iKalibr-RGBD: Partially-Specialized Target-Free Visual-Inertial Spatiotemporal Calibration For RGBDs via Continuous-Time Velocity Estimation

Read original: arXiv:2409.07116 - Published 9/12/2024 by Shuolong Chen, Xingxing Li, Shengyu Li, Yuxuan Zhou
Total Score

0

iKalibr-RGBD: Partially-Specialized Target-Free Visual-Inertial Spatiotemporal Calibration For RGBDs via Continuous-Time Velocity Estimation

Sign in to get full access

or

If you already have an account, we'll log you in

Overview

  • Presents a novel method called iKalibr-RGBD for spatiotemporal calibration of RGBD (RGB-Depth) cameras and inertial measurement units (IMUs)
  • Uses continuous-time optimization to estimate the relative pose and temporal offsets between the sensors, without requiring any special calibration targets
  • Claims to be more accurate and robust than existing target-based calibration techniques

Plain English Explanation

iKalibr-RGBD is a new approach for aligning the data from RGBD cameras and inertial measurement units (IMUs). These types of sensor systems are commonly used in robotics, augmented reality, and other applications that need to track the 3D position and orientation of objects.

Typically, calibrating these sensor systems requires moving a special calibration target around while recording data. This can be time-consuming and error-prone. iKalibr-RGBD, on the other hand, can perform the calibration without any calibration targets. Instead, it uses the natural motion of the sensors themselves to estimate how they are positioned and timed relative to each other.

The key idea is to model the motion of the sensors over time using a continuous-time optimization approach. This allows the method to be more robust to sudden changes in motion, which can happen in real-world scenarios. The researchers claim that iKalibr-RGBD is more accurate and reliable than existing target-based calibration techniques.

Technical Explanation

The iKalibr-RGBD method uses a continuous-time representation to model the motion of the RGBD camera and IMU sensors. This allows the calibration to be performed without relying on special calibration targets.

The core of the approach is a joint optimization problem that simultaneously estimates the spatial transformation (position and orientation) between the RGBD camera and IMU, as well as the temporal offset between their measurements. This is achieved by modeling the 3D poses and velocities of the sensors over time using smooth spline functions.

The objective function being optimized incorporates several terms:

  • Reprojection error: the discrepancy between observed 3D points and their projections into the RGBD camera
  • Inertial error: the difference between the IMU's measured accelerations/angular velocities and those predicted by the continuous-time motion model
  • Temporal error: the misalignment between the timestamps of RGBD and IMU measurements

By optimizing this objective, iKalibr-RGBD can accurately recover the spatial and temporal relationships between the sensors without requiring any special calibration targets or movements.

Critical Analysis

The iKalibr-RGBD method represents an interesting advance in sensor calibration, as it can achieve accurate results without the need for calibration targets or predefined motion patterns. This is a valuable capability, as setting up and executing traditional calibration procedures can be time-consuming and error-prone.

That said, the paper does not provide a comprehensive evaluation of the method's performance and limitations. The experiments are limited to simulated data and a single real-world dataset, leaving open questions about the robustness of iKalibr-RGBD to different sensor configurations, motion patterns, and real-world conditions.

Additionally, the paper does not discuss potential failure modes or edge cases that could affect the calibration accuracy. For example, it's unclear how the method would handle significant sensor noise, synchronization issues, or non-overlapping fields of view between the RGBD camera and IMU.

Further research and more extensive evaluations would be helpful to better understand the strengths, weaknesses, and applicability of the iKalibr-RGBD approach across a wider range of scenarios.

Conclusion

iKalibr-RGBD presents a novel method for spatiotemporal calibration of RGBD cameras and inertial measurement units. By using continuous-time optimization, it can perform this calibration without relying on special calibration targets or predefined motion patterns.

This target-free approach has the potential to simplify and streamline the calibration process, which is an essential step for many robotics, augmented reality, and computer vision applications. While the initial results are promising, further research is needed to fully understand the method's robustness and limitations across a wider range of real-world scenarios.

Overall, iKalibr-RGBD represents an interesting contribution to the field of sensor calibration, and its continuous-time optimization approach could inspire similar innovations in related areas of computer vision and robotics.



This summary was produced with help from an AI and may contain inaccuracies - check out the links to read the original source documents!

Follow @aimodelsfyi on 𝕏 →

Related Papers

iKalibr-RGBD: Partially-Specialized Target-Free Visual-Inertial Spatiotemporal Calibration For RGBDs via Continuous-Time Velocity Estimation
Total Score

0

iKalibr-RGBD: Partially-Specialized Target-Free Visual-Inertial Spatiotemporal Calibration For RGBDs via Continuous-Time Velocity Estimation

Shuolong Chen, Xingxing Li, Shengyu Li, Yuxuan Zhou

Visual-inertial systems have been widely studied and applied in the last two decades, mainly due to their low cost and power consumption, small footprint, and high availability. Such a trend simultaneously leads to a large amount of visual-inertial calibration methods being presented, as accurate spatiotemporal parameters between sensors are a prerequisite for visual-inertial fusion. In our previous work, i.e., iKalibr, a continuous-time-based visual-inertial calibration method was proposed as a part of one-shot multi-sensor resilient spatiotemporal calibration. While requiring no artificial target brings considerable convenience, computationally expensive pose estimation is demanded in initialization and batch optimization, limiting its availability. Fortunately, this could be vastly improved for the RGBDs with additional depth information, by employing mapping-free ego-velocity estimation instead of mapping-based pose estimation. In this paper, we present the continuous-time ego-velocity estimation-based RGBD-inertial spatiotemporal calibration, termed as iKalibr-RGBD, which is also targetless but computationally efficient. The general pipeline of iKalibr-RGBD is inherited from iKalibr, composed of a rigorous initialization procedure and several continuous-time batch optimizations. The implementation of iKalibr-RGBD is open-sourced at (https://github.com/Unsigned-Long/iKalibr) to benefit the research community.

Read more

9/12/2024

iKalibr: Unified Targetless Spatiotemporal Calibration for Resilient Integrated Inertial Systems
Total Score

0

iKalibr: Unified Targetless Spatiotemporal Calibration for Resilient Integrated Inertial Systems

Shuolong Chen, Xingxing Li, Shengyu Li, Yuxuan Zhou, Xiaoteng Yang

The integrated inertial system, typically integrating an IMU and an exteroceptive sensor such as radar, LiDAR, and camera, has been widely accepted and applied in modern robotic applications for ego-motion estimation, motion control, or autonomous exploration. To improve system accuracy, robustness, and further usability, both multiple and various sensors are generally resiliently integrated, which benefits the system performance regarding failure tolerance, perception capability, and environment compatibility. For such systems, accurate and consistent spatiotemporal calibration is required to maintain a unique spatiotemporal framework for multi-sensor fusion. Considering most existing calibration methods (i) are generally oriented to specific integrated inertial systems, (ii) often only focus on spatial determination, (iii) usually require artificial targets, lacking convenience and usability, we propose iKalibr: a unified targetless spatiotemporal calibration framework for resilient integrated inertial systems, which overcomes the above issues, and enables both accurate and consistent calibration. Altogether four commonly employed sensors are supported in iKalibr currently, namely IMU, radar, LiDAR, and camera. The proposed method starts with a rigorous and efficient dynamic initialization, where all parameters in the estimator would be accurately recovered. Following that, several continuous-time-based batch optimizations would be carried out to refine initialized parameters to global optimal ones. Sufficient real-world experiments were conducted to verify the feasibility and evaluate the calibration performance of iKalibr. The results demonstrate that iKalibr can achieve accurate resilient spatiotemporal calibration. We open-source our implementations at (https://github.com/Unsigned-Long/iKalibr) to benefit the research community.

Read more

7/17/2024

3DGS-Calib: 3D Gaussian Splatting for Multimodal SpatioTemporal Calibration
Total Score

0

New!3DGS-Calib: 3D Gaussian Splatting for Multimodal SpatioTemporal Calibration

Quentin Herau, Moussab Bennehar, Arthur Moreau, Nathan Piasco, Luis Roldao, Dzmitry Tsishkou, Cyrille Migniot, Pascal Vasseur, C'edric Demonceaux

Reliable multimodal sensor fusion algorithms require accurate spatiotemporal calibration. Recently, targetless calibration techniques based on implicit neural representations have proven to provide precise and robust results. Nevertheless, such methods are inherently slow to train given the high computational overhead caused by the large number of sampled points required for volume rendering. With the recent introduction of 3D Gaussian Splatting as a faster alternative to implicit representation methods, we propose to leverage this new rendering approach to achieve faster multi-sensor calibration. We introduce 3DGS-Calib, a new calibration method that relies on the speed and rendering accuracy of 3D Gaussian Splatting to achieve multimodal spatiotemporal calibration that is accurate, robust, and with a substantial speed-up compared to methods relying on implicit neural representations. We demonstrate the superiority of our proposal with experimental results on sequences from KITTI-360, a widely used driving dataset.

Read more

9/19/2024

🌀

Total Score

0

Multi-Visual-Inertial System: Analysis, Calibration and Estimation

Yulin Yang, Patrick Geneva, Guoquan Huang

In this paper, we study state estimation of multi-visual-inertial systems (MVIS) and develop sensor fusion algorithms to optimally fuse an arbitrary number of asynchronous inertial measurement units (IMUs) or gyroscopes and global and(or) rolling shutter cameras. We are especially interested in the full calibration of the associated visual-inertial sensors, including the IMU or camera intrinsics and the IMU-IMU(or camera) spatiotemporal extrinsics as well as the image readout time of rolling-shutter cameras (if used). To this end, we develop a new analytic combined IMU integration with intrinsics-termed ACI3-to preintegrate IMU measurements, which is leveraged to fuse auxiliary IMUs and(or) gyroscopes alongside a base IMU. We model the multi-inertial measurements to include all the necessary inertial intrinsic and IMU-IMU spatiotemporal extrinsic parameters, while leveraging IMU-IMU rigid-body constraints to eliminate the necessity of auxiliary inertial poses and thus reducing computational complexity. By performing observability analysis of MVIS, we prove that the standard four unobservable directions remain - no matter how many inertial sensors are used, and also identify, for the first time, degenerate motions for IMU-IMU spatiotemporal extrinsics and auxiliary inertial intrinsics. In addition to the extensive simulations that validate our analysis and algorithms, we have built our own MVIS sensor rig and collected over 25 real-world datasets to experimentally verify the proposed calibration against the state-of-the-art calibration method such as Kalibr. We show that the proposed MVIS calibration is able to achieve competing accuracy with improved convergence and repeatability, which is open sourced to better benefit the community.

Read more

9/4/2024