Confocal structured illumination microscopy

Read original: arXiv:2405.15519 - Published 5/27/2024 by Weishuai Zhou, Manhong Yao, Xi Lin, Quan Yu, Junzheng Peng, Jingang Zhong
Total Score

0

🤯

Sign in to get full access

or

If you already have an account, we'll log you in

Overview

  • Confocal microscopy is a widely used optical imaging technique, but it has limitations like low imaging efficiency and phototoxicity.
  • Optical-sectioning structured illumination microscopy (OS-SIM) can address some of the limitations of confocal microscopy, but it still faces challenges in imaging depth and signal-to-noise ratio (SNR).
  • The paper introduces a new technique called confocal structured illumination microscopy (CSIM), which combines the principles of confocal microscopy and OS-SIM to enhance the imaging performance.

Plain English Explanation

Microscopes are essential tools in science and medicine, used to study tiny structures that are invisible to the naked eye. Confocal microscopy is a type of microscope that has become widely used because of its ability to produce high-quality, noise-free images. However, this technique has some drawbacks, such as low efficiency in capturing images and the potential to damage the sample being studied.

Optical-sectioning structured illumination microscopy (OS-SIM) is an alternative approach that can overcome some of the limitations of confocal microscopy, but it still faces challenges in terms of imaging depth and the ratio of signal to noise (SNR) in the images.

The researchers in this study have developed a new technique called confocal structured illumination microscopy (CSIM), which combines the strengths of confocal microscopy and OS-SIM. This allows them to produce images with better SNR and greater imaging depth compared to existing OS-SIM techniques. The key idea is to use a special device called a spatial light modulator (SLM) to create a virtual camera, which helps separate the desired signals from unwanted ones in the final image.

Technical Explanation

The researchers have constructed a theoretical framework for CSIM, which exploits the principle of "dual photography" to reconstruct a dual image from each pixel of the camera. This dual image is equivalent to the image that would be obtained by using the SLM as a virtual camera.

By extracting the conjugate signal (the desired signal) from each dual image and rejecting the non-conjugate signals (unwanted signals), the researchers can reconstruct a confocal image that has superior SNR and greater imaging depth compared to existing OS-SIM techniques.

The optical-sectioning experimental results presented in the paper demonstrate the effectiveness of the CSIM approach. The researchers believe that CSIM has the potential to expand the application scope of OS-SIM, making it a valuable tool for various scientific and medical imaging applications.

Critical Analysis

The researchers have provided a detailed theoretical framework and experimental validation for the CSIM technique, which is a promising advancement in optical imaging. However, the paper does not address some potential limitations or areas for further research.

For example, the implementation of the CSIM system may be complex and require specialized equipment, which could limit its widespread adoption. Additionally, the paper does not discuss the computational complexity of the image reconstruction process or the processing time required, which could be important considerations for real-time applications.

Furthermore, the researchers could have explored the performance of CSIM in imaging more complex or dynamic samples, as well as its compatibility with other advanced imaging techniques, such as deep optics or global search optics. These additional experiments could help validate the broader applicability and versatility of the CSIM approach.

Conclusion

The confocal structured illumination microscopy (CSIM) technique introduced in this paper represents a significant advancement in optical imaging, combining the strengths of confocal microscopy and optical-sectioning structured illumination microscopy (OS-SIM). By exploiting the principle of dual photography, CSIM can reconstruct images with superior signal-to-noise ratio and greater imaging depth, addressing some of the limitations of existing OS-SIM approaches.

The successful experimental validation of CSIM suggests that it has the potential to expand the application scope of OS-SIM, making it a more powerful tool for various scientific and medical imaging applications. As researchers continue to explore and refine this technique, it could lead to further breakthroughs in high-resolution, low-noise optical imaging, benefiting fields ranging from biology and medicine to materials science and beyond.



This summary was produced with help from an AI and may contain inaccuracies - check out the links to read the original source documents!

Follow @aimodelsfyi on 𝕏 →

Related Papers

🤯

Total Score

0

Confocal structured illumination microscopy

Weishuai Zhou, Manhong Yao, Xi Lin, Quan Yu, Junzheng Peng, Jingang Zhong

Confocal microscopy, a critical advancement in optical imaging, is widely applied because of its excellent anti-noise ability. However, it has low imaging efficiency and can cause phototoxicity. Optical-sectioning structured illumination microscopy (OS-SIM) can overcome the limitations of confocal microscopy but still face challenges in imaging depth and signal-to-noise ratio (SNR). We introduce the concept of confocal imaging into OS-SIM and propose confocal structured illumination microscopy (CSIM) to enhance the imaging performance of OS-SIM. CSIM exploits the principle of dual photography to reconstruct a dual image from each pixel of the camera. The reconstructed dual image is equivalent to the image obtained by using the spatial light modulator (SLM) as a virtual camera, enabling the separation of the conjugate and non-conjugate signals recorded by the camera pixel. We can reject the non-conjugate signals by extracting the conjugate signal from each dual image to reconstruct a confocal image when establishing the conjugate relationship between the camera and the SLM. We have constructed the theoretical framework of CSIM. Optical-sectioning experimental results demonstrate that CSIM can reconstruct images with superior SNR and greater imaging depth compared with existing OS-SIM. CSIM is expected to expand the application scope of OS-SIM.

Read more

5/27/2024

MicroSSIM: Improved Structural Similarity for Comparing Microscopy Data
Total Score

0

MicroSSIM: Improved Structural Similarity for Comparing Microscopy Data

Ashesh Ashesh, Joran Deschamps, Florian Jug

Microscopy is routinely used to image biological structures of interest. Due to imaging constraints, acquired images are typically low-SNR and contain noise. Over the last few years, regression-based tasks like unsupervised denoising and splitting have found utility in working with such noisy micrographs. For evaluation, Structural Similarity (SSIM) is one of the most popular measures used in the field. For such tasks, the best evaluation would be when both low-SNR noisy images and corresponding high-SNR clean images are obtained directly from a microscope. However, due to the following three peculiar properties of the microscopy data, we observe that SSIM is not well suited to this data regime: (a) high-SNR micrographs have higher intensity pixels as compared to low SNR micrographs, (b) high-SNR micrographs have higher intensity pixels than found in natural images, images for which SSIM was developed, and (c) a digitally configurable offset is added by the detector present inside the microscope. We show that SSIM components behave unexpectedly when the prediction generated from low-SNR input is compared with the corresponding high-SNR data. We explain this behavior by introducing the phenomenon of saturation, where the value of SSIM components becomes less sensitive to (dis)similarity between the images. We introduce microSSIM, a variant of SSIM, which overcomes the above-discussed issues. We justify the soundness and utility of microSSIM using theoretical and empirical arguments and show the utility of microSSIM on two tasks: unsupervised denoising and joint image splitting with unsupervised denoising. Since our formulation can be applied to a broad family of SSIM-based measures, we also introduce MicroMS3IM, a microscopy-specific variation of MS-SSIM. The source code and python package is available at https://github.com/juglab/MicroSSIM.

Read more

8/19/2024

🔮

Total Score

0

Sub-Rayleigh Ghost Imaging via Structured Speckle Illumination

Liming Li

The structured illumination is adopted widely in the super-resolution microscopy imaging. Here, we studied the ghost imaging scheme with sinusoidal structured speckle illumination, whose spatial resolution can surpass the Rayleigh-resolution limit by a factor of 2. In addition, ghost image with a higher spatial resolution can be realized by a pseudo-modulation structured illumination, whose modulation frequency breaks the upper limit of imaging system. Finally, our research verifies that the structural speckle illumination, a free-standing sub-Rayleigh technology, can be grafted with a variety of sub-Rayleigh ghost imaging schemes to further improve the spatial resolution of ghost image, such as the pseudo-inverse ghost imaging.

Read more

8/12/2024

The Quest for Early Detection of Retinal Disease: 3D CycleGAN-based Translation of Optical Coherence Tomography into Confocal Microscopy
Total Score

0

The Quest for Early Detection of Retinal Disease: 3D CycleGAN-based Translation of Optical Coherence Tomography into Confocal Microscopy

Xin Tian, Nantheera Anantrasirichai, Lindsay Nicholson, Alin Achim

Optical coherence tomography (OCT) and confocal microscopy are pivotal in retinal imaging, offering distinct advantages and limitations. In vivo OCT offers rapid, non-invasive imaging but can suffer from clarity issues and motion artifacts, while ex vivo confocal microscopy, providing high-resolution, cellular-detailed color images, is invasive and raises ethical concerns. To bridge the benefits of both modalities, we propose a novel framework based on unsupervised 3D CycleGAN for translating unpaired in vivo OCT to ex vivo confocal microscopy images. This marks the first attempt to exploit the inherent 3D information of OCT and translate it into the rich, detailed color domain of confocal microscopy. We also introduce a unique dataset, OCT2Confocal, comprising mouse OCT and confocal retinal images, facilitating the development of and establishing a benchmark for cross-modal image translation research. Our model has been evaluated both quantitatively and qualitatively, achieving Fr'echet Inception Distance (FID) scores of 0.766 and Kernel Inception Distance (KID) scores as low as 0.153, and leading subjective Mean Opinion Scores (MOS). Our model demonstrated superior image fidelity and quality with limited data over existing methods. Our approach effectively synthesizes color information from 3D confocal images, closely approximating target outcomes and suggesting enhanced potential for diagnostic and monitoring applications in ophthalmology.

Read more

8/9/2024