Inverse Problem Approach to Aberration Correction for in vivo Transcranial Imaging Based on a Sparse Representation of Contrast-enhanced Ultrasound Data

Read original: arXiv:2401.10389 - Published 5/15/2024 by Paul Xing, Antoine Malescot, Eric Martineau, Ravi Rungta, Jean Provost
Total Score

0

Inverse Problem Approach to Aberration Correction for in vivo Transcranial Imaging Based on a Sparse Representation of Contrast-enhanced Ultrasound Data

Sign in to get full access

or

If you already have an account, we'll log you in

Overview

  • This paper presents an inverse problem approach for transcranial imaging using contrast-enhanced ultrasound data.
  • The method relies on a sparse representation of the contrast-enhanced ultrasound data to improve in vivo brain imaging through the skull.
  • The approach aims to overcome the challenges of transcranial imaging, such as the distortion and attenuation of ultrasound signals caused by the skull.

Plain English Explanation

The human skull can be a significant barrier for accurately imaging the brain using ultrasound technology. This paper describes a new method to overcome these challenges and improve the quality of brain imaging through the skull.

The key idea is to use a special type of ultrasound imaging called contrast-enhanced ultrasound. This technique involves injecting a harmless substance into the bloodstream that makes certain tissues in the body, like the brain, more visible on the ultrasound images.

The researchers then take these contrast-enhanced ultrasound images and represent them in a sparse, or compact, way. This sparse representation allows them to better model the way the ultrasound signals are distorted and attenuated as they pass through the skull.

By using this sparse representation, the researchers can then solve an "inverse problem" to reconstruct a high-quality image of the brain, even though the original ultrasound data was distorted by the skull. This inverse problem approach helps overcome the limitations of traditional ultrasound brain imaging techniques.

Overall, this method provides a promising way to improve the quality and accuracy of brain imaging using ultrasound, which could have important applications in medical diagnosis and treatment.

Technical Explanation

The paper proposes an inverse problem approach to transcranial imaging using contrast-enhanced ultrasound (CEUS) data. The key elements are:

  1. Contrast-Enhanced Ultrasound (CEUS): The researchers use CEUS, where a contrast agent is injected into the bloodstream to enhance the visibility of certain tissues, such as the brain vasculature, on the ultrasound images.

  2. Sparse Representation: The CEUS data is represented in a sparse way, meaning it is encoded using a compact set of coefficients. This sparse representation helps model the distortion and attenuation of the ultrasound signals as they pass through the skull.

  3. Inverse Problem: An inverse problem is solved to reconstruct a high-quality image of the brain from the distorted CEUS data. This inverse problem approach overcomes the limitations of traditional ultrasound brain imaging techniques.

The researchers demonstrate the effectiveness of their method using both simulated and experimental data, showing improvements in image quality and resolution compared to traditional approaches. This work builds on prior research in power Doppler imaging and optoacoustic tomography to advance the field of transcranial brain imaging.

Critical Analysis

One potential limitation of this approach is that it relies on the injection of a contrast agent, which may not be suitable or desirable for all clinical applications. Additionally, the sparse representation and inverse problem solving steps add computational complexity to the imaging process, which could impact the real-time performance of the system.

Further research is needed to explore the robustness of this method to variations in skull thickness and density, as well as to validate its performance in a wider range of in vivo scenarios. Comparisons to other transcranial imaging techniques, such as coordinate-based neural representations or spiral scanning self-supervised reconstruction, would also help to contextualize the strengths and limitations of this approach.

Conclusion

This paper presents a novel inverse problem-based approach for transcranial imaging using contrast-enhanced ultrasound data. By leveraging a sparse representation of the CEUS data, the researchers are able to overcome the distortions caused by the skull and reconstruct high-quality images of the brain.

This work has the potential to significantly improve the utility of ultrasound for in vivo brain imaging, with applications in medical diagnosis, neurosurgical planning, and neurological research. Further development and validation of this technique could lead to more accessible and affordable brain imaging solutions, with important implications for healthcare and scientific discovery.



This summary was produced with help from an AI and may contain inaccuracies - check out the links to read the original source documents!

Follow @aimodelsfyi on 𝕏 →

Related Papers

Inverse Problem Approach to Aberration Correction for in vivo Transcranial Imaging Based on a Sparse Representation of Contrast-enhanced Ultrasound Data
Total Score

0

Inverse Problem Approach to Aberration Correction for in vivo Transcranial Imaging Based on a Sparse Representation of Contrast-enhanced Ultrasound Data

Paul Xing, Antoine Malescot, Eric Martineau, Ravi Rungta, Jean Provost

Transcranial ultrasound imaging is currently limited by attenuation and aberration induced by the skull. First used in contrast-enhanced ultrasound (CEUS), highly echoic microbubbles allowed for the development of novel imaging modalities such as ultrasound localization microscopy (ULM). Herein, we develop an inverse problem approach to aberration correction (IPAC) that leverages the sparsity of microbubble signals. We propose to use the textit{a priori} knowledge of the medium based upon microbubble localization and wave propagation to build a forward model to link the measured signals directly to the aberration function. A standard least-squares inversion is then used to retrieve the aberration function. We first validated IPAC on simulated data of a vascular network using plane wave as well as divergent wave emissions. We then evaluated the reproducibility of IPAC textit{in vivo} in 5 mouse brains. We showed that aberration correction improved the contrast of CEUS images by 4.6 dB. For ULM images, IPAC yielded sharper vessels, reduced vessel duplications, and improved the resolution from 21.1 $mu$m to 18.3 $mu$m. Aberration correction also improved hemodynamic quantification for velocity magnitude and flow direction.

Read more

5/15/2024

PHOCUS: Physics-Based Deconvolution for Ultrasound Resolution Enhancement
Total Score

0

PHOCUS: Physics-Based Deconvolution for Ultrasound Resolution Enhancement

Felix Duelmer, Walter Simson, Mohammad Farid Azampour, Magdalena Wysocki, Angelos Karlas, Nassir Navab

Ultrasound is widely used in medical diagnostics allowing for accessible and powerful imaging but suffers from resolution limitations due to diffraction and the finite aperture of the imaging system, which restricts diagnostic use. The impulse function of an ultrasound imaging system is called the point spread function (PSF), which is convolved with the spatial distribution of reflectors in the image formation process. Recovering high-resolution reflector distributions by removing image distortions induced by the convolution process improves image clarity and detail. Conventionally, deconvolution techniques attempt to rectify the imaging system's dependent PSF, working directly on the radio-frequency (RF) data. However, RF data is often not readily accessible. Therefore, we introduce a physics-based deconvolution process using a modeled PSF, working directly on the more commonly available B-mode images. By leveraging Implicit Neural Representations (INRs), we learn a continuous mapping from spatial locations to their respective echogenicity values, effectively compensating for the discretized image space. Our contribution consists of a novel methodology for retrieving a continuous echogenicity map directly from a B-mode image through a differentiable physics-based rendering pipeline for ultrasound resolution enhancement. We qualitatively and quantitatively evaluate our approach on synthetic data, demonstrating improvements over traditional methods in metrics such as PSNR and SSIM. Furthermore, we show qualitative enhancements on an ultrasound phantom and an in-vivo acquisition of a carotid artery.

Read more

8/9/2024

🤷

Total Score

0

High-resolution Power Doppler Using Null Subtraction Imaging

Zhengchang Kou, Matthew Lowerison, Qi You, Yike Wang, Pengfei Song, Michael L. Oelze

To improve the spatial resolution of power Doppler (PD) imaging, we explored null subtraction imaging (NSI) as an alternative beamforming technique to delay-and-sum (DAS). NSI is a nonlinear beamforming approach that uses three different apodizations on receive and incoherently sums the beamformed envelopes. NSI uses a null in the beam pattern to improve the lateral resolution, which we apply here for improving PD spatial resolution both with and without contrast microbubbles. In this study, we used NSI with three types of singular value decomposition (SVD)-based clutter filters and noise equalization to generate high-resolution PD images. An element sensitivity correction scheme was also proposed as a crucial component of NSI-based PD imaging. First, a microbubble trace experiment was performed to evaluate the resolution improvement of NSI-based PD over traditional DAS-based PD. Then, both contrast-enhanced and contrast free ultrasound PD images were generated from the scan of a rat brain. The cross-sectional profile of the microbubble traces and microvessels were plotted. FWHM was also estimated to provide a quantitative metric. Furthermore, iso-frequency curves were calculated to provide a resolution evaluation metric over the global field of view. Up to six-fold resolution improvement was demonstrated by the FWHM estimate and four-fold resolution improvement was demonstrated by the iso-frequency curve from the NSI-based PD microvessel images compared to microvessel images generated by traditional DAS-based beamforming. A resolvability of 39 um was measured from the NSI-based PD microvessel image. The computational cost of NSI-based PD was only increased by 40 percent over the DAS-based PD.

Read more

4/4/2024

💬

Total Score

0

A Method for Accurate Spatial Focusing Simulation via Numerical Integration and its Application in Optoacoustic Tomography

Maximilian Bader, Philipp Haim, Lukas Imanuel Scheel-Platz, Angelos Karlas, Hedwig Irl, Vasilis Ntziachristos, Dominik Justel

The spatial sensitivity of an ultrasound transducer, which strongly influences its suitability for different applications, depends on the shape of the transducer surface. Accurate simulation of these spatial effects is important for transducer characterization and design, and for system response modelling in imaging applications. In optoacoustic imaging, broadband transducers are used to capitalize on the rich frequency content of the signals, but their usage makes highly accurate simulations with general wave equation solvers prohibitively memory- and time-intensive. Therefore, specialized tools for simulating the isolated spatial focusing properties described by the spatial impulse response (SIR) have been developed. However, the challenging numerics of the SIR and the necessity to convolve the SIR with the wave shape generated by the optoacoustic absorber to simulate the system response lead to numerical inaccuracies of SIR-based methods. In addition, the approximation error of these methods cannot be controlled a priori. To circumvent the problems associated with the explicit calculation of SIR, we propose directly computing the convolution of the required wave shape with the SIR, which we call the spatial pulse response (SPR). We demonstrate that by utilizing an h-adaptive cubature algorithm, SPR can be computed with significantly higher accuracy than an SIR-based reference method, and the approximation error can be controlled with a tolerance parameter. In addition, the integration of accurate SPR simulations into model-based optoacoustic image reconstruction is shown to improve image contrast and reduce noise artifacts. Precise system characterization and simulation leads to improved imaging performance, ultimately increasing the value of optoacoustic imaging systems for clinical applications.

Read more

9/17/2024