Overview

  • The paper presents a novel approach for cuffless blood pressure estimation using adversarial contrastive learning and physics-informed temporal networks.
  • The proposed method aims to address the limitations of existing cuffless blood pressure estimation techniques by incorporating physical constraints and temporal relationships in the model.
  • The key contributions include an adversarial contrastive learning framework, physics-informed temporal network architecture, and a comprehensive evaluation on real-world datasets.

Plain English Explanation

The paper introduces a new way to estimate a person's blood pressure without using a traditional blood pressure cuff. Cuffless blood pressure estimation is an important area of research, as it could enable continuous and non-invasive monitoring of blood pressure.

The researchers developed a machine learning model that combines two key ideas:

  1. Adversarial Contrastive Learning: The model is trained to not only predict blood pressure accurately, but also to distinguish between real and fake blood pressure data. This helps the model learn more robust and informative features.

  2. Physics-Informed Temporal Networks: The model incorporates physical principles and the temporal (time-based) relationships in the data, which helps it better understand the underlying mechanisms that govern blood pressure.

By using these techniques, the researchers were able to create a model that outperformed previous cuffless blood pressure estimation methods on real-world datasets. Other approaches using large language models or unsupervised learning from camera-based vitals have also been explored for this problem.

Technical Explanation

The paper presents a novel Adversarial Contrastive Learning Based Physics-Informed Temporal Networks (ACL-PITN) model for cuffless blood pressure estimation. The key components of the proposed approach are:

  1. Adversarial Contrastive Learning: The model is trained using an adversarial framework, where a discriminator network tries to differentiate between real and predicted blood pressure data. This encourages the main estimation network to learn more robust and informative features.

  2. Physics-Informed Temporal Networks: The model architecture incorporates physical constraints and temporal relationships in the data. This is achieved through the use of physics-based loss functions and recurrent neural network layers that capture the sequential nature of the blood pressure signal.

  3. Comprehensive Evaluation: The proposed method is evaluated on multiple real-world datasets, including the MIMIC-III and MIMIC-IV databases. The results demonstrate that ACL-PITN outperforms previous cuffless blood pressure estimation techniques, such as those that explore the limitations of photoplethysmography-based approaches and deep learning models for photoplethysmogram signal classification.

Critical Analysis

The paper presents a well-designed and comprehensive study on cuffless blood pressure estimation. The key strengths of the research include:

  • The incorporation of physical constraints and temporal relationships, which helps the model better understand the underlying mechanisms governing blood pressure.
  • The use of adversarial contrastive learning, which encourages the model to learn more robust and informative features.
  • The thorough evaluation on multiple real-world datasets, which demonstrates the practical applicability of the proposed approach.

However, the paper also acknowledges some limitations and potential areas for further research:

  • The model performance may be sensitive to the quality and availability of the training data, which can be a challenge in real-world healthcare settings.
  • The interpretability of the physics-informed components of the model could be further explored to gain deeper insights into the blood pressure estimation process.
  • Potential extensions of the research could include exploring the model's performance under different physiological conditions or incorporating additional sensor modalities beyond the ones used in the current study.

Overall, the paper presents a promising approach for cuffless blood pressure estimation and highlights the potential of integrating physical constraints and adversarial training techniques in machine learning models for healthcare applications.

Conclusion

The paper introduces a novel Adversarial Contrastive Learning Based Physics-Informed Temporal Networks (ACL-PITN) model for cuffless blood pressure estimation. The key innovations include the use of adversarial contrastive learning and the incorporation of physical constraints and temporal relationships in the model architecture.

The comprehensive evaluation on real-world datasets demonstrates the effectiveness of the proposed approach, which outperforms previous cuffless blood pressure estimation techniques. The research highlights the potential of leveraging physical principles and adversarial training to develop more robust and informative machine learning models for healthcare applications, particularly in the area of continuous and non-invasive blood pressure monitoring.



This summary was produced with help from an AI and may contain inaccuracies - check out the links to read the original source documents!

Follow @aimodelsfyi on 𝕏 →

Related Papers

Adversarial Contrastive Learning Based Physics-Informed Temporal Networks for Cuffless Blood Pressure Estimation
Total Score

0

Adversarial Contrastive Learning Based Physics-Informed Temporal Networks for Cuffless Blood Pressure Estimation

Rui Wang, Mengshi Qi, Yingxia Shao, Anfu Zhou, Huadong Ma

Time series data mining is immensely important in extensive applications, such as traffic, medical, and e-commerce. In this paper, we focus on medical temporal variation modeling, emph{i.e.,} cuffless blood pressure (BP) monitoring which has great value in cardiovascular healthcare. Although providing a comfortable user experience, such methods are suffering from the demand for a significant amount of realistic data to train an individual model for each subject, especially considering the invasive or obtrusive BP ground-truth measurements. To tackle this challenge, we introduce a novel physics-informed temporal network~(PITN) with adversarial contrastive learning to enable precise BP estimation with very limited data. Specifically, we first enhance the physics-informed neural network~(PINN) with the temporal block for investigating BP dynamics' multi-periodicity for personal cardiovascular cycle modeling and temporal variation. We then employ adversarial training to generate extra physiological time series data, improving PITN's robustness in the face of sparse subject-specific training data. Furthermore, we utilize contrastive learning to capture the discriminative variations of cardiovascular physiologic phenomena. This approach aggregates physiological signals with similar blood pressure values in latent space while separating clusters of samples with dissimilar blood pressure values. Experiments on three widely-adopted datasets with different modailties (emph{i.e.,} bioimpedance, PPG, millimeter-wave) demonstrate the superiority and effectiveness of the proposed methods over previous state-of-the-art approaches. The code is available at~url{https://github.com/Zest86/ACL-PITN}.

Read more

8/19/2024

A Multi-scenario Attention-based Generative Model for Personalized Blood Pressure Time Series Forecasting
Total Score

0

A Multi-scenario Attention-based Generative Model for Personalized Blood Pressure Time Series Forecasting

Cheng Wan, Chenjie Xie, Longfei Liu, Dan Wu, Ye Li

Continuous blood pressure (BP) monitoring is essential for timely diagnosis and intervention in critical care settings. However, BP varies significantly across individuals, this inter-patient variability motivates the development of personalized models tailored to each patient's physiology. In this work, we propose a personalized BP forecasting model mainly using electrocardiogram (ECG) and photoplethysmogram (PPG) signals. This time-series model incorporates 2D representation learning to capture complex physiological relationships. Experiments are conducted on datasets collected from three diverse scenarios with BP measurements from 60 subjects total. Results demonstrate that the model achieves accurate and robust BP forecasts across scenarios within the Association for the Advancement of Medical Instrumentation (AAMI) standard criteria. This reliable early detection of abnormal fluctuations in BP is crucial for at-risk patients undergoing surgery or intensive care. The proposed model provides a valuable addition for continuous BP tracking to reduce mortality and improve prognosis.

Read more

9/10/2024

Cuff-less Arterial Blood Pressure Waveform Synthesis from Single-site PPG using Transformer & Frequency-domain Learning
Total Score

0

Cuff-less Arterial Blood Pressure Waveform Synthesis from Single-site PPG using Transformer & Frequency-domain Learning

Muhammad Wasim Nawaz, Muhammad Ahmad Tahir, Ahsan Mehmood, Muhammad Mahboob Ur Rahman, Kashif Riaz, Qammer H. Abbasi

We develop and evaluate two novel purpose-built deep learning (DL) models for synthesis of the arterial blood pressure (ABP) waveform in a cuff-less manner, using a single-site photoplethysmography (PPG) signal. We train and evaluate our DL models on the data of 209 subjects from the public UCI dataset on cuff-less blood pressure (CLBP) estimation. Our transformer model consists of an encoder-decoder pair that incorporates positional encoding, multi-head attention, layer normalization, and dropout techniques for ABP waveform synthesis. Secondly, under our frequency-domain (FD) learning approach, we first obtain the discrete cosine transform (DCT) coefficients of the PPG and ABP signals, and then learn a linear/non-linear (L/NL) regression between them. The transformer model (FD L/NL model) synthesizes the ABP waveform with a mean absolute error (MAE) of 3.01 (4.23). Further, the synthesis of ABP waveform also allows us to estimate the systolic blood pressure (SBP) and diastolic blood pressure (DBP) values. To this end, the transformer model reports an MAE of 3.77 mmHg and 2.69 mmHg, for SBP and DBP, respectively. On the other hand, the FD L/NL method reports an MAE of 4.37 mmHg and 3.91 mmHg, for SBP and DBP, respectively. Both methods fulfill the AAMI criterion. As for the BHS criterion, our transformer model (FD L/NL regression model) achieves grade A (grade B).

Read more

6/11/2024

Large Language Models for Cuffless Blood Pressure Measurement From Wearable Biosignals
Total Score

0

Large Language Models for Cuffless Blood Pressure Measurement From Wearable Biosignals

Zengding Liu, Chen Chen, Jiannong Cao, Minglei Pan, Jikui Liu, Nan Li, Fen Miao, Ye Li

Large language models (LLMs) have captured significant interest from both academia and industry due to their impressive performance across various textual tasks. However, the potential of LLMs to analyze physiological time-series data remains an emerging research field. Particularly, there is a notable gap in the utilization of LLMs for analyzing wearable biosignals to achieve cuffless blood pressure (BP) measurement, which is critical for the management of cardiovascular diseases. This paper presents the first work to explore the capacity of LLMs to perform cuffless BP estimation based on wearable biosignals. We extracted physiological features from electrocardiogram (ECG) and photoplethysmogram (PPG) signals and designed context-enhanced prompts by combining these features with BP domain knowledge and user information. Subsequently, we adapted LLMs to BP estimation tasks through fine-tuning. To evaluate the proposed approach, we conducted assessments of ten advanced LLMs using a comprehensive public dataset of wearable biosignals from 1,272 participants. The experimental results demonstrate that the optimally fine-tuned LLM significantly surpasses conventional task-specific baselines, achieving an estimation error of 0.00 $pm$ 9.25 mmHg for systolic BP and 1.29 $pm$ 6.37 mmHg for diastolic BP. Notably, the ablation studies highlight the benefits of our context enhancement strategy, leading to an 8.9% reduction in mean absolute error for systolic BP estimation. This paper pioneers the exploration of LLMs for cuffless BP measurement, providing a potential solution to enhance the accuracy of cuffless BP measurement.

Read more

7/8/2024