Heart Rate and its Variability from Short-term ECG Recordings as Biomarkers for Detecting Mild Cognitive Impairment in Indian Population

Read original: arXiv:2408.02296 - Published 8/6/2024 by Anjo Xavier, Sneha Noble, Justin Joseph, Thomas Gregor Issac
Total Score

0

🎯

Sign in to get full access

or

If you already have an account, we'll log you in

Overview

  • The study investigates the influence of Mild Cognitive Impairment (MCI) on heart rate (HR) and heart rate variability (HRV) in the Indian population.
  • Researchers designed a signal processing pipeline to detect R-wave peaks and compute HR and HRV features from 10-second ECG recordings for point-of-care applications.
  • The study cohort included 297 urban participants, with 48.48% male and 51.51% female.
  • MCI was detected in 19.19% of participants using the Addenbrooke's Cognitive Examination-III (ACE-III).

Plain English Explanation

The researchers wanted to understand how Mild Cognitive Impairment (MCI) affects a person's heart rate (HR) and heart rate variability (HRV) in the Indian population. MCI is a condition where someone has minor memory or thinking problems that are more than normal age-related changes, but not severe enough to be considered dementia.

The researchers developed a system to analyze 10-second electrocardiogram (ECG) recordings to measure a person's HR and HRV. They studied 297 people from urban India, about half men and half women. Using a cognitive test called the Addenbrooke's Cognitive Examination-III, they found that 19.19% of the participants had MCI.

The researchers looked at statistical measures of the participants' beat-to-beat heart rate intervals, including the average, variation, and how much the intervals changed from one beat to the next. They found that people with MCI tended to have higher heart rates and more variation in their heart rates compared to those without MCI.

Technical Explanation

The researchers designed a signal processing pipeline to detect the R-wave peaks in ECG recordings and compute HR and HRV features from 10-second windows. This allowed them to analyze HR and HRV for potential use in point-of-care applications.

The study cohort consisted of 297 urban participants, with 48.48% male and 51.51% female. MCI was detected in 19.19% of the participants using the Addenbrooke's Cognitive Examination-III (ACE-III).

The researchers computed statistical features of the beat-to-beat heart rate intervals, including:

  • Central tendency: mean and root mean square (RMS) of the normal-to-normal (NN) intervals
  • Dispersion: standard deviation (SD) of all NN intervals (SDNN) and root mean square of successive differences of NN intervals (RMSSD)

The Wilcoxon rank sum test showed that the mean NN interval, RMS of NN intervals, SDNN, and RMSSD differed significantly between the MCI and non-MCI groups.

Machine learning classifiers like Support Vector Machine (SVM), Discriminant Analysis (DA), and Naive Bayes (NB) achieved high accuracy (80.80%) in distinguishing MCI from non-MCI using the HR and HRV features.

Individuals with MCI were observed to have higher heart rates compared to healthy subjects. The researchers concluded that HR and HRV can be considered as potential biomarkers for detecting MCI.

Critical Analysis

The paper provides a robust methodology for analyzing HR and HRV features to detect MCI, which could have important implications for early diagnosis and intervention. However, the study is limited to a relatively small urban cohort in India, and the findings may not be generalizable to other populations or settings.

The researchers acknowledge that further research is needed to validate the findings in larger and more diverse samples, as well as to explore the underlying physiological mechanisms linking MCI to autonomic dysfunction. Additionally, the use of HR and HRV as diagnostic biomarkers should be considered in the context of other clinical and cognitive assessments, as they may not be sufficient on their own for accurate MCI detection.

Conclusion

This study suggests that HR and HRV measures can potentially serve as biomarkers for detecting Mild Cognitive Impairment (MCI) in the Indian population. By designing a robust signal processing pipeline, the researchers were able to analyze ECG data and identify statistically significant differences in HR and HRV features between individuals with and without MCI.

These findings contribute to our understanding of the relationship between autonomic dysfunction and neurodegenerative disorders, and could inform the development of point-of-care diagnostic tools for early detection of MCI. However, further validation in larger and more diverse populations is needed to fully establish the clinical utility of these HR and HRV-based biomarkers.



This summary was produced with help from an AI and may contain inaccuracies - check out the links to read the original source documents!

Follow @aimodelsfyi on 𝕏 →

Related Papers

🎯

Total Score

0

Heart Rate and its Variability from Short-term ECG Recordings as Biomarkers for Detecting Mild Cognitive Impairment in Indian Population

Anjo Xavier, Sneha Noble, Justin Joseph, Thomas Gregor Issac

Alterations in Heart Rate (HR) and Heart Rate Variability (HRV) can reflect autonomic dysfunction associated with neurodegeneration. We investigate the influence of Mild Cognitive Impairment (MCI) on HR and its variability measures in the Indian population by designing a complete signal processing pipeline to detect the R-wave peaks and compute HR and HRV features from ECG recordings of 10 seconds, for point-of-care applications. The study cohort involves 297 urban participants, among which 48.48% are male and 51.51% are female. From the Addenbrooke's Cognitive Examination-III (ACE-III), MCI is detected in 19.19% of participants and the rest, 80.8% of them are cognitively healthy. Statistical features like central tendency (mean and root mean square (RMS) of the Normal-to-Normal (NN) intervals) and dispersion (standard deviation (SD) of all NN intervals (SDNN) and root mean square of successive differences of NN intervals (RMSSD)) of beat-to-beat intervals are computed. The Wilcoxon rank sum test reveals that mean of NN intervals (p = 0.0021), the RMS of NN intervals (p = 0.0014), the SDNN (p = 0.0192) and the RMSSD (p = 0.0206) values differ significantly between MCI and non-MCI classes, for a level of significance, 0.05. Machine learning classifiers like, Support Vector Machine (SVM), Discriminant Analysis (DA) and Naive Bayes (NB) driven by mean NN intervals, RMS, SDNN and RMSSD, show a high accuracy of 80.80% on each individual feature input. Individuals with MCI are observed to have comparatively higher HR than healthy subjects. HR and its variability can be considered as potential biomarkers for detecting MCI.

Read more

8/6/2024

Improving Machine Learning Based Sepsis Diagnosis Using Heart Rate Variability
Total Score

0

Improving Machine Learning Based Sepsis Diagnosis Using Heart Rate Variability

Sai Balaji, Christopher Sun, Anaiy Somalwar

The early and accurate diagnosis of sepsis is critical for enhancing patient outcomes. This study aims to use heart rate variability (HRV) features to develop an effective predictive model for sepsis detection. Critical HRV features are identified through feature engineering methods, including statistical bootstrapping and the Boruta algorithm, after which XGBoost and Random Forest classifiers are trained with differential hyperparameter settings. In addition, ensemble models are constructed to pool the prediction probabilities of high-recall and high-precision classifiers and improve model performance. Finally, a neural network model is trained on the HRV features, achieving an F1 score of 0.805, a precision of 0.851, and a recall of 0.763. The best-performing machine learning model is compared to this neural network through an interpretability analysis, where Local Interpretable Model-agnostic Explanations are implemented to determine decision-making criterion based on numerical ranges and thresholds for specific features. This study not only highlights the efficacy of HRV in automated sepsis diagnosis but also increases the transparency of black box outputs, maximizing clinical applicability.

Read more

8/7/2024

Leveraging Persistent Homology for Differential Diagnosis of Mild Cognitive Impairment
Total Score

0

Leveraging Persistent Homology for Differential Diagnosis of Mild Cognitive Impairment

Ninad Aithal, Debanjali Bhattacharya, Neelam Sinha, Thomas Gregor Issac

Mild cognitive impairment (MCI) is characterized by subtle changes in cognitive functions, often associated with disruptions in brain connectivity. The present study introduces a novel fine-grained analysis to examine topological alterations in neurodegeneration pertaining to six different brain networks of MCI subjects (Early/Late MCI). To achieve this, fMRI time series from two distinct populations are investigated: (i) the publicly accessible ADNI dataset and (ii) our in-house dataset. The study utilizes sliding window embedding to convert each fMRI time series into a sequence of 3-dimensional vectors, facilitating the assessment of changes in regional brain topology. Distinct persistence diagrams are computed for Betti descriptors of dimension-0, 1, and 2. Wasserstein distance metric is used to quantify differences in topological characteristics. We have examined both (i) ROI-specific inter-subject interactions and (ii) subject-specific inter-ROI interactions. Further, a new deep learning model is proposed for classification, achieving a maximum classification accuracy of 95% for the ADNI dataset and 85% for the in-house dataset. This methodology is further adapted for the differential diagnosis of MCI sub-types, resulting in a peak accuracy of 76.5%, 91.1% and 80% in classifying HC Vs. EMCI, HC Vs. LMCI and EMCI Vs. LMCI, respectively. We showed that the proposed approach surpasses current state-of-the-art techniques designed for classifying MCI and its sub-types using fMRI.

Read more

8/29/2024

Model-driven Heart Rate Estimation and Heart Murmur Detection based on Phonocardiogram
Total Score

0

Model-driven Heart Rate Estimation and Heart Murmur Detection based on Phonocardiogram

Jingping Nie, Ran Liu, Behrooz Mahasseni, Erdrin Azemi, Vikramjit Mitra

Acoustic signals are crucial for health monitoring, particularly heart sounds which provide essential data like heart rate and detect cardiac anomalies such as murmurs. This study utilizes a publicly available phonocardiogram (PCG) dataset to estimate heart rate using model-driven methods and extends the best-performing model to a multi-task learning (MTL) framework for simultaneous heart rate estimation and murmur detection. Heart rate estimates are derived using a sliding window technique on heart sound snippets, analyzed with a combination of acoustic features (Mel spectrogram, cepstral coefficients, power spectral density, root mean square energy). Our findings indicate that a 2D convolutional neural network (textbf{texttt{2dCNN}}) is most effective for heart rate estimation, achieving a mean absolute error (MAE) of 1.312 bpm. We systematically investigate the impact of different feature combinations and find that utilizing all four features yields the best results. The MTL model (textbf{texttt{2dCNN-MTL}}) achieves accuracy over 95% in murmur detection, surpassing existing models, while maintaining an MAE of 1.636 bpm in heart rate estimation, satisfying the requirements stated by Association for the Advancement of Medical Instrumentation (AAMI).

Read more

7/29/2024