151K sample pairs by three certified sonographers. Evaluations on three standard planes with 37K sample pairs demonstrate that the world model can reduce navigation errors by up to 33% and exhibit more stable performance.

Read more

6/21/2024

Goal-conditioned reinforcement learning for ultrasound navigation guidance
Total Score

0

Goal-conditioned reinforcement learning for ultrasound navigation guidance

Abdoul Aziz Amadou, Vivek Singh, Florin C. Ghesu, Young-Ho Kim, Laura Stanciulescu, Harshitha P. Sai, Puneet Sharma, Alistair Young, Ronak Rajani, Kawal Rhode

Transesophageal echocardiography (TEE) plays a pivotal role in cardiology for diagnostic and interventional procedures. However, using it effectively requires extensive training due to the intricate nature of image acquisition and interpretation. To enhance the efficiency of novice sonographers and reduce variability in scan acquisitions, we propose a novel ultrasound (US) navigation assistance method based on contrastive learning as goal-conditioned reinforcement learning (GCRL). We augment the previous framework using a novel contrastive patient batching method (CPB) and a data-augmented contrastive loss, both of which we demonstrate are essential to ensure generalization to anatomical variations across patients. The proposed framework enables navigation to both standard diagnostic as well as intricate interventional views with a single model. Our method was developed with a large dataset of 789 patients and obtained an average error of 6.56 mm in position and 9.36 degrees in angle on a testing dataset of 140 patients, which is competitive or superior to models trained on individual views. Furthermore, we quantitatively validate our method's ability to navigate to interventional views such as the Left Atrial Appendage (LAA) view used in LAA closure. Our approach holds promise in providing valuable guidance during transesophageal ultrasound examinations, contributing to the advancement of skill acquisition for cardiac ultrasound practitioners.

Read more

8/2/2024