Controller design and experimental evaluation of a motorised assistance for a patient transfer floor lift

Read original: arXiv:2205.15201 - Published 5/24/2024 by Donatien Callon, Ian Lalonde, Mathieu Nadeau, Alexandre Girard
Total Score

0

🔄

Sign in to get full access

or

If you already have an account, we'll log you in

Overview

  • Patient transfer is a critical task that exposes caregivers to injury risks.
  • Existing transfer devices, such as floor lifts, have limitations in maneuverability and caregiver effort.
  • This paper presents a new motorized floor lift with a single central motorized wheel and an instrumented handle.
  • The system uses admittance controllers to improve maneuverability, reduce caregiver effort, and ensure patient security and comfort.

Plain English Explanation

Moving patients from one place to another is an essential but challenging task for healthcare providers. It can put caregivers at risk of musculoskeletal injuries, as the heavy lifting and maneuvering required can be physically demanding. While devices like floor lifts have helped, they still have problems. They can be difficult to steer and push, requiring a lot of effort from the caregiver.

The researchers in this study developed a new type of motorized floor lift to address these issues. Their device has a single, centrally located motorized wheel and a special handle that provides information to the control system. The controllers they designed use this information to improve the lift's maneuverability, reduce the amount of force the caregiver needs to apply, and ensure the patient is transported safely and comfortably.

Technical Explanation

The researchers created a prototype motorized floor lift with a single, centrally mounted motorized wheel. The lift is equipped with an instrumented handle that provides information to the control system. The researchers developed two types of admittance controllers for this system:

  1. A linear admittance law controller
  2. A non-linear admittance law controller with variable damping

These controllers are designed to:

  1. Enhance the maneuverability of the lift
  2. Decrease the amount of effort required from the caregiver to push the lift
  3. Maintain the patient's security and comfort during transfer

The researchers conducted tests with seven participants to evaluate the performance of the assistance system and the two controller designs. The results showed that:

  1. The motorized assistance with the variable damping controller improved maneuverability by 28% compared to a standard unassisted floor lift.
  2. The variable damping controller reduced the amount of effort required to push the lift by 66%.
  3. Both controller designs provided the same level of patient comfort as the standard unassisted floor lift.

Critical Analysis

The researchers acknowledge that their study had a relatively small sample size and was conducted in a controlled laboratory environment. Additional testing would be needed to validate the performance of the system in real-world healthcare settings. There may also be concerns about the reliability and maintainability of the motorized components over long-term use.

One area for further research could be exploring ways to adaptively tune the controller parameters to account for variations in patient size, weight, and mobility. Integrating adaptive remote center of motion control could also help improve safety and comfort during patient transfers.

Additionally, the researchers do not discuss the potential cost implications of implementing this motorized floor lift system compared to standard manual or powered floor lifts. This would be an important consideration for healthcare facilities when evaluating new patient transfer technologies.

Conclusion

This research presents a promising new approach to patient transfer devices that aims to improve caregiver safety and patient comfort. The motorized floor lift with advanced admittance controllers demonstrates significant enhancements in maneuverability and reductions in caregiver effort compared to standard floor lifts. While further research is needed to validate the system in real-world settings, this work highlights the potential for innovative robotic technologies to transform critical healthcare tasks and improve outcomes for both caregivers and patients.



This summary was produced with help from an AI and may contain inaccuracies - check out the links to read the original source documents!

Follow @aimodelsfyi on 𝕏 →

Related Papers

🔄

Total Score

0

Controller design and experimental evaluation of a motorised assistance for a patient transfer floor lift

Donatien Callon, Ian Lalonde, Mathieu Nadeau, Alexandre Girard

Patient transfer is a challenging, critical task because it exposes caregivers to injury risks. Available transfer devices, like floor lifts, lead to improvements but are far from perfect. They do not eliminate the caregivers risk of musculoskeletal disorders, and they can be burdensome to use due to their poor maneuverability. This paper presents a new motorized floor lift with a single central motorized wheel connected to an instrumented handle. Admittance controllers are designed to 1) improve the device maneuverability, 2) reduce the required caregiver effort, and 3) ensure the security and comfort of patients. Two controller designs, one with a linear admittance law and a non-linear admittance law with variable damping, were developed and implemented on a prototype. Tests were performed on seven participants to evaluate the performance of the assistance system and the controllers. The experimental results show that 1) the motorized assistance with the variable damping controller improves maneuverability by 28%, 2) reduces the amount of effort required to push the lift by 66% and 3) provides the same level of patient comfort compared to a standard unassisted floor lift.

Read more

5/24/2024

🤖

Total Score

0

A Dual-Motor Actuator for Ceiling Robots with High Force and High Speed Capabilities

Ian Lalonde, Jeff Denis, Mathieu Lamy, Alexandre Girard

Patient transfer devices allow to move patients passively in hospitals and care centers. Instead of hoisting the patient, it would be beneficial in some cases to assist their movement, enabling them to move by themselves. However, patient assistance requires devices capable of precisely controlling output forces at significantly higher speeds than those used for patient transfers alone, and a single motor solution would be over-sized and show poor efficiency to do both functions. This paper presents a dual-motor actuator and control schemes adapted for a patient mobility equipment that can be used to transfer patients, assist patient in their movement, and help prevent falls. The prototype is shown to be able to lift patients weighing up to 318 kg, to assist a patient with a desired force of up to 100 kg with a precision of 7.8%. Also, a smart control scheme to manage falls is shown to be able to stop a patient who is falling by applying a desired deceleration.

Read more

5/9/2024

Design and Control of a Low-cost Non-backdrivable End-effector Upper Limb Rehabilitation Device
Total Score

0

Design and Control of a Low-cost Non-backdrivable End-effector Upper Limb Rehabilitation Device

Fulan Li, Yunfei Guo, Wenda Xu, Weide Zhang, Fangyun Zhao, Baiyu Wang, Huaguang Du, Chengkun Zhang

This paper presents the development of an upper limb end-effector based rehabilitation device for stroke patients, offering assistance or resistance along any 2-dimensional trajectory during physical therapy. It employs a non-backdrivable ball-screw-driven mechanism for enhanced control accuracy. The control system features three novel algorithms: First, the Implicit Euler velocity control algorithm (IEVC) highlighted for its state-of-the-art accuracy, stability, efficiency and generalizability in motion restriction control. Second, an Admittance Virtual Dynamics simulation algorithm that achieves a smooth and natural human interaction with the non-backdrivable end-effector. Third, a generalized impedance force calculation algorithm allowing efficient impedance control on any trajectory or area boundary. Experimental validation demonstrated the system's effectiveness in accurate end-effector position control across various trajectories and configurations. The proposed upper limb end-effector-based rehabilitation device, with its high performance and adaptability, holds significant promise for extensive clinical application, potentially improving rehabilitation outcomes for stroke patients.

Read more

6/24/2024

Adaptive Control in Assistive Application -- A Study Evaluating Shared Control by Users with Limited Upper Limb Mobility
Total Score

0

Adaptive Control in Assistive Application -- A Study Evaluating Shared Control by Users with Limited Upper Limb Mobility

Felix Ferdinand Goldau, Max Pascher, Annalies Baumeister, Patrizia Tolle, Jens Gerken, Udo Frese

Shared control in assistive robotics blends human autonomy with computer assistance, thus simplifying complex tasks for individuals with physical impairments. This study assesses an adaptive Degrees of Freedom control method specifically tailored for individuals with upper limb impairments. It employs a between-subjects analysis with 24 participants, conducting 81 trials across three distinct input devices in a realistic everyday-task setting. Given the diverse capabilities of the vulnerable target demographic and the known challenges in statistical comparisons due to individual differences, the study focuses primarily on subjective qualitative data. The results reveal consistently high success rates in trial completions, irrespective of the input device used. Participants appreciated their involvement in the research process, displayed a positive outlook, and quick adaptability to the control system. Notably, each participant effectively managed the given task within a short time frame.

Read more

6/11/2024