Development of Focused X-ray Luminescence Compute Tomography Imaging

Read original: arXiv:2406.07773 - Published 6/13/2024 by Yile Fang, Yibing Zhang, Changqing Li
Total Score

0

📊

Sign in to get full access

or

If you already have an account, we'll log you in

Overview

  • X-ray luminescence is a phenomenon where contrast agents absorb energy from X-ray photons and release a portion of that energy as visible and near-infrared photons.
  • X-ray luminescence computed tomography (XLCT) is a hybrid imaging technique that combines the high spatial resolution of X-ray imaging with the high sensitivity of optical imaging to detect tracer nanophosphors.

Plain English Explanation

X-ray luminescence occurs when certain materials, called contrast agents, are exposed to X-rays. The contrast agents absorb the energy from the X-rays and then release some of that energy as visible or near-infrared light. X-ray luminescence computed tomography (XLCT) is a type of medical imaging that takes advantage of this phenomenon. XLCT uses the high-resolution images from X-ray scans combined with the detailed information from the released light to create a more comprehensive picture of what's happening inside the body. This allows doctors to detect and monitor things like tumors or other abnormalities more effectively.

Technical Explanation

XLCT was introduced in the past decade as a way to combine the strengths of X-ray imaging and optical imaging. X-ray imaging provides high-resolution spatial information, but it can be less sensitive to certain types of biological markers or contrast agents. Optical imaging, on the other hand, is very sensitive to these markers, but has lower spatial resolution. XLCT leverages the high-resolution X-ray scans along with the detailed optical information from the X-ray luminescence to create a more complete and accurate image. This allows researchers and clinicians to better detect, monitor, and understand what's happening inside the body at a microscopic level.

Critical Analysis

The main advantage of XLCT is that it combines the best aspects of X-ray and optical imaging, overcoming the limitations of each individual modality. However, there are some potential challenges that the research in this area will need to address. For example, the sensitivity and specificity of the contrast agents used in XLCT will need to be carefully evaluated, and the trade-offs between spatial resolution and signal strength will need to be optimized. Additionally, the ability to accurately register and fuse the X-ray and optical data will be crucial for producing high-quality, clinically relevant images. Ongoing research in areas like modeling and simulation of charge-induced signals in photon-counting detectors may also help to further improve the performance and reliability of XLCT systems.

Conclusion

X-ray luminescence computed tomography (XLCT) is an innovative hybrid imaging technique that combines the strengths of X-ray and optical imaging to provide a more comprehensive view of the body's internal structures and processes. By leveraging the high spatial resolution of X-rays and the high sensitivity of optical imaging to detect specific contrast agents, XLCT has the potential to significantly improve the diagnosis and monitoring of various medical conditions. As the research in this field continues to evolve, XLCT may become an increasingly valuable tool in the arsenal of modern medical imaging technologies.



This summary was produced with help from an AI and may contain inaccuracies - check out the links to read the original source documents!

Follow @aimodelsfyi on 𝕏 →

Related Papers

📊

Total Score

0

Development of Focused X-ray Luminescence Compute Tomography Imaging

Yile Fang, Yibing Zhang, Changqing Li

X-ray luminescence is produced when contrast agents absorb energy from X-ray photons and release a portion of that energy by emitting photons in the visible and near-infrared range. X-ray luminescence computed tomography (XLCT) was introduced in the past decade as a hybrid molecular imaging modality combining the merits of both X-ray imaging (high spatial resolution) and optical imaging (high sensitivity to tracer nanophosphors).

Read more

6/13/2024

DiffuX2CT: Diffusion Learning to Reconstruct CT Images from Biplanar X-Rays
Total Score

0

DiffuX2CT: Diffusion Learning to Reconstruct CT Images from Biplanar X-Rays

Xuhui Liu, Zhi Qiao, Runkun Liu, Hong Li, Juan Zhang, Xiantong Zhen, Zhen Qian, Baochang Zhang

Computed tomography (CT) is widely utilized in clinical settings because it delivers detailed 3D images of the human body. However, performing CT scans is not always feasible due to radiation exposure and limitations in certain surgical environments. As an alternative, reconstructing CT images from ultra-sparse X-rays offers a valuable solution and has gained significant interest in scientific research and medical applications. However, it presents great challenges as it is inherently an ill-posed problem, often compromised by artifacts resulting from overlapping structures in X-ray images. In this paper, we propose DiffuX2CT, which models CT reconstruction from orthogonal biplanar X-rays as a conditional diffusion process. DiffuX2CT is established with a 3D global coherence denoising model with a new, implicit conditioning mechanism. We realize the conditioning mechanism by a newly designed tri-plane decoupling generator and an implicit neural decoder. By doing so, DiffuX2CT achieves structure-controllable reconstruction, which enables 3D structural information to be recovered from 2D X-rays, therefore producing faithful textures in CT images. As an extra contribution, we collect a real-world lumbar CT dataset, called LumbarV, as a new benchmark to verify the clinical significance and performance of CT reconstruction from X-rays. Extensive experiments on this dataset and three more publicly available datasets demonstrate the effectiveness of our proposal.

Read more

7/19/2024

🤷

Total Score

0

Reference-Free Multi-Modality Volume Registration of X-Ray Microscopy and Light-Sheet Fluorescence Microscopy

Siyuan Mei, Fuxin Fan, Mareike Thies, Mingxuan Gu, Fabian Wagner, Oliver Aust, Ina Erceg, Zeynab Mirzaei, Georgiana Neag, Yipeng Sun, Yixing Huang, Andreas Maier

Recently, X-ray microscopy (XRM) and light-sheet fluorescence microscopy (LSFM) have emerged as two pivotal imaging tools in preclinical research on bone remodeling diseases, offering micrometer-level resolution. Integrating these complementary modalities provides a holistic view of bone microstructures, facilitating function-oriented volume analysis across different disease cycles. However, registering such independently acquired large-scale volumes is extremely challenging under real and reference-free scenarios. This paper presents a fast two-stage pipeline for volume registration of XRM and LSFM. The first stage extracts the surface features and employs two successive point cloud-based methods for coarse alignment. The second stage fine-tunes the initial alignment using a modified cross-correlation method, ensuring precise volumetric registration. Moreover, we propose residual similarity as a novel metric to assess the alignment of two complementary modalities. The results imply robust gradual improvement across the stages. In the end, all correlating microstructures, particularly lacunae in XRM and bone cells in LSFM, are precisely matched, enabling new insights into bone diseases like osteoporosis which are a substantial burden in aging societies.

Read more

4/24/2024

X-ray nano-holotomography reconstruction with simultaneous probe retrieval
Total Score

0

X-ray nano-holotomography reconstruction with simultaneous probe retrieval

Viktor Nikitin, Marcus Carlsson, Doga Gursoy, Rajmund Mokso, Peter Cloetens

In conventional tomographic reconstruction, the pre-processing step includes flat-field correction, where each sample projection on the detector is divided by a reference image taken without the sample. When using coherent X-rays as probe, this approach overlooks the phase component of the illumination field (probe), leading to artifacts in phase-retrieved projection images, which are then propagated to the reconstructed 3D sample representation. The problem intensifies in nano-holotomography with focusing optics, that due to various imperfections create high-frequency components in the probe function. Here, we present a new iterative reconstruction scheme for holotomography, simultaneously retrieving the complex-valued probe function. Implemented on GPUs, this algorithm results in 3D reconstruction resolving twice thinner layers in a 3D ALD standard sample measured using nano-holotomography.

Read more

9/2/2024