  • Photoacoustic tomography (PAT) is a non-invasive imaging technique that can capture cross-sectional images of biological tissues.
  • However, PAT fails to map the spatial variation of speed-of-sound (SOS) within tissues.
  • SOS is closely related to the density and elastic modulus of tissues, so mapping SOS distribution can provide complementary information to PAT.
  • An accurate SOS map can also help correct PAT image degradation caused by acoustic heterogeneities.
  • This paper proposes a novel approach to reconstruct SOS distribution using only the PAT imaging modality.

Plain English Explanation

Photoacoustic tomography (PAT) is a medical imaging technique that allows doctors to take cross-sectional pictures of the inside of the body without making any incisions. However, PAT has a limitation - it can't accurately map how the speed of sound varies within different tissues.

The speed of sound is closely linked to the density and stiffness of tissues. Being able to map the speed of sound distribution could provide valuable additional information to complement the PAT images. It could also help fix issues in the PAT images caused by variations in how sound travels through different tissues.

This paper introduces a new way to reconstruct the speed of sound map using only the PAT imaging technique. The researchers use special light-absorbing targets called "photoacoustic reversal beacons" that are placed around the tissue being imaged. When these beacons are illuminated, they generate soundwaves that travel through the tissue from different directions. By analyzing how these soundwaves propagate, the researchers can calculate the speed of sound at different locations inside the tissue.

The researchers demonstrate through simulations, phantom experiments, and tests on real biological tissues that this approach can accurately reconstruct the speed of sound distribution. They also show how using the reconstructed speed of sound map can significantly improve the quality of the original PAT images.

Technical Explanation

The key innovation in this paper is the use of photoacoustic reversal beacons (PRBs) - small light-absorbing targets with strong photoacoustic contrast. The researchers position multiple PRBs around the target tissue and excite them one-by-one. The photoacoustic waves generated by each PRB propagate through the tissue from different directions, effectively sampling the internal speed-of-sound (SOS) distribution.

The researchers then formulate a linear inverse model for pixel-wise SOS reconstruction and solve it using an iterative optimization technique. This allows them to reconstruct the full SOS map of the target tissue.

Through simulations, phantom experiments, and ex vivo biological tissue tests, the researchers demonstrate the feasibility and accuracy of their proposed SOS reconstruction approach. They further show how leveraging the obtained SOS map can significantly enhance the PAT image reconstruction by correcting for acoustic heterogeneities.

Critical Analysis

The paper presents a promising approach to overcome a key limitation of PAT by reconstructing the SOS distribution within tissues. The use of PRBs is a clever way to sample the internal SOS without requiring additional imaging modalities.

However, the paper does not discuss the potential challenges in practically implementing this technique. Placing multiple PRBs around the target tissue may be challenging in certain clinical scenarios. The impact of PRB placement, size, and number on the SOS reconstruction accuracy is also not thoroughly explored.

Additionally, while the experiments demonstrate the feasibility of the approach, more comprehensive validation on a diverse set of tissue types and in vivo scenarios would be needed to assess its broader applicability and robustness.

Conclusion

This paper introduces a novel PAT-based method to reconstruct the speed-of-sound distribution within biological tissues. By utilizing photoacoustic reversal beacons, the technique can sample the internal SOS from multiple directions and accurately reconstruct the SOS map.

The obtained SOS information can then be leveraged to significantly enhance the quality of PAT images by correcting for acoustic heterogeneities. This represents an important step towards overcoming a key limitation of PAT and providing complementary information to improve diagnostic capabilities.

Further research is needed to address practical implementation challenges and expand the validation of this approach. However, this work demonstrates the potential of PAT-based SOS reconstruction to advance photoacoustic imaging and its clinical applications.



This summary was produced with help from an AI and may contain inaccuracies - check out the links to read the original source documents!

Follow @aimodelsfyi on 𝕏 →

Related Papers

🐍

Total Score

0

Cross-sectional imaging of speed-of-sound distribution using photoacoustic reversal beacons

Yang Wang, Danni Wang, Liting Zhong, Yi Zhou, Qing Wang, Wufan Chen, Li Qi

Photoacoustic tomography (PAT) enables non-invasive cross-sectional imaging of biological tissues, but it fails to map the spatial variation of speed-of-sound (SOS) within tissues. While SOS is intimately linked to density and elastic modulus of tissues, the imaging of SOS distri-bution serves as a complementary imaging modality to PAT. Moreover, an accurate SOS map can be leveraged to correct for PAT image degradation arising from acoustic heterogene-ities. Herein, we propose a novel approach for SOS reconstruction using only PAT imaging modality. Our method is based on photoacoustic reversal beacons (PRBs), which are small light-absorbing targets with strong photoacoustic contrast. We excite and scan a number of PRBs positioned at the periphery of the target, and the generated photoacoustic waves prop-agate through the target from various directions, thereby achieve spatial sampling of the internal SOS. We formulate a linear inverse model for pixel-wise SOS reconstruction and solve it with iterative optimization technique. We validate the feasibility of the proposed method through simulations, phantoms, and ex vivo biological tissue tests. Experimental results demonstrate that our approach can achieve accurate reconstruction of SOS distribu-tion. Leveraging the obtained SOS map, we further demonstrate significantly enhanced PAT image reconstruction with acoustic correction.

Read more

8/27/2024

Spiral Scanning and Self-Supervised Image Reconstruction Enable Ultra-Sparse Sampling Multispectral Photoacoustic Tomography
Total Score

0

Spiral Scanning and Self-Supervised Image Reconstruction Enable Ultra-Sparse Sampling Multispectral Photoacoustic Tomography

Yutian Zhong, Xiaoming Zhang, Zongxin Mo, Shuangyang Zhang, Wufan Chen, Li Qi

Multispectral photoacoustic tomography (PAT) is an imaging modality that utilizes the photoacoustic effect to achieve non-invasive and high-contrast imaging of internal tissues. However, the hardware cost and computational demand of a multispectral PAT system consisting of up to thousands of detectors are huge. To address this challenge, we propose an ultra-sparse spiral sampling strategy for multispectral PAT, which we named U3S-PAT. Our strategy employs a sparse ring-shaped transducer that, when switching excitation wavelengths, simultaneously rotates and translates. This creates a spiral scanning pattern with multispectral angle-interlaced sampling. To solve the highly ill-conditioned image reconstruction problem, we propose a self-supervised learning method that is able to introduce structural information shared during spiral scanning. We simulate the proposed U3S-PAT method on a commercial PAT system and conduct in vivo animal experiments to verify its performance. The results show that even with a sparse sampling rate as low as 1/30, our U3S-PAT strategy achieves similar reconstruction and spectral unmixing accuracy as non-spiral dense sampling. Given its ability to dramatically reduce the time required for three-dimensional multispectral scanning, our U3S-PAT strategy has the potential to perform volumetric molecular imaging of dynamic biological activities.

Read more

4/11/2024

Neural Fields for Adaptive Photoacoustic Computed Tomography
Total Score

0

New!Neural Fields for Adaptive Photoacoustic Computed Tomography

Tianao Li, Manxiu Cui, Cheng Ma, Emma Alexander

Photoacoustic computed tomography (PACT) is a non-invasive imaging modality with wide medical applications. Conventional PACT image reconstruction algorithms suffer from wavefront distortion caused by the heterogeneous speed of sound (SOS) in tissue, which leads to image degradation. Accounting for these effects improves image quality, but measuring the SOS distribution is experimentally expensive. An alternative approach is to perform joint reconstruction of the initial pressure image and SOS using only the PA signals. Existing joint reconstruction methods come with limitations: high computational cost, inability to directly recover SOS, and reliance on inaccurate simplifying assumptions. Implicit neural representation, or neural fields, is an emerging technique in computer vision to learn an efficient and continuous representation of physical fields with a coordinate-based neural network. In this work, we introduce NF-APACT, an efficient self-supervised framework utilizing neural fields to estimate the SOS in service of an accurate and robust multi-channel deconvolution. Our method removes SOS aberrations an order of magnitude faster and more accurately than existing methods. We demonstrate the success of our method on a novel numerical phantom as well as an experimentally collected phantom and in vivo data. Our code and numerical phantom are available at https://github.com/Lukeli0425/NF-APACT.

Read more

9/18/2024

Sparse-view Signal-domain Photoacoustic Tomography Reconstruction Method Based on Neural Representation
Total Score

0

Sparse-view Signal-domain Photoacoustic Tomography Reconstruction Method Based on Neural Representation

Bowei Yao, Yi Zeng, Haizhao Dai, Qing Wu, Youshen Xiao, Fei Gao, Yuyao Zhang, Jingyi Yu, Xiran Cai

Photoacoustic tomography is a hybrid biomedical technology, which combines the advantages of acoustic and optical imaging. However, for the conventional image reconstruction method, the image quality is affected obviously by artifacts under the condition of sparse sampling. in this paper, a novel model-based sparse reconstruction method via implicit neural representation was proposed for improving the image quality reconstructed from sparse data. Specially, the initial acoustic pressure distribution was modeled as a continuous function of spatial coordinates, and parameterized by a multi-layer perceptron. The weights of multi-layer perceptron were determined by training the network in self-supervised manner. And the total variation regularization term was used to offer the prior knowledge. We compared our result with some ablation studies, and the results show that out method outperforms existing methods on simulation and experimental data. Under the sparse sampling condition, our method can suppress the artifacts and avoid the ill-posed problem effectively, which reconstruct images with higher signal-to-noise ratio and contrast-to-noise ratio than traditional methods. The high-quality results for sparse data make the proposed method hold the potential for further decreasing the hardware cost of photoacoustic tomography system.

Read more

6/26/2024