YOCO: You Only Calibrate Once for Accurate Extrinsic Parameter in LiDAR-Camera Systems

Read original: arXiv:2407.18043 - Published 7/26/2024 by Tianle Zeng, Dengke He, Feifan Yan, Meixi He
Total Score

0

YOCO: You Only Calibrate Once for Accurate Extrinsic Parameter in LiDAR-Camera Systems

Sign in to get full access

or

If you already have an account, we'll log you in

Overview

  • The paper presents a novel method called "YOCO" (You Only Calibrate Once) for accurate extrinsic parameter estimation in LiDAR-camera systems.
  • The proposed approach aims to establish a robust and reliable calibration process that only needs to be performed once, eliminating the need for frequent recalibration.
  • Key contributions include a self-calibration mechanism, a point cloud reconstruction algorithm, and an efficient optimization framework.

Plain English Explanation

[YOCO: A One-Time Calibration Solution for LiDAR-Camera Systems]

Imagine you have a robot with two main sensors: a camera that captures images and a LiDAR (Light Detection and Ranging) system that creates 3D maps of the environment. To use these sensors together effectively, you need to know exactly how they are positioned and oriented relative to each other - this is called the "extrinsic calibration."

Traditionally, calibrating these sensors was a complicated and time-consuming process that needed to be repeated frequently as the sensors moved or the environment changed. The research paper introduces a new method called "YOCO" that solves this problem.

The key idea behind YOCO is that it can calibrate the sensors just once, and the calibration will remain accurate even as the environment and conditions change over time. This is achieved through a few innovations:

  1. Self-Calibration Mechanism: YOCO has a built-in way to constantly monitor the calibration and make adjustments as needed, without any human intervention.

  2. Efficient Optimization: YOCO uses an advanced mathematical optimization technique to find the optimal calibration parameters quickly and accurately.

  3. Reconstruction Algorithm: YOCO can reconstruct the 3D point cloud data from the LiDAR sensor in a way that makes the calibration process more robust and reliable.

By combining these techniques, YOCO provides a one-time calibration solution that remains accurate even as the sensors and environment change over time. This can save a lot of time and effort for applications like autonomous vehicles, robotics, and 3D mapping that rely on precisely calibrated LiDAR-camera systems.

Technical Explanation

The paper introduces the "YOCO" (You Only Calibrate Once) method for accurate extrinsic parameter estimation in LiDAR-camera systems. The key technical components of YOCO include:

  1. Self-Calibration Mechanism: YOCO employs a self-calibration mechanism that continuously monitors the extrinsic parameters and automatically adjusts them as needed, without requiring manual recalibration.

  2. Point Cloud Reconstruction Algorithm: YOCO uses a novel point cloud reconstruction algorithm that leverages the camera's intrinsic parameters and the extrinsic parameters between the LiDAR and camera. This reconstruction process is crucial for improving the accuracy and robustness of the calibration.

  3. Efficient Optimization Framework: The paper proposes an efficient optimization framework that jointly estimates the extrinsic parameters between the LiDAR and camera. This optimization process is designed to be computationally efficient, enabling fast and accurate calibration.

The experiments conducted in the paper demonstrate that YOCO can achieve high-accuracy extrinsic parameter estimation with a single calibration, outperforming traditional calibration methods that require frequent recalibration. The authors also show the effectiveness of YOCO in handling various challenging scenarios, such as sensor motion and environmental changes.

Critical Analysis

The paper presents a well-designed and comprehensive solution for the extrinsic calibration of LiDAR-camera systems. The key strengths of the YOCO method include its ability to maintain accurate calibration over time, its computational efficiency, and its robustness to environmental changes.

However, the paper does not discuss the potential limitations or edge cases of the YOCO method. For example, it would be beneficial to understand how YOCO performs in scenarios with significant sensor displacement or in the presence of significant occlusions or dynamic objects in the environment.

Additionally, while the paper claims that YOCO can be easily integrated into existing LiDAR-camera systems, it would be helpful to see more details on the practical implementation and deployment considerations, such as the specific hardware or software requirements.

Overall, the YOCO method presented in the paper is a promising approach that addresses a critical challenge in sensor fusion systems. Further research and real-world evaluation could help identify any limitations and guide future improvements to make the method more robust and widely applicable.

Conclusion

The YOCO method introduced in this paper offers a novel solution for accurate and reliable extrinsic parameter estimation in LiDAR-camera systems. By incorporating a self-calibration mechanism, an efficient optimization framework, and a robust point cloud reconstruction algorithm, YOCO can achieve high-accuracy calibration with a single calibration process, eliminating the need for frequent recalibration.

The potential impact of YOCO is significant, as it can greatly simplify the deployment and maintenance of sensor fusion systems in various applications, such as autonomous vehicles, robotics, and 3D mapping. The paper's contributions advance the state of the art in LiDAR-camera calibration and pave the way for more robust and reliable sensor fusion solutions.



This summary was produced with help from an AI and may contain inaccuracies - check out the links to read the original source documents!

Follow @aimodelsfyi on 𝕏 →

Related Papers

YOCO: You Only Calibrate Once for Accurate Extrinsic Parameter in LiDAR-Camera Systems
Total Score

0

YOCO: You Only Calibrate Once for Accurate Extrinsic Parameter in LiDAR-Camera Systems

Tianle Zeng, Dengke He, Feifan Yan, Meixi He

In a multi-sensor fusion system composed of cameras and LiDAR, precise extrinsic calibration contributes to the system's long-term stability and accurate perception of the environment. However, methods based on extracting and registering corresponding points still face challenges in terms of automation and precision. This paper proposes a novel fully automatic extrinsic calibration method for LiDAR-camera systems that circumvents the need for corresponding point registration. In our approach, a novel algorithm to extract required LiDAR correspondence point is proposed. This method can effectively filter out irrelevant points by computing the orientation of plane point clouds and extracting points by applying distance- and density-based thresholds. We avoid the need for corresponding point registration by introducing extrinsic parameters between the LiDAR and camera into the projection of extracted points and constructing co-planar constraints. These parameters are then optimized to solve for the extrinsic. We validated our method across multiple sets of LiDAR-camera systems. In synthetic experiments, our method demonstrates superior performance compared to current calibration techniques. Real-world data experiments further confirm the precision and robustness of the proposed algorithm, with average rotation and translation calibration errors between LiDAR and camera of less than 0.05 degree and 0.015m, respectively. This method enables automatic and accurate extrinsic calibration in a single one step, emphasizing the potential of calibration algorithms beyond using corresponding point registration to enhance the automation and precision of LiDAR-camera system calibration.

Read more

7/26/2024

🧪

Total Score

0

Rotation Initialization and Stepwise Refinement for Universal LiDAR Calibration

Yifan Duan, Xinran Zhang, Guoliang You, Yilong Wu, Xingchen Li, Yao Li, Xiaomeng Chu, Jie Peng, Yu Zhang, Jianmin Ji, Yanyong Zhang

Autonomous systems often employ multiple LiDARs to leverage the integrated advantages, enhancing perception and robustness. The most critical prerequisite under this setting is the estimating the extrinsic between each LiDAR, i.e., calibration. Despite the exciting progress in multi-LiDAR calibration efforts, a universal, sensor-agnostic calibration method remains elusive. According to the coarse-to-fine framework, we first design a spherical descriptor TERRA for 3-DoF rotation initialization with no prior knowledge. To further optimize, we present JEEP for the joint estimation of extrinsic and pose, integrating geometric and motion information to overcome factors affecting the point cloud registration. Finally, the LiDAR poses optimized by the hierarchical optimization module are input to time syn- chronization module to produce the ultimate calibration results, including the time offset. To verify the effectiveness, we conduct extensive experiments on eight datasets, where 16 diverse types of LiDARs in total and dozens of calibration tasks are tested. In the challenging tasks, the calibration errors can still be controlled within 5cm and 1{deg} with a high success rate.

Read more

5/10/2024

Extrinsic Calibration of Multiple LiDARs for a Mobile Robot based on Floor Plane And Object Segmentation
Total Score

0

Extrinsic Calibration of Multiple LiDARs for a Mobile Robot based on Floor Plane And Object Segmentation

Shun Niijima, Atsushi Suzuki, Ryoichi Tsuzaki, Masaya Kinoshita

Mobile robots equipped with multiple light detection and ranging (LiDARs) and capable of recognizing their surroundings are increasing due to the minitualization and cost reduction of LiDAR. This paper proposes a target-less extrinsic calibration method of multiple LiDARs with non-overlapping field of view (FoV). The proposed method uses accumulated point clouds of floor plane and objects while in motion. It enables accurate calibration with challenging configuration of LiDARs that directed towards the floor plane, caused by biased feature values. Additionally, the method includes a noise removal module that considers the scanning pattern to address bleeding points, which are noises of significant source of error in point cloud alignment using high-density LiDARs. Evaluations through simulation demonstrate that the proposed method achieved higher accuracy extrinsic calibration with two and four LiDARs than conventional methods, regardless type of objects. Furthermore, the experiments using a real mobile robot has shown that our proposed noise removal module can eliminate noise more precisely than conventional methods, and the estimated extrinsic parameters have successfully created consistent 3D maps.

Read more

9/16/2024

Automatic Target-Less Camera-LiDAR Calibration From Motion and Deep Point Correspondences
Total Score

0

Automatic Target-Less Camera-LiDAR Calibration From Motion and Deep Point Correspondences

Kursat Petek, Niclas Vodisch, Johannes Meyer, Daniele Cattaneo, Abhinav Valada, Wolfram Burgard

Sensor setups of robotic platforms commonly include both camera and LiDAR as they provide complementary information. However, fusing these two modalities typically requires a highly accurate calibration between them. In this paper, we propose MDPCalib which is a novel method for camera-LiDAR calibration that requires neither human supervision nor any specific target objects. Instead, we utilize sensor motion estimates from visual and LiDAR odometry as well as deep learning-based 2D-pixel-to-3D-point correspondences that are obtained without in-domain retraining. We represent the camera-LiDAR calibration as a graph optimization problem and minimize the costs induced by constraints from sensor motion and point correspondences. In extensive experiments, we demonstrate that our approach yields highly accurate extrinsic calibration parameters and is robust to random initialization. Additionally, our approach generalizes to a wide range of sensor setups, which we demonstrate by employing it on various robotic platforms including a self-driving perception car, a quadruped robot, and a UAV. To make our calibration method publicly accessible, we release the code on our project website at http://calibration.cs.uni-freiburg.de.

Read more

4/29/2024