X-ray nano-holotomography reconstruction with simultaneous probe retrieval

Read original: arXiv:2407.20304 - Published 9/2/2024 by Viktor Nikitin, Marcus Carlsson, Doga Gursoy, Rajmund Mokso, Peter Cloetens
Total Score

0

X-ray nano-holotomography reconstruction with simultaneous probe retrieval

Sign in to get full access

or

If you already have an account, we'll log you in

Overview

  • This research paper presents a new method for X-ray nano-holotomography reconstruction with simultaneous probe retrieval.
  • The method allows for high-resolution 3D imaging of samples while also recovering the imaging probe, which is important for achieving optimal image quality.
  • The approach combines advanced numerical algorithms and iterative reconstruction techniques to produce high-quality results.

Plain English Explanation

The paper describes a new way to create detailed 3D images using X-rays, while also determining the properties of the X-ray beam (the "probe") that is used to take the images. This is important because the quality of the final 3D image depends a lot on having an accurate understanding of the X-ray beam.

The researchers developed a computational method that can reconstruct the 3D structure of a sample and simultaneously figure out the characteristics of the X-ray beam. This allows them to produce very high-resolution 3D images without needing to separately measure the X-ray beam beforehand.

The key idea is to use advanced mathematical algorithms and iterative imaging techniques to optimize both the 3D image and the X-ray beam properties at the same time. This "simultaneous" approach is more efficient and can achieve better results than doing the two steps separately.

Overall, this new method represents an important advance in X-ray imaging that can enable researchers to obtain extremely detailed 3D visualizations of complex samples, with applications in fields like materials science, biology, and medicine.

Technical Explanation

The paper presents a novel approach for X-ray nano-holotomography reconstruction that enables simultaneous retrieval of the imaging probe. This is a significant advancement over previous methods that required separate, prior characterization of the probe.

The core of the technique is a joint optimization framework that iteratively updates both the 3D sample reconstruction and the probe function. This is achieved by formulating the holotomography problem as a constrained non-linear optimization task, where the objective is to minimize the discrepancy between the measured and simulated diffraction patterns while also enforcing physical constraints on the sample and probe.

The researchers leverage advanced numerical algorithms and iterative reconstruction techniques to efficiently solve this optimization problem. This allows them to obtain high-quality 3D reconstructions of the sample while simultaneously retrieving the probe function.

Importantly, the simultaneous probe retrieval enables better compensation of experimental imperfections, leading to improved resolution and fidelity of the final 3D images compared to approaches that require a separate probe calibration step.

Critical Analysis

The paper presents a robust and well-designed method that addresses an important challenge in X-ray nano-holotomography. The simultaneous probe retrieval is a clever innovation that enhances the capabilities of this imaging technique.

However, the authors acknowledge some limitations of their approach. For example, the method assumes a weakly scattering sample, which may not always be the case in practice. Additionally, the computational cost of the joint optimization can be significant, especially for large 3D volumes.

Further research could explore ways to improve the computational efficiency, such as by incorporating machine learning techniques to accelerate the optimization. Investigating the performance of the method on a broader range of sample types would also be valuable.

Overall, this paper presents an important advance in X-ray imaging that can enable researchers to obtain exceptionally detailed 3D visualizations of complex samples. The simultaneous probe retrieval is a key innovation that enhances the capabilities of this powerful imaging technique.

Conclusion

The research paper introduces a new method for X-ray nano-holotomography reconstruction that can simultaneously retrieve the imaging probe. This represents a significant advancement over previous approaches that required separate probe characterization.

The simultaneous optimization of the 3D sample reconstruction and probe function leads to improved image quality and fidelity, as it allows for better compensation of experimental imperfections. While the method has some limitations, it demonstrates the power of joint optimization techniques in advancing X-ray imaging capabilities.

This work has important implications for fields that rely on high-resolution 3D visualization, such as materials science, biology, and medicine. The ability to obtain detailed structural information while also recovering the imaging probe is a valuable tool that can drive new discoveries and insights.



This summary was produced with help from an AI and may contain inaccuracies - check out the links to read the original source documents!

Follow @aimodelsfyi on 𝕏 →

Related Papers

X-ray nano-holotomography reconstruction with simultaneous probe retrieval
Total Score

0

X-ray nano-holotomography reconstruction with simultaneous probe retrieval

Viktor Nikitin, Marcus Carlsson, Doga Gursoy, Rajmund Mokso, Peter Cloetens

In conventional tomographic reconstruction, the pre-processing step includes flat-field correction, where each sample projection on the detector is divided by a reference image taken without the sample. When using coherent X-rays as probe, this approach overlooks the phase component of the illumination field (probe), leading to artifacts in phase-retrieved projection images, which are then propagated to the reconstructed 3D sample representation. The problem intensifies in nano-holotomography with focusing optics, that due to various imperfections create high-frequency components in the probe function. Here, we present a new iterative reconstruction scheme for holotomography, simultaneously retrieving the complex-valued probe function. Implemented on GPUs, this algorithm results in 3D reconstruction resolving twice thinner layers in a 3D ALD standard sample measured using nano-holotomography.

Read more

9/2/2024

Near-Isotropic Sub-{AA}ngstrom 3D Resolution Phase Contrast Imaging Achieved by End-to-End Ptychographic Electron Tomography
Total Score

0

Near-Isotropic Sub-{AA}ngstrom 3D Resolution Phase Contrast Imaging Achieved by End-to-End Ptychographic Electron Tomography

Shengboy You, Andrey Romanov, Philipp Pelz

Three-dimensional atomic resolution imaging using transmission electron microscopes is a unique capability that requires challenging experiments. Linear electron tomography methods are limited by the missing wedge effect, requiring a high tilt range. Multislice ptychography can achieve deep sub-{AA}ngstrom resolution in the transverse direction, but the depth resolution is limited to 2 to 3 nanometers. In this paper, we propose and demonstrate an end-to-end approach to reconstructing the electrostatic potential volume of the sample directly from the 4D-STEM datasets. End-to-end multi-slice ptychographic tomography recovers several slices at each tomography tilt angle and compensates for the missing wedge effect. The algorithm is initially tested in simulation with a Pt@$mathrm{Al_2O_3}$ core-shell nanoparticle, where both heavy and light atoms are recovered in 3D from an unaligned 4D-STEM tilt series with a restricted tilt range of 90 degrees. We also demonstrate the algorithm experimentally, recovering a Te nanoparticle with sub-{AA}ngstrom resolution.

Read more

7/30/2024

↗️

Total Score

0

A high-performance reconstruction method for partially coherent ptychography

Wenhui Xu, Shoucong Ning, Pengju Sheng, Huixiang Lin, Angus I Kirkland, Yong Peng, Fucai Zhang

Ptychography is now integrated as a tool in mainstream microscopy allowing quantitative and high-resolution imaging capabilities over a wide field of view. However, its ultimate performance is inevitably limited by the available coherent flux when implemented using electrons or laboratory X-ray sources. We present a universal reconstruction algorithm with high tolerance to low coherence for both far-field and near-field ptychography. The approach is practical for partial temporal and spatial coherence and requires no prior knowledge of the source properties. Our initial visible-light and electron data show that the method can dramatically improve the reconstruction quality and accelerate the convergence rate of the reconstruction. The approach also integrates well into existing ptychographic engines. It can also improve mixed-state and numerical monochromatisation methods, requiring a smaller number of coherent modes or lower dimensionality of Krylov subspace while providing more stable and faster convergence. We propose that this approach could have significant impact on ptychography of weakly scattering samples.

Read more

6/12/2024

Fluorescence Diffraction Tomography using Explicit Neural Fields
Total Score

0

Fluorescence Diffraction Tomography using Explicit Neural Fields

Renzhi He, Yucheng Li, Junjie Chen, Yi Xue

Simultaneous imaging of fluorescence-labeled and label-free phase objects in the same sample provides distinct and complementary information. Most multimodal fluorescence-phase imaging operates in transmission mode, capturing fluorescence images and phase images separately or sequentially, which limits their practical application in vivo. Here, we develop fluorescence diffraction tomography (FDT) with explicit neural fields to reconstruct the 3D refractive index (RI) of phase objects from diffracted fluorescence images captured in reflection mode. The successful reconstruction of 3D RI using FDT relies on four key components: a coarse-to-fine structure, self-calibration, a differential multi-slice rendering model, and partially coherent masks. The explicit representation integrates with the coarse-to-fine structure for high-speed, high-resolution reconstruction, while the differential multi-slice rendering model enables self-calibration of fluorescence illumination, ensuring accurate forward image prediction and RI reconstruction. Partially coherent masks efficiently resolve discrepancies between the coherent light model and partially coherent light data. FDT successfully reconstructs the RI of 3D cultured label-free bovine myotubes in a 530 $times$ 530 $times$ 300 $mu m^3$ volume at 1024 $times$ 1024 pixels across 24 $z$-layers from fluorescence images, demonstrating high resolution and high accuracy 3D RI reconstruction of bulky and heterogeneous biological samples in vitro.

Read more