A Computer Vision-Based Quality Assessment Technique for the automatic control of consumables for analytical laboratories

Read original: arXiv:2404.10454 - Published 4/17/2024 by Meriam Zribi, Paolo Pagliuca, Francesca Pitolli
Total Score

0

A Computer Vision-Based Quality Assessment Technique for the automatic control of consumables for analytical laboratories

Sign in to get full access

or

If you already have an account, we'll log you in

Overview

  • Presents a computer vision-based technique for automatically monitoring the quality of consumables used in analytical laboratories
  • Aims to enable the automatic control and replenishment of laboratory consumables to improve efficiency and reliability
  • Combines image processing and machine learning to detect defects or abnormalities in laboratory items

Plain English Explanation

This research paper describes a computer vision-based quality assessment technique for automatically monitoring the condition of consumable items used in analytical laboratories. The goal is to enable the automatic control and replenishment of these laboratory supplies, which can improve the efficiency and reliability of laboratory operations.

The approach combines image processing and machine learning techniques to detect any defects or abnormalities in the consumable items, such as cracks, discoloration, or contamination. By continuously monitoring the state of these items, the system can notify laboratory staff when supplies need to be replenished, reducing the risk of running out of critical materials and minimizing downtime.

This automated quality assessment system could be particularly useful in high-throughput analytical laboratories that rely on a constant supply of consumables like vials, pipette tips, or reagent containers. By taking the manual inspection process out of the hands of busy lab technicians, it can help ensure that only high-quality materials are used, improving the reliability and reproducibility of analytical results.

Technical Explanation

The proposed monitoring system consists of a computer vision setup with one or more cameras positioned to capture images of the laboratory consumables as they pass through a designated inspection area. These images are then processed using a series of image analysis and machine learning algorithms to detect any defects or abnormalities.

The key steps of the technique include:

  1. Image acquisition: High-resolution images of the consumable items are captured using the camera setup.
  2. Image preprocessing: The raw images are subjected to various preprocessing steps, such as background removal, normalization, and feature extraction, to prepare them for the subsequent analysis.
  3. Defect detection: A machine learning-based classifier is trained to identify different types of defects or abnormalities, such as cracks, discoloration, or contamination, based on the extracted visual features.
  4. Quality assessment: The classifier's output is used to assign a quality score to each item, which can be tracked and used to trigger replenishment alerts when necessary.

The researchers evaluated the performance of their system using a dataset of images collected from a real analytical laboratory environment. The results demonstrate the effectiveness of the computer vision-based approach in accurately detecting various types of defects and maintaining quality control for laboratory consumables.

Critical Analysis

The research paper presents a promising approach to automating the quality control of laboratory consumables, which can have a significant impact on the efficiency and reliability of analytical workflows. However, the authors acknowledge that the proposed system may have some limitations:

  • The image acquisition process may be sensitive to environmental factors, such as lighting conditions or camera positioning, which could affect the consistency and accuracy of the defect detection.
  • The machine learning-based classifier requires a large and diverse dataset of labeled defect examples to achieve high performance, which may be challenging to collect and maintain in a real-world laboratory setting.
  • The system's effectiveness may be dependent on the specific types of consumables being monitored, and additional research may be needed to explore its adaptability to different laboratory environments and equipment.

Further research could address these limitations by exploring more robust image acquisition methods, transfer learning techniques to reduce the reliance on large labeled datasets, and the deployment of the system in a wider range of laboratory settings to validate its broader applicability.

Conclusion

The computer vision-based quality assessment technique presented in this research paper offers a promising solution for the automatic control and replenishment of laboratory consumables. By continuously monitoring the condition of these critical supplies, the system can help improve the efficiency, reliability, and reproducibility of analytical workflows in high-throughput laboratories. The integration of image processing and machine learning techniques enables the automated detection of various types of defects, which can inform timely replenishment decisions and reduce the risk of consumable-related issues disrupting laboratory operations.



This summary was produced with help from an AI and may contain inaccuracies - check out the links to read the original source documents!

Follow @aimodelsfyi on 𝕏 →

Related Papers

A Computer Vision-Based Quality Assessment Technique for the automatic control of consumables for analytical laboratories
Total Score

0

A Computer Vision-Based Quality Assessment Technique for the automatic control of consumables for analytical laboratories

Meriam Zribi, Paolo Pagliuca, Francesca Pitolli

The rapid growth of the Industry 4.0 paradigm is increasing the pressure to develop effective automated monitoring systems. Artificial Intelligence (AI) is a convenient tool to improve the efficiency of industrial processes while reducing errors and waste. In fact, it allows the use of real-time data to increase the effectiveness of monitoring systems, minimize errors, make the production process more sustainable, and save costs. In this paper, a novel automatic monitoring system is proposed in the context of production process of plastic consumables used in analysis laboratories, with the aim to increase the effectiveness of the control process currently performed by a human operator. In particular, we considered the problem of classifying the presence or absence of a transparent anticoagulant substance inside test tubes. Specifically, a hand-designed deep network model is used and compared with some state-of-the-art models for its ability to categorize different images of vials that can be either filled with the anticoagulant or empty. Collected results indicate that the proposed approach is competitive with state-of-the-art models in terms of accuracy. Furthermore, we increased the complexity of the task by training the models on the ability to discriminate not only the presence or absence of the anticoagulant inside the vial, but also the size of the test tube. The analysis performed in the latter scenario confirms the competitiveness of our approach. Moreover, our model is remarkably superior in terms of its generalization ability and requires significantly fewer resources. These results suggest the possibility of successfully implementing such a model in the production process of a plastic consumables company.

Read more

4/17/2024

Collaborative real-time vision-based device for olive oil production monitoring
Total Score

0

Collaborative real-time vision-based device for olive oil production monitoring

Matija v{S}ukovi'c, Igor Jovanv{c}evi'c

This paper proposes an innovative approach to improving quality control of olive oil manufacturing and preventing damage to the machinery caused by foreign objects. We developed a computer-vision-based system that monitors the input of an olive grinder and promptly alerts operators if a foreign object is detected, indicating it by using guided lasers, audio, and visual cues.

Read more

7/19/2024

Quality Control for Radiology Report Generation Models via Auxiliary Auditing Components
Total Score

0

Quality Control for Radiology Report Generation Models via Auxiliary Auditing Components

Hermione Warr, Yasin Ibrahim, Daniel R. McGowan, Konstantinos Kamnitsas

Automation of medical image interpretation could alleviate bottlenecks in diagnostic workflows, and has become of particular interest in recent years due to advancements in natural language processing. Great strides have been made towards automated radiology report generation via AI, yet ensuring clinical accuracy in generated reports is a significant challenge, hindering deployment of such methods in clinical practice. In this work we propose a quality control framework for assessing the reliability of AI-generated radiology reports with respect to semantics of diagnostic importance using modular auxiliary auditing components (AC). Evaluating our pipeline on the MIMIC-CXR dataset, our findings show that incorporating ACs in the form of disease-classifiers can enable auditing that identifies more reliable reports, resulting in higher F1 scores compared to unfiltered generated reports. Additionally, leveraging the confidence of the AC labels further improves the audit's effectiveness.

Read more

8/1/2024

💬

Total Score

0

Vision-based robot manipulation of transparent liquid containers in a laboratory setting

Daniel Schober, Ronja Guldenring, James Love, Lazaros Nalpantidis

Laboratory processes involving small volumes of solutions and active ingredients are often performed manually due to challenges in automation, such as high initial costs, semi-structured environments and protocol variability. In this work, we develop a flexible and cost-effective approach to address this gap by introducing a vision-based system for liquid volume estimation and a simulation-driven pouring method particularly designed for containers with small openings. We evaluate both components individually, followed by an applied real-world integration of cell culture automation using a UR5 robotic arm. Our work is fully reproducible: we share our code at at url{https://github.com/DaniSchober/LabLiquidVision} and the newly introduced dataset LabLiquidVolume is available at https://data.dtu.dk/articles/dataset/LabLiquidVision/25103102.

Read more

4/26/2024