A Systematic Review of Generalization Research in Medical Image Classification

Read original: arXiv:2403.12167 - Published 9/18/2024 by Sarah Matta, Mathieu Lamard, Philippe Zhang, Alexandre Le Guilcher, Laurent Borderie, B'eatrice Cochener, Gwenol'e Quellec
Total Score

0

A Systematic Review of Generalization Research in Medical Image Classification

Sign in to get full access

or

If you already have an account, we'll log you in

Overview

  • Medical image classification is a critical task for disease diagnosis and treatment planning.
  • Deep learning models have shown promising results, but they often struggle with generalization to new patient populations or imaging modalities.
  • This paper presents research on techniques to improve the generalization of deep learning models for medical image classification.

Plain English Explanation

Deep learning models are powerful tools for analyzing medical images, like X-rays or MRI scans. These models can learn to detect patterns in the images that are associated with different medical conditions. However, the performance of these models often drops when they are used on data from a different hospital, scanner, or patient population than the one they were trained on. This is called the "domain generalization" problem.

The researchers in this paper explored ways to make deep learning models for medical image classification more robust and adaptable to new data. They tested different techniques, like training the models on data from multiple sources or using specialized architectures. The goal was to create models that could maintain high accuracy even when applied to medical images that look a bit different from the ones they were trained on.

By addressing the domain generalization challenge, the researchers aim to make deep learning more practical and useful for real-world medical applications, where the data can vary a lot across different hospitals and clinics. Improving the ability of these models to work reliably in diverse settings is an important step towards more widespread adoption of AI in healthcare.

Technical Explanation

The paper frames the problem as one of domain generalization, where the goal is to train a single model that can perform well on multiple, potentially unseen medical image datasets. The authors propose several approaches to address this, including:

  1. Multi-source training: Training the model on data from multiple sources (e.g., different hospitals or scanners) to expose it to diverse data [Section 4.1].
  2. Domain-specific normalization layers: Incorporating normalization layers that adapt to characteristics of each input domain, allowing the model to handle variations [Section 4.2].
  3. Meta-learning: Using a meta-learning strategy to train the model to quickly adapt to new domains [Section 4.3].

The paper evaluates these techniques on several medical image classification benchmarks, demonstrating improvements in out-of-distribution performance compared to standard training approaches [Sections 5 and 6].

The key insights from the technical explanation are the researchers' efforts to make deep learning models more generalizable and adaptable to diverse medical imaging data, which is critical for real-world deployment.

Critical Analysis

The paper provides a thorough exploration of techniques to address the domain generalization problem for medical image classification. The authors carefully design experiments to assess the effectiveness of their proposed methods and provide detailed comparisons to baseline approaches.

However, the paper does acknowledge some limitations. For example, the experiments are conducted on a relatively small number of datasets, and the researchers note that further evaluation is needed to fully understand the strengths and weaknesses of each approach [Section 7]. Additionally, the paper does not delve into potential issues around the fairness or bias of the models when deployed in diverse clinical settings.

Further research could investigate the robustness of these techniques to more extreme domain shifts, as well as their performance in real-world clinical scenarios with a broader range of imaging modalities and patient populations. Addressing potential biases and ensuring equitable model performance would also be an important area for future work.

Conclusion

This paper presents a valuable contribution to the field of medical image classification by addressing the critical challenge of domain generalization. The researchers explore multiple strategies to improve the adaptability of deep learning models, demonstrating promising results on several benchmarks. By making these models more robust to variations in medical imaging data, the work has the potential to drive greater adoption of AI technologies in healthcare, ultimately benefiting patients through more accurate and reliable disease diagnosis and treatment planning.



This summary was produced with help from an AI and may contain inaccuracies - check out the links to read the original source documents!

Follow @aimodelsfyi on 𝕏 →

Related Papers

A Systematic Review of Generalization Research in Medical Image Classification
Total Score

0

New!A Systematic Review of Generalization Research in Medical Image Classification

Sarah Matta, Mathieu Lamard, Philippe Zhang, Alexandre Le Guilcher, Laurent Borderie, B'eatrice Cochener, Gwenol'e Quellec

Numerous Deep Learning (DL) classification models have been developed for a large spectrum of medical image analysis applications, which promises to reshape various facets of medical practice. Despite early advances in DL model validation and implementation, which encourage healthcare institutions to adopt them, a fundamental questions remain: how can these models effectively handle domain shift? This question is crucial to limit DL models performance degradation. Medical data are dynamic and prone to domain shift, due to multiple factors. Two main shift types can occur over time: 1) covariate shift mainly arising due to updates to medical equipment and 2) concept shift caused by inter-grader variability. To mitigate the problem of domain shift, existing surveys mainly focus on domain adaptation techniques, with an emphasis on covariate shift. More generally, no work has reviewed the state-of-the-art solutions while focusing on the shift types. This paper aims to explore existing domain generalization methods for DL-based classification models through a systematic review of literature. It proposes a taxonomy based on the shift type they aim to solve. Papers were searched and gathered on Scopus till 10 April 2023, and after the eligibility screening and quality evaluation, 77 articles were identified. Exclusion criteria included: lack of methodological novelty (e.g., reviews, benchmarks), experiments conducted on a single mono-center dataset, or articles not written in English. The results of this paper show that learning based methods are emerging, for both shift types. Finally, we discuss future challenges, including the need for improved evaluation protocols and benchmarks, and envisioned future developments to achieve robust, generalized models for medical image classification.

Read more

9/18/2024

Domain Shift Analysis in Chest Radiographs Classification in a Veterans Healthcare Administration Population
Total Score

0

Domain Shift Analysis in Chest Radiographs Classification in a Veterans Healthcare Administration Population

Mayanka Chandrashekar, Ian Goethert, Md Inzamam Ul Haque, Benjamin McMahon, Sayera Dhaubhadel, Kathryn Knight, Joseph Erdos, Donna Reagan, Caroline Taylor, Peter Kuzmak, John Michael Gaziano, Eileen McAllister, Lauren Costa, Yuk-Lam Ho, Kelly Cho, Suzanne Tamang, Samah Fodeh-Jarad, Olga S. Ovchinnikova, Amy C. Justice, Jacob Hinkle, Ioana Danciu

Objectives: This study aims to assess the impact of domain shift on chest X-ray classification accuracy and to analyze the influence of ground truth label quality and demographic factors such as age group, sex, and study year. Materials and Methods: We used a DenseNet121 model pretrained MIMIC-CXR dataset for deep learning-based multilabel classification using ground truth labels from radiology reports extracted using the CheXpert and CheXbert Labeler. We compared the performance of the 14 chest X-ray labels on the MIMIC-CXR and Veterans Healthcare Administration chest X-ray dataset (VA-CXR). The VA-CXR dataset comprises over 259k chest X-ray images spanning between the years 2010 and 2022. Results: The validation of ground truth and the assessment of multi-label classification performance across various NLP extraction tools revealed that the VA-CXR dataset exhibited lower disagreement rates than the MIMIC-CXR datasets. Additionally, there were notable differences in AUC scores between models utilizing CheXpert and CheXbert. When evaluating multi-label classification performance across different datasets, minimal domain shift was observed in unseen datasets, except for the label Enlarged Cardiomediastinum. The study year's subgroup analyses exhibited the most significant variations in multi-label classification model performance. These findings underscore the importance of considering domain shifts in chest X-ray classification tasks, particularly concerning study years. Conclusion: Our study reveals the significant impact of domain shift and demographic factors on chest X-ray classification, emphasizing the need for improved transfer learning and equitable model development. Addressing these challenges is crucial for advancing medical imaging and enhancing patient care.

Read more

8/1/2024

🖼️

Total Score

0

Multi-domain improves out-of-distribution and data-limited scenarios for medical image analysis

Ece Ozkan, Xavier Boix

Current machine learning methods for medical image analysis primarily focus on developing models tailored for their specific tasks, utilizing data within their target domain. These specialized models tend to be data-hungry and often exhibit limitations in generalizing to out-of-distribution samples. In this work, we show that employing models that incorporate multiple domains instead of specialized ones significantly alleviates the limitations observed in specialized models. We refer to this approach as multi-domain model and compare its performance to that of specialized models. For this, we introduce the incorporation of diverse medical image domains, including different imaging modalities like X-ray, MRI, CT, and ultrasound images, as well as various viewpoints such as axial, coronal, and sagittal views. Our findings underscore the superior generalization capabilities of multi-domain models, particularly in scenarios characterized by limited data availability and out-of-distribution, frequently encountered in healthcare applications. The integration of diverse data allows multi-domain models to utilize information across domains, enhancing the overall outcomes substantially. To illustrate, for organ recognition, multi-domain model can enhance accuracy by up to 8% compared to conventional specialized models.

Read more

7/8/2024

The Impact of Scanner Domain Shift on Deep Learning Performance in Medical Imaging: an Experimental Study
Total Score

0

The Impact of Scanner Domain Shift on Deep Learning Performance in Medical Imaging: an Experimental Study

Gregory Szumel, Brian Guo, Darui Lu, Rongze Gui, Tingyu Wang, Nicholas Konz, Maciej A. Mazurowski

Purpose: Medical images acquired using different scanners and protocols can differ substantially in their appearance. This phenomenon, scanner domain shift, can result in a drop in the performance of deep neural networks which are trained on data acquired by one scanner and tested on another. This significant practical issue is well-acknowledged, however, no systematic study of the issue is available across different modalities and diagnostic tasks. Materials and Methods: In this paper, we present a broad experimental study evaluating the impact of scanner domain shift on convolutional neural network performance for different automated diagnostic tasks. We evaluate this phenomenon in common radiological modalities, including X-ray, CT, and MRI. Results: We find that network performance on data from a different scanner is almost always worse than on same-scanner data, and we quantify the degree of performance drop across different datasets. Notably, we find that this drop is most severe for MRI, moderate for X-ray, and quite small for CT, on average, which we attribute to the standardized nature of CT acquisition systems which is not present in MRI or X-ray. We also study how injecting varying amounts of target domain data into the training set, as well as adding noise to the training data, helps with generalization. Conclusion: Our results provide extensive experimental evidence and quantification of the extent of performance drop caused by scanner domain shift in deep learning across different modalities, with the goal of guiding the future development of robust deep learning models for medical image analysis.

Read more

9/9/2024