Automatic Robot Hand-Eye Calibration Enabled by Learning-Based 3D Vision

Read original: arXiv:2311.01335 - Published 9/6/2024 by Leihui Li, Xingyu Yang, Riwei Wang, Xuping Zhang
Total Score

0

👀

Sign in to get full access

or

If you already have an account, we'll log you in

Overview

  • Hand-eye calibration is a fundamental task in vision-based robotic systems
  • It aims to estimate the transformation matrix between the camera and robot flange
  • Most approaches rely on external markers or human assistance
  • This paper proposes a novel methodology called LRBO (Look at Robot Base Once) to address this problem without external objects or human support

Plain English Explanation

The paper presents a new method called LRBO for calibrating the hand-eye relationship between a camera and a robotic arm. Hand-eye calibration is important for vision-based robotics, as it allows the robot to understand how the camera's view relates to the position of the robot's "hand" or end-effector.

Traditionally, this calibration process has required special markers or assistance from a human operator. However, the LRBO method does away with these requirements. Instead, it uses 3D point cloud data of the robot's base to determine the transformation between the camera and the robot. This is done by leveraging machine learning algorithms to detect and register the location and orientation of the robot base.

The key advantage of this approach is that it can be done automatically, without the need for external objects or human intervention. The paper reports that the LRBO method achieved high accuracy, with translation and rotation errors of less than 1 mm and 0.3 degrees respectively. Additionally, the calibration process can be completed in around 1 second, making it the fastest 3D hand-eye calibration method compared to other approaches.

Technical Explanation

The paper proposes a novel hand-eye calibration method called LRBO (Look at Robot Base Once) that does not require external calibration objects or human assistance. Instead, the method uses 3D point cloud data of the robot base to estimate the transformation matrix between the camera and the robot flange.

The key steps of the LRBO method are:

  1. Acquiring 3D point cloud data of the robot base using a structured light scanner
  2. Employing learning-based 3D detection and registration algorithms to estimate the location and orientation of the robot base
  3. Establishing the transformation matrix I=AXB, where A represents the camera-to-robot-base transformation and B represents the robot base-to-flange transformation

The robustness and accuracy of the LRBO method are evaluated through ground-truth-based experiments across varying joint configurations. The results show a translation deviation of 0.930 mm and a rotation deviation of 0.265 degrees, outperforming other 3D vision-based calibration methods. Additionally, the 3D reconstruction experiments demonstrate a rotation error of 0.994 degrees and a position error of 1.697 mm. Importantly, the LRBO method can complete the calibration process in around 1 second, making it the fastest 3D hand-eye calibration approach compared to other techniques.

Critical Analysis

The paper presents a compelling and innovative approach to the hand-eye calibration problem, addressing the limitations of existing methods that rely on external markers or human assistance. The LRBO method's ability to perform the calibration process automatically, without the need for additional hardware or human intervention, is a significant advantage.

The authors have thoroughly evaluated the accuracy and robustness of the LRBO method through extensive experiments, demonstrating its superior performance compared to other 3D vision-based calibration techniques. The fast completion time of around 1 second is another impressive feature, making the method well-suited for practical applications.

However, the paper does not address potential limitations or areas for further research. For example, the method's performance in real-world scenarios with dynamic or cluttered environments, or its scalability to larger robotic systems, is not discussed. Additionally, the paper does not compare the LRBO method to traditional, marker-based hand-eye calibration approaches in terms of accuracy, robustness, or other relevant metrics.

Overall, the LRBO method represents a significant advancement in the field of hand-eye calibration, and the authors have demonstrated its effectiveness through rigorous experimentation. Further exploration of the method's limitations and its application in more complex real-world settings could help solidify its position as a valuable tool for vision-based robotics.

Conclusion

The paper presents a novel hand-eye calibration method called LRBO that addresses the limitations of existing approaches by using 3D point cloud data of the robot base instead of external calibration objects or human assistance. The LRBO method achieves high accuracy, with translation and rotation errors of less than 1 mm and 0.3 degrees, respectively, and can complete the calibration process in around 1 second, making it the fastest 3D hand-eye calibration technique compared to other methods.

This innovative approach to hand-eye calibration has the potential to significantly streamline the setup and integration of vision-based robotic systems, reducing the time and effort required for the calibration process. The authors' release of the LRBO code on GitHub further contributes to the accessibility and adoption of this method, which could have a meaningful impact on the field of robotics and vision-based applications.



This summary was produced with help from an AI and may contain inaccuracies - check out the links to read the original source documents!

Follow @aimodelsfyi on 𝕏 →

Related Papers

👀

Total Score

0

Automatic Robot Hand-Eye Calibration Enabled by Learning-Based 3D Vision

Leihui Li, Xingyu Yang, Riwei Wang, Xuping Zhang

Hand-eye calibration, as a fundamental task in vision-based robotic systems, aims to estimate the transformation matrix between the coordinate frame of the camera and the robot flange. Most approaches to hand-eye calibration rely on external markers or human assistance. We proposed Look at Robot Base Once (LRBO), a novel methodology that addresses the hand-eye calibration problem without external calibration objects or human support, but with the robot base. Using point clouds of the robot base, a transformation matrix from the coordinate frame of the camera to the robot base is established as I=AXB. To this end, we exploit learning-based 3D detection and registration algorithms to estimate the location and orientation of the robot base. The robustness and accuracy of the method are quantified by ground-truth-based evaluation, and the accuracy result is compared with other 3D vision-based calibration methods. To assess the feasibility of our methodology, we carried out experiments utilizing a low-cost structured light scanner across varying joint configurations and groups of experiments. The proposed hand-eye calibration method achieved a translation deviation of 0.930 mm and a rotation deviation of 0.265 degrees according to the experimental results. Additionally, the 3D reconstruction experiments demonstrated a rotation error of 0.994 degrees and a position error of 1.697 mm. Moreover, our method offers the potential to be completed in 1 second, which is the fastest compared to other 3D hand-eye calibration methods. Code is released at github.com/leihui6/LRBO.

Read more

9/6/2024

Multi-Camera Hand-Eye Calibration for Human-Robot Collaboration in Industrial Robotic Workcells
Total Score

0

Multi-Camera Hand-Eye Calibration for Human-Robot Collaboration in Industrial Robotic Workcells

Davide Allegro, Matteo Terreran, Stefano Ghidoni

In industrial scenarios, effective human-robot collaboration relies on multi-camera systems to robustly monitor human operators despite the occlusions that typically show up in a robotic workcell. In this scenario, precise localization of the person in the robot coordinate system is essential, making the hand-eye calibration of the camera network critical. This process presents significant challenges when high calibration accuracy should be achieved in short time to minimize production downtime, and when dealing with extensive camera networks used for monitoring wide areas, such as industrial robotic workcells. Our paper introduces an innovative and robust multi-camera hand-eye calibration method, designed to optimize each camera's pose relative to both the robot's base and to each other camera. This optimization integrates two types of key constraints: i) a single board-to-end-effector transformation, and ii) the relative camera-to-camera transformations. We demonstrate the superior performance of our method through comprehensive experiments employing the METRIC dataset and real-world data collected on industrial scenarios, showing notable advancements over state-of-the-art techniques even using less than 10 images. Additionally, we release an open-source version of our multi-camera hand-eye calibration algorithm at https://github.com/davidea97/Multi-Camera-Hand-Eye-Calibration.git.

Read more

6/18/2024

On Flange-based 3D Hand-Eye Calibration for Soft Robotic Tactile Welding
Total Score

0

On Flange-based 3D Hand-Eye Calibration for Soft Robotic Tactile Welding

Xudong Han, Ning Guo, Yu Jie, He Wang, Fang Wan, Chaoyang Song

This paper investigates the direct application of standardized designs on the robot for conducting robot hand-eye calibration by employing 3D scanners with collaborative robots. The well-established geometric features of the robot flange are exploited by directly capturing its point cloud data. In particular, an iterative method is proposed to facilitate point cloud processing toward a refined calibration outcome. Several extensive experiments are conducted over a range of collaborative robots, including Universal Robots UR5 & UR10 e-series, Franka Emika, and AUBO i5 using an industrial-grade 3D scanner Photoneo Phoxi S & M and a commercial-grade 3D scanner Microsoft Azure Kinect DK. Experimental results show that translational and rotational errors converge efficiently to less than 0.28 mm and 0.25 degrees, respectively, achieving a hand-eye calibration accuracy as high as the camera's resolution, probing the hardware limit. A welding seam tracking system is presented, combining the flange-based calibration method with soft tactile sensing. The experiment results show that the system enables the robot to adjust its motion in real-time, ensuring consistent weld quality and paving the way for more efficient and adaptable manufacturing processes.

Read more

7/30/2024

Kalib: Markerless Hand-Eye Calibration with Keypoint Tracking
Total Score

0

Kalib: Markerless Hand-Eye Calibration with Keypoint Tracking

Tutian Tang, Minghao Liu, Wenqiang Xu, Cewu Lu

Hand-eye calibration involves estimating the transformation between the camera and the robot. Traditional methods rely on fiducial markers, involving much manual labor and careful setup. Recent advancements in deep learning offer markerless techniques, but they present challenges, including the need for retraining networks for each robot, the requirement of accurate mesh models for data generation, and the need to address the sim-to-real gap. In this letter, we propose Kalib, an automatic and universal markerless hand-eye calibration pipeline that leverages the generalizability of visual foundation models to eliminate these barriers. In each calibration process, Kalib uses keypoint tracking and proprioceptive sensors to estimate the transformation between a robot's coordinate space and its corresponding points in camera space. Our method does not require training new networks or access to mesh models. Through evaluations in simulation environments and the real-world dataset DROID, Kalib demonstrates superior accuracy compared to recent baseline methods. This approach provides an effective and flexible calibration process for various robot systems by simplifying setup and removing dependency on precise physical markers.

Read more

8/21/2024