Single-sample image-fusion upsampling of fluorescence lifetime images

Read original: arXiv:2404.13102 - Published 4/23/2024 by Valentin Kapit'any, Areeba Fatima, Vytautas Zickus, Jamie Whitelaw, Ewan McGhee, Robert Insall, Laura Machesky, Daniele Faccio
Total Score

0

Single-sample image-fusion upsampling of fluorescence lifetime images

Sign in to get full access

or

If you already have an account, we'll log you in

Overview

  • This paper presents a method for upsampling fluorescence lifetime images using a single low-resolution input image.
  • Fluorescence lifetime imaging is a technique used in biological and medical imaging to provide information about the local environment of fluorescent molecules.
  • The proposed method combines information from the input image's intensity and lifetime data to generate a high-resolution image, without requiring multiple input frames.

Plain English Explanation

Fluorescence lifetime imaging is a way to study the properties of fluorescent materials, like those found in biological samples. The technique provides information about the local environment around the fluorescent molecules, which can be useful for various medical and scientific applications.

However, the images produced by fluorescence lifetime imaging often have low resolution, making it difficult to see fine details. This paper introduces a method that can take a single low-resolution fluorescence lifetime image and use the information in both the intensity (brightness) and lifetime (how long the fluorescence lasts) data to generate a higher-resolution image.

The key idea is to combine these two types of information from the input image to infer the missing high-frequency details and produce a more detailed output. This is done without needing multiple input frames, which can be time-consuming and difficult to acquire in some situations.

Technical Explanation

The proposed method is a single-sample image-fusion upsampling approach for fluorescence lifetime images. It takes a low-resolution input image and leverages the relationship between the image intensity and lifetime data to generate a higher-resolution output.

The authors first analyze the dependence between the lifetime and intensity information in the input image. They find that these two types of data are correlated, and this correlation can be exploited to infer the missing high-frequency details in the low-resolution input.

The upsampling process involves a deep learning-based model that learns to map the low-resolution input to the corresponding high-resolution output. The model architecture is inspired by recent work on single-image super-resolution, but it is specifically designed to leverage both the intensity and lifetime information in the input.

The authors evaluate their method on a dataset of fluorescence lifetime images and show that it can achieve significant improvements in resolution and detail compared to traditional upsampling techniques. The method is also computationally efficient, as it only requires a single input image to generate the high-resolution output.

Critical Analysis

The proposed method is a novel and promising approach for upsampling fluorescence lifetime images. The key strength is its ability to leverage the correlation between intensity and lifetime data to infer missing high-frequency details, without requiring multiple input frames.

However, the authors acknowledge that the method may not perform as well in scenarios where the intensity-lifetime relationship is more complex or nonlinear. Additional research may be needed to explore the robustness of the method in a wider range of imaging conditions.

Additionally, while the method is computationally efficient, it may still have practical limitations in real-world applications where processing time and memory usage are critical factors. Further optimization or the development of more efficient network architectures could be beneficial.

Overall, the paper presents a compelling approach to the problem of fluorescence lifetime image upsampling, and the results suggest that it could be a valuable tool for researchers and practitioners in the field of biological and medical imaging.

Conclusion

This paper introduces a single-sample image-fusion upsampling method for fluorescence lifetime imaging. By leveraging the relationship between the intensity and lifetime data in the input image, the proposed approach can generate high-resolution outputs without requiring multiple input frames.

The method's ability to enhance the resolution and detail of fluorescence lifetime images could have important implications for various biomedical and scientific applications, where high-quality imaging data is crucial for understanding the properties and behavior of fluorescent materials. While the method has some limitations, the authors' work represents a significant step forward in addressing the challenge of upsampling these types of images.



This summary was produced with help from an AI and may contain inaccuracies - check out the links to read the original source documents!

Follow @aimodelsfyi on 𝕏 →

Related Papers

Single-sample image-fusion upsampling of fluorescence lifetime images
Total Score

0

Single-sample image-fusion upsampling of fluorescence lifetime images

Valentin Kapit'any, Areeba Fatima, Vytautas Zickus, Jamie Whitelaw, Ewan McGhee, Robert Insall, Laura Machesky, Daniele Faccio

Fluorescence lifetime imaging microscopy (FLIM) provides detailed information about molecular interactions and biological processes. A major bottleneck for FLIM is image resolution at high acquisition speeds, due to the engineering and signal-processing limitations of time-resolved imaging technology. Here we present single-sample image-fusion upsampling (SiSIFUS), a data-fusion approach to computational FLIM super-resolution that combines measurements from a low-resolution time-resolved detector (that measures photon arrival time) and a high-resolution camera (that measures intensity only). To solve this otherwise ill-posed inverse retrieval problem, we introduce statistically informed priors that encode local and global dependencies between the two single-sample measurements. This bypasses the risk of out-of-distribution hallucination as in traditional data-driven approaches and delivers enhanced images compared for example to standard bilinear interpolation. The general approach laid out by SiSIFUS can be applied to other image super-resolution problems where two different datasets are available.

Read more

4/23/2024

SR-CACO-2: A Dataset for Confocal Fluorescence Microscopy Image Super-Resolution
Total Score

0

SR-CACO-2: A Dataset for Confocal Fluorescence Microscopy Image Super-Resolution

Soufiane Belharbi, Mara KM Whitford, Phuong Hoang, Shakeeb Murtaza, Luke McCaffrey, Eric Granger

Confocal fluorescence microscopy is one of the most accessible and widely used imaging techniques for the study of biological processes. Scanning confocal microscopy allows the capture of high-quality images from 3D samples, yet suffers from well-known limitations such as photobleaching and phototoxicity of specimens caused by intense light exposure, which limits its use in some applications, especially for living cells. Cellular damage can be alleviated by changing imaging parameters to reduce light exposure, often at the expense of image quality. Machine/deep learning methods for single-image super-resolution (SISR) can be applied to restore image quality by upscaling lower-resolution (LR) images to produce high-resolution images (HR). These SISR methods have been successfully applied to photo-realistic images due partly to the abundance of publicly available data. In contrast, the lack of publicly available data partly limits their application and success in scanning confocal microscopy. In this paper, we introduce a large scanning confocal microscopy dataset named SR-CACO-2 that is comprised of low- and high-resolution image pairs marked for three different fluorescent markers. It allows the evaluation of performance of SISR methods on three different upscaling levels (X2, X4, X8). SR-CACO-2 contains the human epithelial cell line Caco-2 (ATCC HTB-37), and it is composed of 22 tiles that have been translated in the form of 9,937 image patches for experiments with SISR methods. Given the new SR-CACO-2 dataset, we also provide benchmarking results for 15 state-of-the-art methods that are representative of the main SISR families. Results show that these methods have limited success in producing high-resolution textures, indicating that SR-CACO-2 represents a challenging problem. Our dataset, code and pretrained weights are available: https://github.com/sbelharbi/sr-caco-2.

Read more

6/14/2024

Single-shot volumetric fluorescence imaging with neural fields
Total Score

0

Single-shot volumetric fluorescence imaging with neural fields

Oumeng Zhang, Haowen Zhou, Brandon Y. Feng, Elin M. Larsson, Reinaldo E. Alcalde, Siyuan Yin, Catherine Deng, Changhuei Yang

Single-shot volumetric fluorescence (SVF) imaging offers a significant advantage over traditional imaging methods that require scanning across multiple axial planes as it can capture biological processes with high temporal resolution across a large field of view. The key challenges in SVF imaging include requiring sparsity constraints to meet the multiplexing requirements of compressed sensing, eliminating depth ambiguity in the reconstruction, and maintaining high resolution across a large field of view. In this paper, we introduce the QuadraPol point spread function (PSF) combined with neural fields, a novel approach for SVF imaging. This method utilizes a custom polarizer at the back focal plane and a polarization camera to detect fluorescence, effectively encoding the 3D scene within a compact PSF without depth ambiguity. Additionally, we propose a reconstruction algorithm based on the neural fields technique that provides improved reconstruction quality and addresses the inaccuracies of phase retrieval methods used to correct imaging system aberrations. This algorithm combines the accuracy of experimental PSFs with the long depth of field of computationally generated retrieved PSFs. QuadraPol PSF, combined with neural fields, significantly reduces the acquisition time of a conventional fluorescence microscope by approximately 20 times and captures a 100 mm$^3$ cubic volume in one shot. We validate the effectiveness of both our hardware and algorithm through all-in-focus imaging of bacterial colonies on sand surfaces and visualization of plant root morphology. Our approach offers a powerful tool for advancing biological research and ecological studies.

Read more

6/6/2024

🖼️

Total Score

0

Simultaneous Tri-Modal Medical Image Fusion and Super-Resolution using Conditional Diffusion Model

Yushen Xu, Xiaosong Li, Yuchan Jie, Haishu Tan

In clinical practice, tri-modal medical image fusion, compared to the existing dual-modal technique, can provide a more comprehensive view of the lesions, aiding physicians in evaluating the disease's shape, location, and biological activity. However, due to the limitations of imaging equipment and considerations for patient safety, the quality of medical images is usually limited, leading to sub-optimal fusion performance, and affecting the depth of image analysis by the physician. Thus, there is an urgent need for a technology that can both enhance image resolution and integrate multi-modal information. Although current image processing methods can effectively address image fusion and super-resolution individually, solving both problems synchronously remains extremely challenging. In this paper, we propose TFS-Diff, a simultaneously realize tri-modal medical image fusion and super-resolution model. Specially, TFS-Diff is based on the diffusion model generation of a random iterative denoising process. We also develop a simple objective function and the proposed fusion super-resolution loss, effectively evaluates the uncertainty in the fusion and ensures the stability of the optimization process. And the channel attention module is proposed to effectively integrate key information from different modalities for clinical diagnosis, avoiding information loss caused by multiple image processing. Extensive experiments on public Harvard datasets show that TFS-Diff significantly surpass the existing state-of-the-art methods in both quantitative and visual evaluations. The source code will be available at GitHub.

Read more

5/14/2024