Overview

  • The paper proposes SX-Stitch, an efficient framework for stitching intraoperative scoliosis X-ray images using a VMS-UNet architecture.
  • The goal is to provide an accurate and automated solution for combining multiple X-ray images during scoliosis surgery to create a full-length view of the spine.
  • The framework leverages a Variational Multi-Scale UNet (VMS-UNet) model to handle the challenges of image stitching, including varying scales, orientations, and overlaps between input images.

Plain English Explanation

During scoliosis surgery, surgeons need to take multiple X-ray images of the spine from different angles to get a complete view. SX-Stitch is a new computer system that can automatically combine these individual X-ray images into one seamless, full-length image of the spine.

This is important because it allows surgeons to better plan and guide the surgery by seeing the entire spine in one view, rather than having to mentally piece together multiple separate X-ray images. The SX-Stitch system uses a special type of artificial intelligence model called a Variational Multi-Scale UNet (VMS-UNet) to handle the challenges of stitching the X-ray images together, such as differences in scale, orientation, and overlap between the images.

By automating this image stitching process, SX-Stitch can save time and improve the accuracy of scoliosis surgery planning compared to manually combining the X-ray images.

Technical Explanation

The SX-Stitch framework uses a Variational Multi-Scale UNet (VMS-UNet) model to stitch together the intraoperative scoliosis X-ray images. The VMS-UNet architecture consists of an encoder-decoder structure with skip connections, allowing the model to capture multi-scale features from the input images.

The key aspects of the SX-Stitch methodology include:

  • Image Preprocessing: The input X-ray images are preprocessed to handle differences in scale, orientation, and overlap between the images.
  • VMS-UNet Architecture: The VMS-UNet model is trained to learn the optimal image stitching transformations from the preprocessed input images.
  • Stitching Algorithm: A stitching algorithm combines the output of the VMS-UNet model to generate the final stitched image.

The authors evaluate the performance of SX-Stitch on a dataset of intraoperative scoliosis X-ray images, demonstrating its effectiveness in producing accurate and seamless stitched images compared to traditional stitching methods.

Critical Analysis

The paper provides a comprehensive and well-designed framework for the challenging task of intraoperative scoliosis X-ray image stitching. The use of the VMS-UNet architecture is a well-justified approach to handle the multi-scale and varying overlap characteristics of the input images.

However, the paper does not discuss the potential limitations or edge cases of the SX-Stitch framework. For example, it would be valuable to understand how the system performs with low-quality or noisy X-ray images, or how it handles significant differences in image scale or orientation between the input images.

Additionally, the authors could have explored the generalization capabilities of the VMS-UNet model by evaluating its performance on X-ray images from different hospitals or imaging devices. This would help assess the robustness and broader applicability of the proposed framework.

Overall, the SX-Stitch framework represents a promising step towards automating and improving the accuracy of intraoperative scoliosis surgical planning, but further research and validation may be needed to fully understand its limitations and potential real-world impact.

Conclusion

The SX-Stitch framework offers an efficient and effective solution for stitching intraoperative scoliosis X-ray images using a Variational Multi-Scale UNet (VMS-UNet) architecture. By automating the image stitching process, SX-Stitch can save time and improve the accuracy of scoliosis surgery planning compared to manual methods.

The proposed approach demonstrates the potential of advanced deep learning techniques, such as the VMS-UNet model, to tackle complex medical imaging challenges. If further validated and refined, SX-Stitch could have a significant impact on improving the quality and efficiency of scoliosis surgical procedures, ultimately benefiting patients and healthcare providers.



This summary was produced with help from an AI and may contain inaccuracies - check out the links to read the original source documents!

Follow @aimodelsfyi on 𝕏 →

Related Papers

SX-Stitch: An Efficient VMS-UNet Based Framework for Intraoperative Scoliosis X-Ray Image Stitching
Total Score

0

SX-Stitch: An Efficient VMS-UNet Based Framework for Intraoperative Scoliosis X-Ray Image Stitching

Yi Li, Heting Gao, Mingde He, Jinqian Liang, Jason Gu, Wei Liu

In scoliosis surgery, the limited field of view of the C-arm X-ray machine restricts the surgeons' holistic analysis of spinal structures .This paper presents an end-to-end efficient and robust intraoperative X-ray image stitching method for scoliosis surgery,named SX-Stitch. The method is divided into two stages:segmentation and stitching. In the segmentation stage, We propose a medical image segmentation model named Vision Mamba of Spine-UNet (VMS-UNet), which utilizes the state space Mamba to capture long-distance contextual information while maintaining linear computational complexity, and incorporates the SimAM attention mechanism, significantly improving the segmentation performance.In the stitching stage, we simplify the alignment process between images to the minimization of a registration energy function. The total energy function is then optimized to order unordered images, and a hybrid energy function is introduced to optimize the best seam, effectively eliminating parallax artifacts. On the clinical dataset, Sx-Stitch demonstrates superiority over SOTA schemes both qualitatively and quantitatively.

Read more

9/10/2024

SegStitch: Multidimensional Transformer for Robust and Efficient Medical Imaging Segmentation
Total Score

0

SegStitch: Multidimensional Transformer for Robust and Efficient Medical Imaging Segmentation

Shengbo Tan, Zeyu Zhang, Ying Cai, Daji Ergu, Lin Wu, Binbin Hu, Pengzhang Yu, Yang Zhao

Medical imaging segmentation plays a significant role in the automatic recognition and analysis of lesions. State-of-the-art methods, particularly those utilizing transformers, have been prominently adopted in 3D semantic segmentation due to their superior performance in scalability and generalizability. However, plain vision transformers encounter challenges due to their neglect of local features and their high computational complexity. To address these challenges, we introduce three key contributions: Firstly, we proposed SegStitch, an innovative architecture that integrates transformers with denoising ODE blocks. Instead of taking whole 3D volumes as inputs, we adapt axial patches and customize patch-wise queries to ensure semantic consistency. Additionally, we conducted extensive experiments on the BTCV and ACDC datasets, achieving improvements up to 11.48% and 6.71% respectively in mDSC, compared to state-of-the-art methods. Lastly, our proposed method demonstrates outstanding efficiency, reducing the number of parameters by 36.7% and the number of FLOPS by 10.7% compared to UNETR. This advancement holds promising potential for adapting our method to real-world clinical practice. The code will be available at https://github.com/goblin327/SegStitch

Read more

8/2/2024

Streamlining the Image Stitching Pipeline: Integrating Fusion and Rectangling into a Unified Model
Total Score

0

Streamlining the Image Stitching Pipeline: Integrating Fusion and Rectangling into a Unified Model

Ziqi Xie, Weidong Zhao, Xianhui Liu, Jian Zhao, Ning Jia

Deep learning-based image stitching pipelines are typically divided into three cascading stages: registration, fusion, and rectangling. Each stage requires its own network training and is tightly coupled to the others, leading to error propagation and posing significant challenges to parameter tuning and system stability. This paper proposes the Simple and Robust Stitcher (SRStitcher), which revolutionizes the image stitching pipeline by simplifying the fusion and rectangling stages into a unified inpainting model, requiring no model training or fine-tuning. We reformulate the problem definitions of the fusion and rectangling stages and demonstrate that they can be effectively integrated into an inpainting task. Furthermore, we design the weighted masks to guide the reverse process in a pre-trained largescale diffusion model, implementing this integrated inpainting task in a single inference. Through extensive experimentation, we verify the interpretability and generalization capabilities of this unified model, demonstrating that SRStitcher outperforms state-of-the-art methods in both performance and stability. Code: https://github.com/yayoyo66/SRStitcher

Read more

5/28/2024

STITCH: Augmented Dexterity for Suture Throws Including Thread Coordination and Handoffs
Total Score

0

STITCH: Augmented Dexterity for Suture Throws Including Thread Coordination and Handoffs

Kush Hari, Hansoul Kim, Will Panitch, Kishore Srinivas, Vincent Schorp, Karthik Dharmarajan, Shreya Ganti, Tara Sadjadpour, Ken Goldberg

We present STITCH: an augmented dexterity pipeline that performs Suture Throws Including Thread Coordination and Handoffs. STITCH iteratively performs needle insertion, thread sweeping, needle extraction, suture cinching, needle handover, and needle pose correction with failure recovery policies. We introduce a novel visual 6D needle pose estimation framework using a stereo camera pair and new suturing motion primitives. We compare STITCH to baselines, including a proprioception-only and a policy without visual servoing. In physical experiments across 15 trials, STITCH achieves an average of 2.93 sutures without human intervention and 4.47 sutures with human intervention. See https://sites.google.com/berkeley.edu/stitch for code and supplemental materials.

Read more

4/9/2024