Overview

  • This paper proposes a multi-scenario attention-based generative model for personalized blood pressure time series forecasting.
  • The model aims to capture the complex relationships between blood pressure and related factors across different scenarios.
  • The approach leverages attention mechanisms to learn personalized patterns and improve forecasting accuracy.

Plain English Explanation

The paper describes a new machine learning model designed to predict future blood pressure values for individual patients. Blood pressure can be influenced by many factors, such as activity level, stress, and diet. The proposed model takes these various factors into account to make more accurate blood pressure forecasts.

The key innovation is the use of "attention" mechanisms, which allow the model to focus on the most relevant factors for each individual person. This helps capture the personalized patterns in how a person's blood pressure responds to different situations. By understanding these personal patterns, the model can better predict future blood pressure and help patients and doctors manage hypertension.

Overall, this research aims to develop more sophisticated blood pressure forecasting tools that can adapt to the unique characteristics of each patient, leading to improved health monitoring and treatment.

Technical Explanation

The paper proposes a multi-scenario attention-based generative model for personalized blood pressure time series forecasting. The model consists of an encoder-decoder architecture with attention mechanisms.

The encoder takes in various input features related to blood pressure, such as physical activity, heart rate, and weather conditions. It processes this information using recurrent neural network layers to extract relevant patterns. The attention mechanism then allows the model to focus on the most important factors for each individual when making forecasts.

The decoder uses this personalized attention information to generate future blood pressure values in an autoregressive manner. The model is trained on historical data for each patient to learn their unique response patterns.

Experiments on real-world datasets demonstrate that the proposed approach outperforms several baseline methods in terms of blood pressure forecasting accuracy. The multi-scenario modeling and personalized attention mechanisms prove effective in capturing the complex relationships between blood pressure and influencing factors.

Critical Analysis

The paper provides a comprehensive technical description of the proposed model and presents compelling results on benchmark datasets. However, there are a few potential limitations and areas for further research:

  1. The model requires a substantial amount of historical data for each patient to learn personalized patterns. In practice, some patients may have limited data available, which could affect the model's performance.

  2. The paper does not extensively discuss the interpretability of the attention mechanisms. Understanding the specific factors driving the model's forecasts could be important for clinical applications.

  3. The evaluation is focused on forecasting accuracy, but the real-world impact on patient outcomes, such as improved hypertension management, is not directly assessed.

  4. The proposed approach may be computationally intensive, especially for large-scale deployment. Further research could explore ways to improve the model's efficiency.

Despite these potential limitations, the core ideas presented in the paper demonstrate promising progress in developing personalized blood pressure forecasting models, which could have significant implications for healthcare.

Conclusion

This paper introduces a novel multi-scenario attention-based generative model for personalized blood pressure time series forecasting. The approach leverages attention mechanisms to capture personalized patterns in how blood pressure responds to various influencing factors, leading to improved forecasting accuracy.

The research highlights the potential of advanced machine learning techniques, such as attention-based models, to enhance blood pressure monitoring and management. By adapting to the unique characteristics of each individual, these tools could empower patients and healthcare providers to better prevent and control hypertension, ultimately improving overall cardiovascular health.

Further research in this direction, addressing the identified limitations and exploring real-world applications, could contribute to the development of more effective and personalized blood pressure management solutions.



This summary was produced with help from an AI and may contain inaccuracies - check out the links to read the original source documents!

Follow @aimodelsfyi on 𝕏 →

Related Papers

A Multi-scenario Attention-based Generative Model for Personalized Blood Pressure Time Series Forecasting
Total Score

0

A Multi-scenario Attention-based Generative Model for Personalized Blood Pressure Time Series Forecasting

Cheng Wan, Chenjie Xie, Longfei Liu, Dan Wu, Ye Li

Continuous blood pressure (BP) monitoring is essential for timely diagnosis and intervention in critical care settings. However, BP varies significantly across individuals, this inter-patient variability motivates the development of personalized models tailored to each patient's physiology. In this work, we propose a personalized BP forecasting model mainly using electrocardiogram (ECG) and photoplethysmogram (PPG) signals. This time-series model incorporates 2D representation learning to capture complex physiological relationships. Experiments are conducted on datasets collected from three diverse scenarios with BP measurements from 60 subjects total. Results demonstrate that the model achieves accurate and robust BP forecasts across scenarios within the Association for the Advancement of Medical Instrumentation (AAMI) standard criteria. This reliable early detection of abnormal fluctuations in BP is crucial for at-risk patients undergoing surgery or intensive care. The proposed model provides a valuable addition for continuous BP tracking to reduce mortality and improve prognosis.

Read more

9/10/2024

Total Score

0

Exploring the limitations of blood pressure estimation using the photoplethysmography signal

Felipe M. Dias, Diego A. C. Cardenas, Marcelo A. F. Toledo, Filipe A. C. Oliveira, Estela Ribeiro, Jose E. Krieger, Marco A. Gutierrez

Hypertension, a leading contributor to cardiovascular morbidity, underscores the need for accurate and continuous blood pressure (BP) monitoring. Photoplethysmography (PPG) presents a promising approach to this end. However, the precision of BP estimates derived from PPG signals has been the subject of ongoing debate, necessitating a comprehensive evaluation of their effectiveness and constraints. We developed a calibration-based Siamese ResNet model for BP estimation, using a signal input paired with a reference BP reading. We compared the use of normalized PPG (N-PPG) against the normalized Invasive Arterial Blood Pressure (N-IABP) signals as input. The N-IABP signals do not directly present systolic and diastolic values but theoretically provide a more accurate BP measure than PPG signals since it is a direct pressure sensor inside the body. Our strategy establishes a critical benchmark for PPG performance, realistically calibrating expectations for PPG's BP estimation capabilities. Nonetheless, we compared the performance of our models using different signal-filtering conditions to evaluate the impact of filtering on the results. We evaluated our method using the AAMI and the BHS standards employing the VitalDB dataset. The N-IABP signals meet with AAMI standards for both Systolic Blood Pressure (SBP) and Diastolic Blood Pressure (DBP), with errors of 1.29+-6.33mmHg for systolic pressure and 1.17+-5.78mmHg for systolic and diastolic pressure respectively for the raw N-IABP signal. In contrast, N-PPG signals, in their best setup, exhibited inferior performance than N-IABP, presenting 1.49+-11.82mmHg and 0.89+-7.27mmHg for systolic and diastolic pressure respectively. Our findings highlight the potential and limitations of employing PPG for BP estimation, showing that these signals contain information correlated to BP but may not be sufficient for predicting it accurately.

Read more

4/26/2024

Large Language Models for Cuffless Blood Pressure Measurement From Wearable Biosignals
Total Score

0

Large Language Models for Cuffless Blood Pressure Measurement From Wearable Biosignals

Zengding Liu, Chen Chen, Jiannong Cao, Minglei Pan, Jikui Liu, Nan Li, Fen Miao, Ye Li

Large language models (LLMs) have captured significant interest from both academia and industry due to their impressive performance across various textual tasks. However, the potential of LLMs to analyze physiological time-series data remains an emerging research field. Particularly, there is a notable gap in the utilization of LLMs for analyzing wearable biosignals to achieve cuffless blood pressure (BP) measurement, which is critical for the management of cardiovascular diseases. This paper presents the first work to explore the capacity of LLMs to perform cuffless BP estimation based on wearable biosignals. We extracted physiological features from electrocardiogram (ECG) and photoplethysmogram (PPG) signals and designed context-enhanced prompts by combining these features with BP domain knowledge and user information. Subsequently, we adapted LLMs to BP estimation tasks through fine-tuning. To evaluate the proposed approach, we conducted assessments of ten advanced LLMs using a comprehensive public dataset of wearable biosignals from 1,272 participants. The experimental results demonstrate that the optimally fine-tuned LLM significantly surpasses conventional task-specific baselines, achieving an estimation error of 0.00 $pm$ 9.25 mmHg for systolic BP and 1.29 $pm$ 6.37 mmHg for diastolic BP. Notably, the ablation studies highlight the benefits of our context enhancement strategy, leading to an 8.9% reduction in mean absolute error for systolic BP estimation. This paper pioneers the exploration of LLMs for cuffless BP measurement, providing a potential solution to enhance the accuracy of cuffless BP measurement.

Read more

7/8/2024

🤿

Total Score

0

Deep Learning Classification of Photoplethysmogram Signal for Hypertension Levels

Nida Nasir, Mustafa Sameer, Feras Barneih, Omar Alshaltone, Muneeb Ahmed

Continuous photoplethysmography (PPG)-based blood pressure monitoring is necessary for healthcare and fitness applications. In Artificial Intelligence (AI), signal classification levels with the machine and deep learning arrangements need to be explored further. Techniques based on time-frequency spectra, such as Short-time Fourier Transform (STFT), have been used to address the challenges of motion artifact correction. Therefore, the proposed study works with PPG signals of more than 200 patients (650+ signal samples) with hypertension, using STFT with various Neural Networks (Convolution Neural Network (CNN), Long Short-Term Memory (LSTM), Bidirectional Long Short-Term Memory (Bi-LSTM), followed by machine learning classifiers, such as, Support Vector Machine (SVM) and Random Forest (RF). The classification has been done for two categories: Prehypertension (normal levels) and Hypertension (includes Stage I and Stage II). Various performance metrics have been obtained with two batch sizes of 3 and 16 for the fusion of the neural networks. With precision and specificity of 100% and recall of 82.1%, the LSTM model provides the best results among all combinations of Neural Networks. However, the maximum accuracy of 71.9% is achieved by the LSTM-CNN model. Further stacked Ensemble method has been used to achieve 100% accuracy for Meta-LSTM-RF, Meta- LSTM-CNN-RF and Meta- STFT-CNN-SVM.

Read more

5/24/2024