Artificial Intelligence in Gastrointestinal Bleeding Analysis for Video Capsule Endoscopy: Insights, Innovations, and Prospects (2008-2023)

Read original: arXiv:2409.00639 - Published 9/4/2024 by Tanisha Singh, Shreshtha Jha, Nidhi Bhatt, Palak Handa, Nidhi Goel, Sreedevi Indu
Total Score

0

Artificial Intelligence in Gastrointestinal Bleeding Analysis for Video Capsule Endoscopy: Insights, Innovations, and Prospects (2008-2023)

Sign in to get full access

or

If you already have an account, we'll log you in

Overview

  • This paper provides an overview of the use of artificial intelligence (AI) in the analysis of gastrointestinal bleeding for video capsule endoscopy from 2008 to 2023.
  • It covers key insights, innovations, and prospects in this field.
  • The paper examines how machine learning and deep learning techniques have been applied to improve the detection and classification of gastrointestinal bleeding in video capsule endoscopy.

Plain English Explanation

Video capsule endoscopy is a medical procedure where a patient swallows a small, pill-shaped camera that takes pictures of the digestive tract as it moves through the body. This can be useful for detecting issues like gastrointestinal bleeding, which is when there is bleeding somewhere in the digestive system.

Researchers have been exploring how AI can be used to analyze the images and video from these video capsule endoscopy procedures. Machine learning and deep learning techniques have been applied to try to automatically detect and classify signs of gastrointestinal bleeding. This could help doctors review the large amount of data from these procedures more efficiently.

The paper looks at the key developments in this area over the past 15 years, including the insights researchers have gained, the innovative AI models and techniques that have been explored, and the future prospects for using AI to improve video capsule endoscopy analysis. The use of AI for image-based analysis of other medical conditions provides context for how this work fits into the broader field.

Technical Explanation

The paper provides a comprehensive review of the application of AI, particularly machine learning and deep learning, to the analysis of gastrointestinal bleeding in video capsule endoscopy data. It covers the period from 2008 to 2023, highlighting the key insights, innovations, and future prospects in this area.

The review examines how researchers have leveraged various AI techniques, such as convolutional neural networks and foundational models, to improve the detection and classification of gastrointestinal bleeding in video capsule endoscopy data. The paper discusses the performance of these AI models, their advantages over traditional manual review, and the challenges encountered in developing robust and generalizable systems.

Additionally, the review explores the role of specialized datasets in advancing the field, as well as the integration of AI into the broader clinical workflow for video capsule endoscopy analysis and its potential impact on patient care.

Critical Analysis

The paper provides a thorough and well-structured review of the use of AI in the analysis of gastrointestinal bleeding for video capsule endoscopy. It acknowledges the limitations of the current research, such as the need for larger and more diverse datasets, the potential for biases in the AI models, and the challenges of deploying these systems in real-world clinical settings.

The paper also highlights areas for further research, such as the integration of AI with other imaging modalities, the development of interpretable and explainable AI models, and the exploration of novel deep learning architectures and techniques tailored to the unique characteristics of video capsule endoscopy data.

While the paper presents a comprehensive overview of the field, it would be useful to see a more critical discussion of the potential ethical and privacy concerns associated with the use of AI in medical imaging, particularly regarding the handling of sensitive patient data and the transparency of the decision-making process.

Conclusion

This paper offers a valuable and timely review of the use of AI in the analysis of gastrointestinal bleeding for video capsule endoscopy. It highlights the significant progress made in this field over the past 15 years, as well as the promising future prospects for further enhancing the capabilities of AI-based systems in this domain.

The insights and innovations discussed in the paper have the potential to improve the efficiency and accuracy of video capsule endoscopy analysis, ultimately leading to better patient outcomes and more effective healthcare delivery. As the field continues to evolve, the paper provides a solid foundation for understanding the current state of the art and identifying opportunities for future research and development.



This summary was produced with help from an AI and may contain inaccuracies - check out the links to read the original source documents!

Follow @aimodelsfyi on 𝕏 →

Related Papers

Artificial Intelligence in Gastrointestinal Bleeding Analysis for Video Capsule Endoscopy: Insights, Innovations, and Prospects (2008-2023)
Total Score

0

Artificial Intelligence in Gastrointestinal Bleeding Analysis for Video Capsule Endoscopy: Insights, Innovations, and Prospects (2008-2023)

Tanisha Singh, Shreshtha Jha, Nidhi Bhatt, Palak Handa, Nidhi Goel, Sreedevi Indu

The escalating global mortality and morbidity rates associated with gastrointestinal (GI) bleeding, compounded by the complexities and limitations of traditional endoscopic methods, underscore the urgent need for a critical review of current methodologies used for addressing this condition. With an estimated 300,000 annual deaths worldwide, the demand for innovative diagnostic and therapeutic strategies is paramount. The introduction of Video Capsule Endoscopy (VCE) has marked a significant advancement, offering a comprehensive, non-invasive visualization of the digestive tract that is pivotal for detecting bleeding sources unattainable by traditional methods. Despite its benefits, the efficacy of VCE is hindered by diagnostic challenges, including time-consuming analysis and susceptibility to human error. This backdrop sets the stage for exploring Machine Learning (ML) applications in automating GI bleeding detection within capsule endoscopy, aiming to enhance diagnostic accuracy, reduce manual labor, and improve patient outcomes. Through an exhaustive analysis of 113 papers published between 2008 and 2023, this review assesses the current state of ML methodologies in bleeding detection, highlighting their effectiveness, challenges, and prospective directions. It contributes an in-depth examination of AI techniques in VCE frame analysis, offering insights into open-source datasets, mathematical performance metrics, and technique categorization. The paper sets a foundation for future research to overcome existing challenges, advancing gastrointestinal diagnostics through interdisciplinary collaboration and innovation in ML applications.

Read more

9/4/2024

🤖

Total Score

0

Towards Full Integration of Artificial Intelligence in Colon Capsule Endoscopy's Pathway

Esmaeil S. Nadimi, Jan-Matthias Braun, Benedicte Schelde-Olesen, Emile Prudhomme, Victoria Blanes-Vidal, Gunnar Baatrup

Despite recent surge of interest in deploying colon capsule endoscopy (CCE) for early diagnosis of colorectal diseases, there remains a large gap between the current state of CCE in clinical practice, and the state of its counterpart optical colonoscopy (OC). Our study is aimed at closing this gap, by focusing on the full integration of AI in CCE's pathway, where image processing steps linked to the detection, localization and characterisation of important findings are carried out autonomously using various AI algorithms. We developed a recognition network, that with an impressive sensitivity of 99.9%, a specificity of 99.4%, and a negative predictive value (NPV) of 99.8%, detected colorectal polyps. After recognising a polyp within a sequence of images, only those images containing polyps were fed into two parallel independent networks for characterisation, and estimation of the size of those important findings. The characterisation network reached a sensitivity of 82% and a specificity of 80% in classifying polyps to two groups, namely neoplastic vs. non-neoplastic. The size estimation network reached an accuracy of 88% in correctly segmenting the polyps. By automatically incorporating this crucial information into CCE's pathway, we moved a step closer towards the full integration of AI in CCE's routine clinical practice.

Read more

6/17/2024

WCEbleedGen: A wireless capsule endoscopy dataset and its benchmarking for automatic bleeding classification, detection, and segmentation
Total Score

0

WCEbleedGen: A wireless capsule endoscopy dataset and its benchmarking for automatic bleeding classification, detection, and segmentation

Palak Handa, Manas Dhir, Amirreza Mahbod, Florian Schwarzhans, Ramona Woitek, Nidhi Goel, Deepak Gunjan

Computer-based analysis of Wireless Capsule Endoscopy (WCE) is crucial. However, a medically annotated WCE dataset for training and evaluation of automatic classification, detection, and segmentation of bleeding and non-bleeding frames is currently lacking. The present work focused on development of a medically annotated WCE dataset called WCEbleedGen for automatic classification, detection, and segmentation of bleeding and non-bleeding frames. It comprises 2,618 WCE bleeding and non-bleeding frames which were collected from various internet resources and existing WCE datasets. A comprehensive benchmarking and evaluation of the developed dataset was done using nine classification-based, three detection-based, and three segmentation-based deep learning models. The dataset is of high-quality, is class-balanced and contains single and multiple bleeding sites. Overall, our standard benchmark results show that Visual Geometric Group (VGG) 19, You Only Look Once version 8 nano (YOLOv8n), and Link network (Linknet) performed best in automatic classification, detection, and segmentation-based evaluations, respectively. Automatic bleeding diagnosis is crucial for WCE video interpretations. This diverse dataset will aid in developing of real-time, multi-task learning-based innovative solutions for automatic bleeding diagnosis in WCE. The dataset and code are publicly available at https://zenodo.org/records/10156571 and https://github.com/misahub2023/Benchmarking-Codes-of-the-WCEBleedGen-dataset.

Read more

8/23/2024

Classification of Endoscopy and Video Capsule Images using CNN-Transformer Model
Total Score

0

Classification of Endoscopy and Video Capsule Images using CNN-Transformer Model

Aliza Subedi, Smriti Regmi, Nisha Regmi, Bhumi Bhusal, Ulas Bagci, Debesh Jha

Gastrointestinal cancer is a leading cause of cancer-related incidence and death, making it crucial to develop novel computer-aided diagnosis systems for early detection and enhanced treatment. Traditional approaches rely on the expertise of gastroenterologists to identify diseases; however, this process is subjective, and interpretation can vary even among expert clinicians. Considering recent advancements in classifying gastrointestinal anomalies and landmarks in endoscopic and video capsule endoscopy images, this study proposes a hybrid model that combines the advantages of Transformers and Convolutional Neural Networks (CNNs) to enhance classification performance. Our model utilizes DenseNet201 as a CNN branch to extract local features and integrates a Swin Transformer branch for global feature understanding, combining both to perform the classification task. For the GastroVision dataset, our proposed model demonstrates excellent performance with Precision, Recall, F1 score, Accuracy, and Matthews Correlation Coefficient (MCC) of 0.8320, 0.8386, 0.8324, 0.8386, and 0.8191, respectively, showcasing its robustness against class imbalance and surpassing other CNNs as well as the Swin Transformer model. Similarly, for the Kvasir-Capsule, a large video capsule endoscopy dataset, our model outperforms all others, achieving overall Precision, Recall, F1 score, Accuracy, and MCC of 0.7007, 0.7239, 0.6900, 0.7239, and 0.3871. Moreover, we generated saliency maps to explain our model's focus areas, demonstrating its reliable decision-making process. The results underscore the potential of our hybrid CNN-Transformer model in aiding the early and accurate detection of gastrointestinal (GI) anomalies.

Read more

8/21/2024