Deep kernel representations of latent space features for low-dose PET-MR imaging robust to variable dose reduction

Read original: arXiv:2409.06198 - Published 9/11/2024 by Cameron Dennis Pain, Yasmeen George, Alex Fornito, Gary Egan, Zhaolin Chen
Total Score

0

Deep kernel representations of latent space features for low-dose PET-MR imaging robust to variable dose reduction

Sign in to get full access

or

If you already have an account, we'll log you in

Overview

  • This paper proposes a deep learning-based approach for low-dose PET-MR imaging that is robust to variable dose reduction.
  • The key ideas are to learn deep kernel representations of latent space features and use them for robust PET-MR reconstruction.
  • The method is evaluated on various low-dose PET-MR datasets and demonstrates improved performance compared to existing approaches.

Plain English Explanation

In medical imaging, PET-MR is a technique that combines positron emission tomography (PET) and magnetic resonance imaging (MRI) to provide detailed information about the body. However, reducing the radiation dose in PET scans can result in noisy and low-quality images.

This paper presents a new deep learning-based method to address this issue. The key idea is to learn deep kernel representations of the latent features in the low-dose PET-MR images. These learned representations are then used to reconstruct high-quality PET-MR images that are robust to varying levels of dose reduction.

The method works by first training a deep neural network to extract meaningful latent features from the low-dose PET-MR data. It then learns a set of deep kernel functions that can effectively capture the relationships between these latent features. Finally, it uses the learned deep kernels to reconstruct the final PET-MR images, which are of higher quality and less affected by dose reduction.

The researchers evaluate their approach on several low-dose PET-MR datasets and show that it outperforms existing methods in terms of image quality and robustness to dose variations.

Technical Explanation

The paper proposes a novel deep learning-based approach for low-dose PET-MR imaging that is robust to variable dose reduction. The key technical contributions are:

  1. Learning deep kernel representations of latent space features: The method first trains a deep neural network to extract meaningful latent features from the low-dose PET-MR data. It then learns a set of deep kernel functions that can effectively capture the relationships between these latent features.

  2. Robust PET-MR reconstruction using deep kernels: The learned deep kernels are used to reconstruct the final PET-MR images, which are of higher quality and less affected by dose reduction. This is achieved by leveraging the rich representational power of the deep kernels to model the complex dependencies in the low-dose data.

  3. Evaluation on low-dose PET-MR datasets: The researchers evaluate their approach on several low-dose PET-MR datasets and show that it outperforms existing methods in terms of image quality and robustness to dose variations.

The key technical insights from the paper are:

  • Importance of latent feature representations: The paper demonstrates the importance of learning effective latent feature representations for low-dose PET-MR imaging, as these features capture the essential characteristics of the data.
  • Power of deep kernels: The deep kernel functions are shown to be a powerful tool for modeling the complex relationships in the low-dose PET-MR data, leading to improved reconstruction performance.
  • Robustness to dose variations: The proposed approach is able to maintain high image quality across a range of dose levels, making it a valuable tool for practical PET-MR imaging applications.

Critical Analysis

The paper presents a promising approach for addressing the challenges of low-dose PET-MR imaging, but there are a few potential caveats and areas for further research:

  1. Generalization to diverse patient populations: The evaluation in the paper is based on a limited set of datasets, and it would be important to assess the method's performance on a wider range of patient cohorts, including those with different medical conditions or anatomical characteristics.

  2. Computational efficiency: While the deep kernel representations are powerful, they may also be computationally intensive, which could limit the practical deployment of the method in real-time clinical settings. Exploring ways to optimize the computational complexity would be an important future direction.

  3. Interpretability and explainability: As with many deep learning approaches, the inner workings of the proposed method may be difficult to interpret, which could hinder its acceptance in the medical community. Developing more interpretable and explainable variants of the approach could enhance its clinical utility.

  4. Validation in clinical trials: Ultimately, the true test of the method's effectiveness will be through rigorous clinical validation, including large-scale studies and comparison to current standard-of-care practices. This will be an essential step before the method can be widely adopted in clinical settings.

Conclusion

This paper presents a novel deep learning-based approach for low-dose PET-MR imaging that is robust to variable dose reduction. The key technical contributions are the learning of deep kernel representations of latent space features and the use of these kernels for robust PET-MR reconstruction.

The method has been evaluated on various low-dose PET-MR datasets and has demonstrated improved performance compared to existing approaches. However, there are still some potential caveats and areas for further research, such as evaluating the method's generalization to diverse patient populations, optimizing its computational efficiency, and enhancing its interpretability and explainability.

Overall, this work represents an important step forward in addressing the challenges of low-dose PET-MR imaging and has the potential to significantly improve the quality and robustness of medical imaging in clinical settings.



This summary was produced with help from an AI and may contain inaccuracies - check out the links to read the original source documents!

Follow @aimodelsfyi on 𝕏 →

Related Papers

Deep kernel representations of latent space features for low-dose PET-MR imaging robust to variable dose reduction
Total Score

0

Deep kernel representations of latent space features for low-dose PET-MR imaging robust to variable dose reduction

Cameron Dennis Pain, Yasmeen George, Alex Fornito, Gary Egan, Zhaolin Chen

Low-dose positron emission tomography (PET) image reconstruction methods have potential to significantly improve PET as an imaging modality. Deep learning provides a promising means of incorporating prior information into the image reconstruction problem to produce quantitatively accurate images from compromised signal. Deep learning-based methods for low-dose PET are generally poorly conditioned and perform unreliably on images with features not present in the training distribution. We present a method which explicitly models deep latent space features using a robust kernel representation, providing robust performance on previously unseen dose reduction factors. Additional constraints on the information content of deep latent features allow for tuning in-distribution accuracy and generalisability. Tests with out-of-distribution dose reduction factors ranging from $times 10$ to $times 1000$ and with both paired and unpaired MR, demonstrate significantly improved performance relative to conventional deep-learning methods trained using the same data. Code:https://github.com/cameronPain

Read more

9/11/2024

📈

Total Score

0

Diffusion Transformer Model With Compact Prior for Low-dose PET Reconstruction

Bin Huang, Xubiao Liu, Lei Fang, Qiegen Liu, Bingxuan Li

Positron emission tomography (PET) is an advanced medical imaging technique that plays a crucial role in non-invasive clinical diagnosis. However, while reducing radiation exposure through low-dose PET scans is beneficial for patient safety, it often results in insufficient statistical data. This scarcity of data poses significant challenges for accurately reconstructing high-quality images, which are essential for reliable diagnostic outcomes. In this research, we propose a diffusion transformer model (DTM) guided by joint compact prior (JCP) to enhance the reconstruction quality of low-dose PET imaging. In light of current research findings, we present a pioneering PET reconstruction model that integrates diffusion and transformer models for joint optimization. This model combines the powerful distribution mapping abilities of diffusion models with the capacity of transformers to capture long-range dependencies, offering significant advantages for low-dose PET reconstruction. Additionally, the incorporation of the lesion refining block and penalized weighted least squares (PWLS) enhance the recovery capability of lesion regions and preserves detail information, solving blurring problems in lesion areas and texture details of most deep learning frameworks. Experimental results demonstrate the effectiveness of DTM in enhancing image quality and preserving critical clinical information for low-dose PET scans. Our approach not only reduces radiation exposure risks but also provides a more reliable PET imaging tool for early disease detection and patient management.

Read more

7/2/2024

Dose-aware Diffusion Model for 3D Low-dose PET: Multi-institutional Validation with Reader Study and Real Low-dose Data
Total Score

0

Dose-aware Diffusion Model for 3D Low-dose PET: Multi-institutional Validation with Reader Study and Real Low-dose Data

Huidong Xie, Weijie Gan, Bo Zhou, Ming-Kai Chen, Michal Kulon, Annemarie Boustani, Benjamin A. Spencer, Reimund Bayerlein, Wei Ji, Xiongchao Chen, Qiong Liu, Xueqi Guo, Menghua Xia, Yinchi Zhou, Hui Liu, Liang Guo, Hongyu An, Ulugbek S. Kamilov, Hanzhong Wang, Biao Li, Axel Rominger, Kuangyu Shi, Ge Wang, Ramsey D. Badawi, Chi Liu

Reducing scan times, radiation dose, and enhancing image quality, especially for lower-performance scanners, are critical in low-count/low-dose PET imaging. Deep learning (DL) techniques have been investigated for PET image denoising. However, existing models have often resulted in compromised image quality when achieving low-dose PET and have limited generalizability to different image noise-levels, acquisition protocols, and patient populations. Recently, diffusion models have emerged as the new state-of-the-art generative model to generate high-quality samples and have demonstrated strong potential for medical imaging tasks. However, for low-dose PET imaging, existing diffusion models failed to generate consistent 3D reconstructions, unable to generalize across varying noise-levels, often produced visually-appealing but distorted image details, and produced images with biased tracer uptake. Here, we develop DDPET-3D, a dose-aware diffusion model for 3D low-dose PET imaging to address these challenges. Collected from 4 medical centers globally with different scanners and clinical protocols, we extensively evaluated the proposed model using a total of 9,783 18F-FDG studies (1,596 patients) with low-dose/low-count levels ranging from 1% to 50%. With a cross-center, cross-scanner validation, the proposed DDPET-3D demonstrated its potential to generalize to different low-dose levels, different scanners, and different clinical protocols. As confirmed with reader studies performed by nuclear medicine physicians, experienced readers judged the images to be similar to or superior to the full-dose images and previous DL baselines based on qualitative visual impression. The presented results show the potential of achieving low-dose PET while maintaining image quality. Lastly, a group of real low-dose scans was also included for evaluation to demonstrate the clinical potential of DDPET-3D.

Read more

9/5/2024

🖼️

Total Score

0

Two-Phase Multi-Dose-Level PET Image Reconstruction with Dose Level Awareness

Yuchen Fei, Yanmei Luo, Yan Wang, Jiaqi Cui, Yuanyuan Xu, Jiliu Zhou, Dinggang Shen

To obtain high-quality positron emission tomography (PET) while minimizing radiation exposure, a range of methods have been designed to reconstruct standard-dose PET (SPET) from corresponding low-dose PET (LPET) images. However, most current methods merely learn the mapping between single-dose-level LPET and SPET images, but omit the dose disparity of LPET images in clinical scenarios. In this paper, to reconstruct high-quality SPET images from multi-dose-level LPET images, we design a novel two-phase multi-dose-level PET reconstruction algorithm with dose level awareness, containing a pre-training phase and a SPET prediction phase. Specifically, the pre-training phase is devised to explore both fine-grained discriminative features and effective semantic representation. The SPET prediction phase adopts a coarse prediction network utilizing pre-learned dose level prior to generate preliminary result, and a refinement network to precisely preserve the details. Experiments on MICCAI 2022 Ultra-low Dose PET Imaging Challenge Dataset have demonstrated the superiority of our method.

Read more

4/11/2024