LpQcM: Adaptable Lesion-Quantification-Consistent Modulation for Deep Learning Low-Count PET Image Denoising

2404.17994

YC

0

Reddit

0

Published 4/30/2024 by Menghua Xia, Huidong Xie, Qiong Liu, Bo Zhou, Hanzhong Wang, Biao Li, Axel Rominger, Kuangyu Shi, Georges EI Fakhri, Chi Liu

🤿

Abstract

Deep learning-based positron emission tomography (PET) image denoising offers the potential to reduce radiation exposure and scanning time by transforming low-count images into high-count equivalents. However, existing methods typically blur crucial details, leading to inaccurate lesion quantification. This paper proposes a lesion-perceived and quantification-consistent modulation (LpQcM) strategy for enhanced PET image denoising, via employing downstream lesion quantification analysis as auxiliary tools. The LpQcM is a plug-and-play design adaptable to a wide range of model architectures, modulating the sampling and optimization procedures of model training without adding any computational burden to the inference phase. Specifically, the LpQcM consists of two components, the lesion-perceived modulation (LpM) and the multiscale quantification-consistent modulation (QcM). The LpM enhances lesion contrast and visibility by allocating higher sampling weights and stricter loss criteria to lesion-present samples determined by an auxiliary segmentation network than lesion-absent ones. The QcM further emphasizes accuracy of quantification for both the mean and maximum standardized uptake value (SUVmean and SUVmax) across multiscale sub-regions throughout the entire image, thereby enhancing the overall image quality. Experiments conducted on large PET datasets from multiple centers and vendors, and varying noise levels demonstrated the LpQcM efficacy across various denoising frameworks. Compared to frameworks without LpQcM, the integration of LpQcM reduces the lesion SUVmean bias by 2.92% on average and increases the peak signal-to-noise ratio (PSNR) by 0.34 on average, for denoising images of extremely low-count levels below 10%.

Create account to get full access

or

If you already have an account, we'll log you in

Overview

  • This paper proposes a new deep learning-based approach for improving positron emission tomography (PET) image quality by reducing noise while preserving crucial details.
  • The proposed "lesion-perceived and quantification-consistent modulation" (LpQcM) strategy aims to enhance lesion contrast and accuracy of quantitative measurements, such as standardized uptake value (SUV).
  • LpQcM can be integrated into various existing PET denoising model architectures without increasing computational burden during inference.

Plain English Explanation

PET scans are medical imaging tests that use a small amount of radioactive material to create detailed images of the inside of the body. However, low-dose PET scans can result in noisy, low-quality images that make it difficult to accurately identify and measure lesions (abnormal growths).

The researchers in this paper developed a new deep learning-based approach called LpQcM to address this issue. LpQcM is designed to transform low-quality, low-dose PET images into higher-quality equivalents, while specifically preserving the contrast and quantitative measurements of lesions.

The key idea is to use an auxiliary lesion segmentation network to identify areas with lesions during the training process. LpQcM then applies higher weight and stricter loss criteria to the lesion-containing regions, ensuring the model prioritizes preserving important diagnostic details. It also emphasizes accurate quantification of both the average (SUVmean) and maximum (SUVmax) radiotracer uptake values across the entire image.

By incorporating these targeted modifications to the training process, LpQcM is able to produce denoised PET images that maintain crucial lesion information, leading to more accurate clinical interpretation and disease monitoring compared to existing denoising methods.

Technical Explanation

The LpQcM strategy consists of two key components:

  1. Lesion-Perceived Modulation (LpM): This module uses an auxiliary lesion segmentation network to identify regions containing lesions in the training data. It then applies higher sampling weights and stricter loss criteria to these lesion-present samples, forcing the denoising model to prioritize preserving lesion contrast and visibility.

  2. Multiscale Quantification-Consistent Modulation (QcM): This component emphasizes the accuracy of quantitative measurements, such as SUVmean and SUVmax, across different sub-regions of the entire image. By applying additional loss terms to ensure fidelity of these metrics, the model is encouraged to generate denoised images that maintain the original radiometric properties.

The researchers evaluated LpQcM by integrating it into various existing PET denoising frameworks and testing on large datasets from multiple clinical centers and vendors. Compared to the original denoising models, the LpQcM-enhanced versions demonstrated reduced lesion SUVmean bias by 2.92% on average and increased peak signal-to-noise ratio (PSNR) by 0.34 on average, especially for extremely low-count PET images.

Critical Analysis

The paper presents a compelling and well-designed approach to improving PET image quality while preserving crucial diagnostic details. The LpQcM strategy is a flexible, plug-and-play module that can be integrated into various denoising model architectures without increasing computational complexity during inference.

One potential limitation is the reliance on an auxiliary lesion segmentation network, which adds an extra step to the pipeline and may introduce errors if the segmentation is inaccurate. The authors acknowledge this and suggest exploring end-to-end training of the denoising and segmentation components as a future direction.

Additionally, the paper focuses primarily on evaluating quantitative metrics like SUV and PSNR. While these are important for clinical applications, it would be valuable to also assess the impact of LpQcM on qualitative image features and clinical interpretation by radiologists.

Overall, this research represents a promising advance in the field of PET image enhancement, with the potential to improve patient care by reducing radiation exposure and scanning time while maintaining diagnostic accuracy.

Conclusion

This paper presents a novel deep learning-based approach called LpQcM for enhancing PET image quality by preserving crucial lesion details and quantitative measurements. By incorporating targeted modulations to the training process, LpQcM is able to produce denoised PET images that outperform existing methods, especially for extremely low-count scans.

The flexible, plug-and-play design of LpQcM makes it a compelling solution for clinical PET imaging, with the potential to reduce radiation exposure and scanning time while maintaining diagnostic accuracy. As the field of medical imaging continues to advance, strategies like LpQcM will play an important role in improving patient care and outcomes.



This summary was produced with help from an AI and may contain inaccuracies - check out the links to read the original source documents!

Related Papers

📈

Full-dose Whole-body PET Synthesis from Low-dose PET Using High-efficiency Denoising Diffusion Probabilistic Model: PET Consistency Model

Shaoyan Pan, Elham Abouei, Junbo Peng, Joshua Qian, Jacob F Wynne, Tonghe Wang, Chih-Wei Chang, Justin Roper, Jonathon A Nye, Hui Mao, Xiaofeng Yang

YC

0

Reddit

0

Objective: Positron Emission Tomography (PET) has been a commonly used imaging modality in broad clinical applications. One of the most important tradeoffs in PET imaging is between image quality and radiation dose: high image quality comes with high radiation exposure. Improving image quality is desirable for all clinical applications while minimizing radiation exposure is needed to reduce risk to patients. Approach: We introduce PET Consistency Model (PET-CM), an efficient diffusion-based method for generating high-quality full-dose PET images from low-dose PET images. It employs a two-step process, adding Gaussian noise to full-dose PET images in the forward diffusion, and then denoising them using a PET Shifted-window Vision Transformer (PET-VIT) network in the reverse diffusion. The PET-VIT network learns a consistency function that enables direct denoising of Gaussian noise into clean full-dose PET images. PET-CM achieves state-of-the-art image quality while requiring significantly less computation time than other methods. Results: In experiments comparing eighth-dose to full-dose images, PET-CM demonstrated impressive performance with NMAE of 1.278+/-0.122%, PSNR of 33.783+/-0.824dB, SSIM of 0.964+/-0.009, NCC of 0.968+/-0.011, HRS of 4.543, and SUV Error of 0.255+/-0.318%, with an average generation time of 62 seconds per patient. This is a significant improvement compared to the state-of-the-art diffusion-based model with PET-CM reaching this result 12x faster. Similarly, in the quarter-dose to full-dose image experiments, PET-CM delivered competitive outcomes, achieving an NMAE of 0.973+/-0.066%, PSNR of 36.172+/-0.801dB, SSIM of 0.984+/-0.004, NCC of 0.990+/-0.005, HRS of 4.428, and SUV Error of 0.151+/-0.192% using the same generation process, which underlining its high quantitative and clinical precision in both denoising scenario.

Read more

4/10/2024

📈

MCAD: Multi-modal Conditioned Adversarial Diffusion Model for High-Quality PET Image Reconstruction

Jiaqi Cui, Xinyi Zeng, Pinxian Zeng, Bo Liu, Xi Wu, Jiliu Zhou, Yan Wang

YC

0

Reddit

0

Radiation hazards associated with standard-dose positron emission tomography (SPET) images remain a concern, whereas the quality of low-dose PET (LPET) images fails to meet clinical requirements. Therefore, there is great interest in reconstructing SPET images from LPET images. However, prior studies focus solely on image data, neglecting vital complementary information from other modalities, e.g., patients' clinical tabular, resulting in compromised reconstruction with limited diagnostic utility. Moreover, they often overlook the semantic consistency between real SPET and reconstructed images, leading to distorted semantic contexts. To tackle these problems, we propose a novel Multi-modal Conditioned Adversarial Diffusion model (MCAD) to reconstruct SPET images from multi-modal inputs, including LPET images and clinical tabular. Specifically, our MCAD incorporates a Multi-modal conditional Encoder (Mc-Encoder) to extract multi-modal features, followed by a conditional diffusion process to blend noise with multi-modal features and gradually map blended features to the target SPET images. To balance multi-modal inputs, the Mc-Encoder embeds Optimal Multi-modal Transport co-Attention (OMTA) to narrow the heterogeneity gap between image and tabular while capturing their interactions, providing sufficient guidance for reconstruction. In addition, to mitigate semantic distortions, we introduce the Multi-Modal Masked Text Reconstruction (M3TRec), which leverages semantic knowledge extracted from denoised PET images to restore the masked clinical tabular, thereby compelling the network to maintain accurate semantics during reconstruction. To expedite the diffusion process, we further introduce an adversarial diffusive network with a reduced number of diffusion steps. Experiments show that our method achieves the state-of-the-art performance both qualitatively and quantitatively.

Read more

6/21/2024

Dose-aware Diffusion Model for 3D Low-dose PET: Multi-institutional Validation with Reader Study and Real Low-dose Data

Dose-aware Diffusion Model for 3D Low-dose PET: Multi-institutional Validation with Reader Study and Real Low-dose Data

Huidong Xie, Weijie Gan, Bo Zhou, Ming-Kai Chen, Michal Kulon, Annemarie Boustani, Benjamin A. Spencer, Reimund Bayerlein, Xiongchao Chen, Qiong Liu, Xueqi Guo, Menghua Xia, Yinchi Zhou, Hui Liu, Liang Guo, Hongyu An, Ulugbek S. Kamilov, Hanzhong Wang, Biao Li, Axel Rominger, Kuangyu Shi, Ge Wang, Ramsey D. Badawi, Chi Liu

YC

0

Reddit

0

As PET imaging is accompanied by radiation exposure and potentially increased cancer risk, reducing radiation dose in PET scans without compromising the image quality is an important topic. Deep learning (DL) techniques have been investigated for low-dose PET imaging. However, existing models have often resulted in compromised image quality when achieving low-dose PET and have limited generalizability to different image noise-levels, acquisition protocols, patient populations, and hospitals. Recently, diffusion models have emerged as the new state-of-the-art generative model to generate high-quality samples and have demonstrated strong potential for medical imaging tasks. However, for low-dose PET imaging, existing diffusion models failed to generate consistent 3D reconstructions, unable to generalize across varying noise-levels, often produced visually-appealing but distorted image details, and produced images with biased tracer uptake. Here, we develop DDPET-3D, a dose-aware diffusion model for 3D low-dose PET imaging to address these challenges. Collected from 4 medical centers globally with different scanners and clinical protocols, we extensively evaluated the proposed model using a total of 9,783 18F-FDG studies (1,596 patients) with low-dose/low-count levels ranging from 1% to 50%. With a cross-center, cross-scanner validation, the proposed DDPET-3D demonstrated its potential to generalize to different low-dose levels, different scanners, and different clinical protocols. As confirmed with reader studies performed by nuclear medicine physicians, the proposed method produced superior denoised results that are comparable to or even better than the 100% full-count images as well as previous DL baselines. The presented results show the potential of achieving low-dose PET while maintaining image quality. Lastly, a group of real low-dose scans was also included for evaluation.

Read more

5/24/2024

Towards AI Lesion Tracking in PET/CT Imaging: A Siamese-based CNN Pipeline applied on PSMA PET/CT Scans

Towards AI Lesion Tracking in PET/CT Imaging: A Siamese-based CNN Pipeline applied on PSMA PET/CT Scans

Stefan P. Hein, Manuel Schultheiss, Andrei Gafita, Raphael Zaum, Farid Yagubbayli, Robert Tauber, Isabel Rauscher, Matthias Eiber, Franz Pfeiffer, Wolfgang A. Weber

YC

0

Reddit

0

Assessing tumor response to systemic therapies is one of the main applications of PET/CT. Routinely, only a small subset of index lesions out of multiple lesions is analyzed. However, this operator dependent selection may bias the results due to possible significant inter-metastatic heterogeneity of response to therapy. Automated, AI based approaches for lesion tracking hold promise in enabling the analysis of many more lesions and thus providing a better assessment of tumor response. This work introduces a Siamese CNN approach for lesion tracking between PET/CT scans. Our approach is applied on the laborious task of tracking a high number of bone lesions in full-body baseline and follow-up [68Ga]Ga- or [18F]F-PSMA PET/CT scans after two cycles of [177Lu]Lu-PSMA therapy of metastatic castration resistant prostate cancer patients. Data preparation includes lesion segmentation and affine registration. Our algorithm extracts suitable lesion patches and forwards them into a Siamese CNN trained to classify the lesion patch pairs as corresponding or non-corresponding lesions. Experiments have been performed with different input patch types and a Siamese network in 2D and 3D. The CNN model successfully learned to classify lesion assignments, reaching a lesion tracking accuracy of 83 % in its best configuration with an AUC = 0.91. For remaining lesions the pipeline accomplished a re-identification rate of 89 %. We proved that a CNN may facilitate the tracking of multiple lesions in PSMA PET/CT scans. Future clinical studies are necessary if this improves the prediction of the outcome of therapies.

Read more

6/28/2024