A Finger on the Pulse of Cardiovascular: Estimating Blood Pressure with Smartphone Photoplethysmography-Based Pulse Waveform Analysis

Read original: arXiv:2401.11117 - Published 7/25/2024 by Ivan Liu, Fangyuan Liu, Qi Zhong, Shiguang Ni
Total Score

0

🌐

Sign in to get full access

or

If you already have an account, we'll log you in

Overview

  • This study explores using smartphone cameras for continuous blood pressure (BP) monitoring as a cost-effective and accessible approach.
  • The researchers introduce four strategies to improve the accuracy and interpretability of smartphone-based photoplethysmography for BP estimation (SPW-BP).
  • The study analyzes data from 127 participants and compares smartphone-captured waveform features to standard BP monitoring devices.

Plain English Explanation

The researchers wanted to find a way to measure blood pressure using a smartphone camera. This could be more affordable and accessible than traditional blood pressure monitoring devices. However, using smartphone cameras for this purpose has had some accuracy and reliability issues in the past.

To address these challenges, the researchers tried four new strategies:

  1. They used techniques to improve the quality of the data, such as adjusting for the height of the person and removing any corrupted data.
  2. They analyzed over 20 different features of the waveform (the pattern of the pulse) to find the most useful ones for estimating blood pressure.
  3. They used a technique called SHAP analysis to make the machine learning models more transparent and easy to understand.
  4. They compared the smartphone-based blood pressure estimates to standard devices using common evaluation methods.

The researchers tested this approach on data from 127 people. They found that the smartphone-based waveform features were able to predict systolic blood pressure (the top number) with an average error of about 9-10 mmHg, and diastolic blood pressure (the bottom number) with an average error of about 6-8 mmHg.

While this is a promising start, the researchers found that the smartphone-based measurements still had some systematic biases and did not yet meet the accuracy standards required for medical devices. So smartphone cameras are not yet a reliable replacement for traditional blood pressure monitors.

Technical Explanation

The researchers employed four key strategies to enhance the accuracy and interpretability of smartphone-based photoplethysmography (SPW-BP) for blood pressure estimation:

  1. Data Quality Improvement: They utilized techniques such as height normalization, corrupt data removal, and boundary signal reconstruction to improve the quality of the smartphone-captured waveform data.

  2. Waveform Feature Analysis: The researchers conducted an in-depth analysis of over 20 waveform indicators across three categories (time-domain, frequency-domain, and morphological features) to identify the most predictive features for blood pressure estimation.

  3. Explainable AI: They employed SHAP (SHapley Additive exPlanations) analysis to ensure the transparency and interpretability of the machine learning models.

  4. Comparative Evaluation: The researchers utilized Bland-Altman analysis alongside AAMI and BHS standards to thoroughly evaluate the accuracy of the smartphone-based BP estimates.

The analysis of data from 127 participants showed a significant correlation between the smartphone-captured waveform features and those from standard BP monitoring devices. Using multiple linear regression within a cross-validation framework, the waveform variables were able to predict systolic blood pressure (SBP) with a mean absolute error (MAE) of 9.86 ± 6.78 mmHg and diastolic blood pressure (DBP) with an MAE of 8.01 ± 5.15 mmHg.

Further application of Random Forest models improved the prediction accuracy, reducing the MAE for SBP to 8.91 ± 6.30 mmHg and for DBP to 6.68 ± 4.54 mmHg. The SHAP analysis identified key waveform features that were most important for improving the BP estimation.

However, the Bland-Altman analysis revealed systematic biases, and the overall accuracy did not meet the AAMI and BHS standards for medical devices. The researchers conclude that while smartphone-based PPG technology shows potential, it is not yet a viable alternative to traditional blood pressure monitoring devices.

Critical Analysis

The researchers acknowledge several limitations and areas for further research in their paper:

  • The study was conducted in a controlled laboratory setting, and the performance of the SPW-BP approach may differ in real-world, unsupervised environments.
  • The sample size of 127 participants, while reasonable for an initial study, may not be sufficient to fully capture the diversity of blood pressure patterns and waveforms in the population.
  • The researchers suggest that incorporating additional waveform features, such as those from other camera-based vitals measurement techniques, could further improve the accuracy of the BP estimation.
  • The study did not investigate the long-term reliability and stability of the SPW-BP approach, which would be crucial for its use in continuous monitoring applications.

While the researchers have made significant progress in enhancing the interpretability and accuracy of smartphone-based blood pressure estimation, the results still do not meet the stringent standards required for medical devices. Continued research and development will be necessary to overcome the remaining challenges before smartphone cameras can be considered a viable alternative to traditional blood pressure monitoring tools.

Conclusion

This study explores the use of smartphone cameras for continuous blood pressure monitoring, a promising approach that could provide a more cost-effective and accessible solution. The researchers introduced four innovative strategies to address the limitations in accuracy and interpretability of previous smartphone-based photoplethysmography (SPW-BP) methods.

Through a comprehensive analysis of data from 127 participants, the researchers demonstrated that smartphone-captured waveform features can be used to estimate blood pressure with reasonable accuracy. However, the results still fall short of the standards required for medical devices, and the researchers identified several areas for further improvement and validation.

While the findings suggest that smartphone-based blood pressure monitoring has the potential to be a useful tool, particularly in resource-constrained settings, continued research and development will be necessary before it can be considered a reliable replacement for traditional monitoring devices. The researchers have laid the groundwork for further advancements in this field, which could ultimately lead to more accessible and affordable blood pressure monitoring solutions.



This summary was produced with help from an AI and may contain inaccuracies - check out the links to read the original source documents!

Follow @aimodelsfyi on 𝕏 →

Related Papers

🌐

Total Score

0

A Finger on the Pulse of Cardiovascular: Estimating Blood Pressure with Smartphone Photoplethysmography-Based Pulse Waveform Analysis

Ivan Liu, Fangyuan Liu, Qi Zhong, Shiguang Ni

Utilizing mobile phone cameras for continuous blood pressure (BP) monitoring presents a cost-effective and accessible approach, yet it is challenged by limitations in accuracy and interpretability. This study introduces four innovative strategies to enhance smartphone-based photoplethysmography for BP estimation (SPW-BP), addressing the interpretability-accuracy dilemma. First, we employ often-neglected data-quality improvement techniques, such as height normalization, corrupt data removal, and boundary signal reconstruction. Second, we conduct a comprehensive analysis of thirty waveform indicators across three categories to identify the most predictive features. Third, we use SHapley Additive exPlanations (SHAP) analysis to ensure the transparency and explainability of machine learning outcomes. Fourth, we utilize Bland-Altman analysis alongside AAMI and BHS standards for comparative evaluation. Data from 127 participants demonstrated a significant correlation between smartphone-captured waveform features and those from standard BP monitoring devices. Employing multiple linear regression within a cross-validation framework, waveform variables predicted systolic blood pressure (SBP) with a mean absolute error (MAE) of 3.08-16.64 mmHg and diastolic blood pressure (DBP) with an MAE of 2.86-13.16 mmHg. Further application of Random Forest models significantly improved the prediction MAE for SBP to 2.61-15.21 mmHg and for DBP to 2.14-11.22 mmHg, indicating enhanced predictive accuracy. Correlation and SHAP analysis identified key features for improving BP estimation. However, Bland-Altman analysis revealed systematic biases, and MAE analysis showed that the results did not meet AAMI and BHS accuracy standards. Our findings highlight the potential of SPW-BP, yet suggest that smartphone PPG technology is not yet a viable alternative to traditional medical devices for BP measurement.

Read more

7/25/2024

Phase-shifted remote photoplethysmography for estimating heart rate and blood pressure from facial video
Total Score

0

Phase-shifted remote photoplethysmography for estimating heart rate and blood pressure from facial video

Gyutae Hwang, Sang Jun Lee

Human health can be critically affected by cardiovascular diseases, such as hypertension, arrhythmias, and stroke. Heart rate and blood pressure are important biometric information for the monitoring of cardiovascular system and early diagnosis of cardiovascular diseases. Existing methods for estimating the heart rate are based on electrocardiography and photoplethyomography, which require contacting the sensor to the skin surface. Moreover, catheter and cuff-based methods for measuring blood pressure cause inconvenience and have limited applicability. Therefore, in this thesis, we propose a vision-based method for estimating the heart rate and blood pressure. This thesis proposes a 2-stage deep learning framework consisting of a dual remote photoplethysmography network (DRP-Net) and bounded blood pressure network (BBP-Net). In the first stage, DRP-Net infers remote photoplethysmography (rPPG) signals for the acral and facial regions, and these phase-shifted rPPG signals are utilized to estimate the heart rate. In the second stage, BBP-Net integrates temporal features and analyzes phase discrepancy between the acral and facial rPPG signals to estimate SBP and DBP values. To improve the accuracy of estimating the heart rate, we employed a data augmentation method based on a frame interpolation model. Moreover, we designed BBP-Net to infer blood pressure within a predefined range by incorporating a scaled sigmoid function. Our method resulted in estimating the heart rate with the mean absolute error (MAE) of 1.78 BPM, reducing the MAE by 34.31 % compared to the recent method, on the MMSE-HR dataset. The MAE for estimating the systolic blood pressure (SBP) and diastolic blood pressure (DBP) were 10.19 mmHg and 7.09 mmHg. On the V4V dataset, the MAE for the heart rate, SBP, and DBP were 3.83 BPM, 13.64 mmHg, and 9.4 mmHg, respectively.

Read more

8/27/2024

Total Score

0

Exploring the limitations of blood pressure estimation using the photoplethysmography signal

Felipe M. Dias, Diego A. C. Cardenas, Marcelo A. F. Toledo, Filipe A. C. Oliveira, Estela Ribeiro, Jose E. Krieger, Marco A. Gutierrez

Hypertension, a leading contributor to cardiovascular morbidity, underscores the need for accurate and continuous blood pressure (BP) monitoring. Photoplethysmography (PPG) presents a promising approach to this end. However, the precision of BP estimates derived from PPG signals has been the subject of ongoing debate, necessitating a comprehensive evaluation of their effectiveness and constraints. We developed a calibration-based Siamese ResNet model for BP estimation, using a signal input paired with a reference BP reading. We compared the use of normalized PPG (N-PPG) against the normalized Invasive Arterial Blood Pressure (N-IABP) signals as input. The N-IABP signals do not directly present systolic and diastolic values but theoretically provide a more accurate BP measure than PPG signals since it is a direct pressure sensor inside the body. Our strategy establishes a critical benchmark for PPG performance, realistically calibrating expectations for PPG's BP estimation capabilities. Nonetheless, we compared the performance of our models using different signal-filtering conditions to evaluate the impact of filtering on the results. We evaluated our method using the AAMI and the BHS standards employing the VitalDB dataset. The N-IABP signals meet with AAMI standards for both Systolic Blood Pressure (SBP) and Diastolic Blood Pressure (DBP), with errors of 1.29+-6.33mmHg for systolic pressure and 1.17+-5.78mmHg for systolic and diastolic pressure respectively for the raw N-IABP signal. In contrast, N-PPG signals, in their best setup, exhibited inferior performance than N-IABP, presenting 1.49+-11.82mmHg and 0.89+-7.27mmHg for systolic and diastolic pressure respectively. Our findings highlight the potential and limitations of employing PPG for BP estimation, showing that these signals contain information correlated to BP but may not be sufficient for predicting it accurately.

Read more

4/26/2024

Large Language Models for Cuffless Blood Pressure Measurement From Wearable Biosignals
Total Score

0

Large Language Models for Cuffless Blood Pressure Measurement From Wearable Biosignals

Zengding Liu, Chen Chen, Jiannong Cao, Minglei Pan, Jikui Liu, Nan Li, Fen Miao, Ye Li

Large language models (LLMs) have captured significant interest from both academia and industry due to their impressive performance across various textual tasks. However, the potential of LLMs to analyze physiological time-series data remains an emerging research field. Particularly, there is a notable gap in the utilization of LLMs for analyzing wearable biosignals to achieve cuffless blood pressure (BP) measurement, which is critical for the management of cardiovascular diseases. This paper presents the first work to explore the capacity of LLMs to perform cuffless BP estimation based on wearable biosignals. We extracted physiological features from electrocardiogram (ECG) and photoplethysmogram (PPG) signals and designed context-enhanced prompts by combining these features with BP domain knowledge and user information. Subsequently, we adapted LLMs to BP estimation tasks through fine-tuning. To evaluate the proposed approach, we conducted assessments of ten advanced LLMs using a comprehensive public dataset of wearable biosignals from 1,272 participants. The experimental results demonstrate that the optimally fine-tuned LLM significantly surpasses conventional task-specific baselines, achieving an estimation error of 0.00 $pm$ 9.25 mmHg for systolic BP and 1.29 $pm$ 6.37 mmHg for diastolic BP. Notably, the ablation studies highlight the benefits of our context enhancement strategy, leading to an 8.9% reduction in mean absolute error for systolic BP estimation. This paper pioneers the exploration of LLMs for cuffless BP measurement, providing a potential solution to enhance the accuracy of cuffless BP measurement.

Read more

7/8/2024