On Flange-based 3D Hand-Eye Calibration for Soft Robotic Tactile Welding

Read original: arXiv:2407.16041 - Published 7/30/2024 by Xudong Han, Ning Guo, Yu Jie, He Wang, Fang Wan, Chaoyang Song
Total Score

0

On Flange-based 3D Hand-Eye Calibration for Soft Robotic Tactile Welding

Sign in to get full access

or

If you already have an account, we'll log you in

Overview

  • This paper presents a method for 3D hand-eye calibration of soft robotic systems used for tactile welding applications.
  • The key focus is on using the robot's flange as the reference frame for calibration, rather than external tracking systems or visual markers.
  • The proposed approach aims to improve the accuracy and robustness of calibration for real-world welding tasks.

Plain English Explanation

In robotic systems, hand-eye calibration is the process of determining the precise spatial relationship between the robot's "hand" (end-effector) and the "eye" (sensor or camera). This calibration is crucial for tasks like human-robot interaction and visual servoing.

The authors of this paper recognized that traditional calibration methods, which often rely on external tracking systems or visual markers, can be challenging to apply in the context of soft robotic welding systems. These systems typically operate in unstructured environments without easy access to calibration references.

To address this, the researchers developed a new approach that uses the robot's own flange (the mounting interface at the end of the robot arm) as the reference frame for calibration. By leveraging the known geometry of the flange, they were able to estimate the hand-eye transformation without the need for additional sensors or markers.

This flange-based calibration method offers several key benefits:

  • Improved Accuracy: By using the flange as a reference, the calibration can achieve higher precision, as it avoids the potential errors introduced by external tracking systems.
  • Robustness: The approach is less sensitive to environmental factors, such as lighting conditions or occlusions, making it more reliable for real-world welding tasks.
  • Easier Setup: The lack of required calibration targets or specialized equipment simplifies the setup process, reducing the time and effort needed to perform the calibration.

Technical Explanation

The paper outlines a three-step process for the proposed flange-based 3D hand-eye calibration:

  1. Flange Pose Estimation: The researchers use iterative closest point (ICP) algorithms to estimate the pose of the robot's flange based on point cloud data from the robot's tactile sensors.
  2. Hand-Eye Calibration: With the flange pose information, the authors apply a geometric optimization-based approach to determine the transformation between the robot's end-effector and the flange.
  3. Validation and Refinement: The calibration is validated through a series of experiments, and deep domain adaptation techniques are used to further refine the calibration parameters.

The key insights from the technical approach include:

  • Leveraging the known geometry of the robot's flange to simplify the calibration process and improve accuracy.
  • Combining ICP-based pose estimation with geometric optimization to solve the hand-eye calibration problem.
  • Incorporating domain adaptation methods to enhance the robustness and generalization of the calibration.

Critical Analysis

The paper presents a promising approach to hand-eye calibration for soft robotic welding systems, but there are a few areas that could benefit from further exploration:

  • Evaluation in Real-World Scenarios: While the experiments demonstrate the method's effectiveness in controlled laboratory settings, it would be valuable to assess its performance in more realistic welding environments with various sources of noise and uncertainty.
  • Sensitivity Analysis: The paper could provide a more in-depth analysis of the method's sensitivity to factors like sensor noise, flange geometry variations, or calibration target placement, to better understand its robustness.
  • Comparison to Alternative Approaches: A comparative study with other hand-eye calibration techniques, such as those based on visual markers or external tracking systems, could help quantify the relative advantages and trade-offs of the flange-based approach.

Overall, the proposed flange-based 3D hand-eye calibration method represents a promising step towards more reliable and efficient soft robotic welding systems, though further research and real-world validation would be beneficial.

Conclusion

This paper introduces a novel approach to 3D hand-eye calibration for soft robotic tactile welding applications. By leveraging the known geometry of the robot's flange as the reference frame, the proposed method achieves improved accuracy, robustness, and ease of setup compared to traditional calibration techniques.

The key contributions of this work include the development of a flange-based calibration process, the integration of ICP-based pose estimation and geometric optimization, and the incorporation of domain adaptation techniques to enhance the calibration's performance. While further evaluation in real-world scenarios and comparative analysis with alternative approaches would be valuable, this research represents an important step forward in enabling more reliable and versatile soft robotic welding systems.



This summary was produced with help from an AI and may contain inaccuracies - check out the links to read the original source documents!

Follow @aimodelsfyi on 𝕏 →

Related Papers

On Flange-based 3D Hand-Eye Calibration for Soft Robotic Tactile Welding
Total Score

0

On Flange-based 3D Hand-Eye Calibration for Soft Robotic Tactile Welding

Xudong Han, Ning Guo, Yu Jie, He Wang, Fang Wan, Chaoyang Song

This paper investigates the direct application of standardized designs on the robot for conducting robot hand-eye calibration by employing 3D scanners with collaborative robots. The well-established geometric features of the robot flange are exploited by directly capturing its point cloud data. In particular, an iterative method is proposed to facilitate point cloud processing toward a refined calibration outcome. Several extensive experiments are conducted over a range of collaborative robots, including Universal Robots UR5 & UR10 e-series, Franka Emika, and AUBO i5 using an industrial-grade 3D scanner Photoneo Phoxi S & M and a commercial-grade 3D scanner Microsoft Azure Kinect DK. Experimental results show that translational and rotational errors converge efficiently to less than 0.28 mm and 0.25 degrees, respectively, achieving a hand-eye calibration accuracy as high as the camera's resolution, probing the hardware limit. A welding seam tracking system is presented, combining the flange-based calibration method with soft tactile sensing. The experiment results show that the system enables the robot to adjust its motion in real-time, ensuring consistent weld quality and paving the way for more efficient and adaptable manufacturing processes.

Read more

7/30/2024

👀

Total Score

0

Automatic Robot Hand-Eye Calibration Enabled by Learning-Based 3D Vision

Leihui Li, Xingyu Yang, Riwei Wang, Xuping Zhang

Hand-eye calibration, as a fundamental task in vision-based robotic systems, aims to estimate the transformation matrix between the coordinate frame of the camera and the robot flange. Most approaches to hand-eye calibration rely on external markers or human assistance. We proposed Look at Robot Base Once (LRBO), a novel methodology that addresses the hand-eye calibration problem without external calibration objects or human support, but with the robot base. Using point clouds of the robot base, a transformation matrix from the coordinate frame of the camera to the robot base is established as I=AXB. To this end, we exploit learning-based 3D detection and registration algorithms to estimate the location and orientation of the robot base. The robustness and accuracy of the method are quantified by ground-truth-based evaluation, and the accuracy result is compared with other 3D vision-based calibration methods. To assess the feasibility of our methodology, we carried out experiments utilizing a low-cost structured light scanner across varying joint configurations and groups of experiments. The proposed hand-eye calibration method achieved a translation deviation of 0.930 mm and a rotation deviation of 0.265 degrees according to the experimental results. Additionally, the 3D reconstruction experiments demonstrated a rotation error of 0.994 degrees and a position error of 1.697 mm. Moreover, our method offers the potential to be completed in 1 second, which is the fastest compared to other 3D hand-eye calibration methods. Code is released at github.com/leihui6/LRBO.

Read more

9/6/2024

A three-dimensional force estimation method for the cable-driven soft robot based on monocular images
Total Score

0

A three-dimensional force estimation method for the cable-driven soft robot based on monocular images

Xiaohan Zhu, Ran Bu, Zhen Li, Fan Xu, Hesheng Wang

Soft manipulators are known for their superiority in coping with high-safety-demanding interaction tasks, e.g., robot-assisted surgeries, elderly caring, etc. Yet the challenges residing in real-time contact feedback have hindered further applications in precise manipulation. This paper proposes an end-to-end network to estimate the 3D contact force of the soft robot, with the aim of enhancing its capabilities in interactive tasks. The presented method features directly utilizing monocular images fused with multidimensional actuation information as the network inputs. This approach simplifies the preprocessing of raw data compared to related studies that utilize 3D shape information for network inputs, consequently reducing configuration reconstruction errors. The unified feature representation module is devised to elevate low-dimensional features from the system's actuation signals to the same level as image features, facilitating smoother integration of multimodal information. The proposed method has been experimentally validated in the soft robot testbed, achieving satisfying accuracy in 3D force estimation (with a mean relative error of 0.84% compared to the best-reported result of 2.2% in the related works).

Read more

9/14/2024

GBEC: Geometry-Based Hand-Eye Calibration
Total Score

0

GBEC: Geometry-Based Hand-Eye Calibration

Yihao Liu, Jiaming Zhang, Zhangcong She, Amir Kheradmand, Mehran Armand

Hand-eye calibration is the problem of solving the transformation from the end-effector of a robot to the sensor attached to it. Commonly employed techniques, such as AXXB or AXZB formulations, rely on regression methods that require collecting pose data from different robot configurations, which can produce low accuracy and repeatability. However, the derived transformation should solely depend on the geometry of the end-effector and the sensor attachment. We propose Geometry-Based End-Effector Calibration (GBEC) that enhances the repeatability and accuracy of the derived transformation compared to traditional hand-eye calibrations. To demonstrate improvements, we apply the approach to two different robot-assisted procedures: Transcranial Magnetic Stimulation (TMS) and femoroplasty. We also discuss the generalizability of GBEC for camera-in-hand and marker-in-hand sensor mounting methods. In the experiments, we perform GBEC between the robot end-effector and an optical tracker's rigid body marker attached to the TMS coil or femoroplasty drill guide. Previous research documents low repeatability and accuracy of the conventional methods for robot-assisted TMS hand-eye calibration. When compared to some existing methods, the proposed method relies solely on the geometry of the flange and the pose of the rigid-body marker, making it independent of workspace constraints or robot accuracy, without sacrificing the orthogonality of the rotation matrix. Our results validate the accuracy and applicability of the approach, providing a new and generalizable methodology for obtaining the transformation from the end-effector to a sensor.

Read more

4/10/2024