iKalibr: Unified Targetless Spatiotemporal Calibration for Resilient Integrated Inertial Systems

Read original: arXiv:2407.11420 - Published 7/17/2024 by Shuolong Chen, Xingxing Li, Shengyu Li, Yuxuan Zhou, Xiaoteng Yang
Total Score

0

iKalibr: Unified Targetless Spatiotemporal Calibration for Resilient Integrated Inertial Systems

Sign in to get full access

or

If you already have an account, we'll log you in

Overview

  • Presents a unified framework for spatiotemporal calibration of integrated inertial systems, called iKalibr
  • Enables targetless calibration of multi-sensor systems like IMUs, LIDARs, and cameras in a continuous-time batch optimization
  • Improves resilience to sensor failures and environmental changes compared to existing methods

Plain English Explanation

iKalibr: Unified Targetless Spatiotemporal Calibration for Resilient Integrated Inertial Systems is a new calibration technique that can align the various sensors in a robotic system, like inertial measurement units (IMUs), LIDARs, and cameras, without requiring special calibration targets. This is important because it makes the calibration process easier and more flexible, allowing the sensors to be recalibrated even in dynamic environments where targets may not be available.

The key innovation is a continuous-time batch optimization framework that can jointly estimate the spatial and temporal relationships between the different sensors. This allows the system to be more resilient to sensor failures or environmental changes that could throw off traditional calibration approaches. The authors demonstrate the effectiveness of iKalibr through experiments on ground robots equipped with IMUs, LIDARs, and cameras.

Technical Explanation

iKalibr presents a unified framework for spatiotemporal calibration of integrated inertial systems, which can jointly estimate the spatial transformations and temporal offsets between multiple sensors like IMUs, LIDARs, and cameras. Unlike previous methods that require special calibration targets, iKalibr uses a continuous-time batch optimization approach to enable targetless calibration.

The core of iKalibr is a factor graph formulation that models the spatiotemporal relationships between the sensors. This allows the calibration to be performed in a holistic manner, improving resilience to sensor failures or environmental changes that could degrade the performance of traditional calibration techniques. The authors also introduce a novel rotation initialization and stepwise refinement method to enhance the convergence of the optimization.

Experiments on ground robots equipped with IMUs, LIDARs, and cameras demonstrate the effectiveness of iKalibr in achieving accurate spatiotemporal calibration without the need for calibration targets. The authors also compare iKalibr to Ultra-Inertial Poser, a state-of-the-art LIDAR-inertial odometry approach, demonstrating the improved resilience and accuracy of their method.

Critical Analysis

The iKalibr framework presented in the paper is a significant advancement in the field of multi-sensor calibration, addressing the limitations of existing approaches that rely on specialized calibration targets. The authors' use of continuous-time batch optimization and their novel initialization and refinement techniques are important contributions that enhance the robustness and effectiveness of the calibration process.

However, the paper does not extensively cover the computational complexity or runtime performance of the iKalibr optimization, which could be an important consideration for real-time applications. Additionally, the experiments are limited to ground robot platforms, and it would be valuable to see how the method performs on other types of robotic systems, such as aerial vehicles or underwater platforms, which may have different sensor configurations and operating environments.

Furthermore, while the authors discuss the resilience of iKalibr to sensor failures and environmental changes, they do not provide a comprehensive analysis of the failure modes or the limits of the method's robustness. It would be helpful to understand the types of sensor failures or environmental conditions that could still challenge the iKalibr approach.

Conclusion

iKalibr presents a powerful and flexible framework for spatiotemporal calibration of integrated inertial systems, enabling accurate and resilient calibration without the need for specialized calibration targets. This is a significant advancement that can facilitate the deployment of multi-sensor robotic systems in a wide range of applications, from autonomous vehicles to search and rescue operations, where adaptability and robustness are crucial. The authors' contributions in continuous-time batch optimization and rotation initialization/refinement are valuable additions to the field of sensor calibration, and their work lays the foundation for further research and development in this area.



This summary was produced with help from an AI and may contain inaccuracies - check out the links to read the original source documents!

Follow @aimodelsfyi on 𝕏 →

Related Papers

iKalibr: Unified Targetless Spatiotemporal Calibration for Resilient Integrated Inertial Systems
Total Score

0

iKalibr: Unified Targetless Spatiotemporal Calibration for Resilient Integrated Inertial Systems

Shuolong Chen, Xingxing Li, Shengyu Li, Yuxuan Zhou, Xiaoteng Yang

The integrated inertial system, typically integrating an IMU and an exteroceptive sensor such as radar, LiDAR, and camera, has been widely accepted and applied in modern robotic applications for ego-motion estimation, motion control, or autonomous exploration. To improve system accuracy, robustness, and further usability, both multiple and various sensors are generally resiliently integrated, which benefits the system performance regarding failure tolerance, perception capability, and environment compatibility. For such systems, accurate and consistent spatiotemporal calibration is required to maintain a unique spatiotemporal framework for multi-sensor fusion. Considering most existing calibration methods (i) are generally oriented to specific integrated inertial systems, (ii) often only focus on spatial determination, (iii) usually require artificial targets, lacking convenience and usability, we propose iKalibr: a unified targetless spatiotemporal calibration framework for resilient integrated inertial systems, which overcomes the above issues, and enables both accurate and consistent calibration. Altogether four commonly employed sensors are supported in iKalibr currently, namely IMU, radar, LiDAR, and camera. The proposed method starts with a rigorous and efficient dynamic initialization, where all parameters in the estimator would be accurately recovered. Following that, several continuous-time-based batch optimizations would be carried out to refine initialized parameters to global optimal ones. Sufficient real-world experiments were conducted to verify the feasibility and evaluate the calibration performance of iKalibr. The results demonstrate that iKalibr can achieve accurate resilient spatiotemporal calibration. We open-source our implementations at (https://github.com/Unsigned-Long/iKalibr) to benefit the research community.

Read more

7/17/2024

iKalibr-RGBD: Partially-Specialized Target-Free Visual-Inertial Spatiotemporal Calibration For RGBDs via Continuous-Time Velocity Estimation
Total Score

0

iKalibr-RGBD: Partially-Specialized Target-Free Visual-Inertial Spatiotemporal Calibration For RGBDs via Continuous-Time Velocity Estimation

Shuolong Chen, Xingxing Li, Shengyu Li, Yuxuan Zhou

Visual-inertial systems have been widely studied and applied in the last two decades, mainly due to their low cost and power consumption, small footprint, and high availability. Such a trend simultaneously leads to a large amount of visual-inertial calibration methods being presented, as accurate spatiotemporal parameters between sensors are a prerequisite for visual-inertial fusion. In our previous work, i.e., iKalibr, a continuous-time-based visual-inertial calibration method was proposed as a part of one-shot multi-sensor resilient spatiotemporal calibration. While requiring no artificial target brings considerable convenience, computationally expensive pose estimation is demanded in initialization and batch optimization, limiting its availability. Fortunately, this could be vastly improved for the RGBDs with additional depth information, by employing mapping-free ego-velocity estimation instead of mapping-based pose estimation. In this paper, we present the continuous-time ego-velocity estimation-based RGBD-inertial spatiotemporal calibration, termed as iKalibr-RGBD, which is also targetless but computationally efficient. The general pipeline of iKalibr-RGBD is inherited from iKalibr, composed of a rigorous initialization procedure and several continuous-time batch optimizations. The implementation of iKalibr-RGBD is open-sourced at (https://github.com/Unsigned-Long/iKalibr) to benefit the research community.

Read more

9/12/2024

🌀

Total Score

0

Multi-Visual-Inertial System: Analysis, Calibration and Estimation

Yulin Yang, Patrick Geneva, Guoquan Huang

In this paper, we study state estimation of multi-visual-inertial systems (MVIS) and develop sensor fusion algorithms to optimally fuse an arbitrary number of asynchronous inertial measurement units (IMUs) or gyroscopes and global and(or) rolling shutter cameras. We are especially interested in the full calibration of the associated visual-inertial sensors, including the IMU or camera intrinsics and the IMU-IMU(or camera) spatiotemporal extrinsics as well as the image readout time of rolling-shutter cameras (if used). To this end, we develop a new analytic combined IMU integration with intrinsics-termed ACI3-to preintegrate IMU measurements, which is leveraged to fuse auxiliary IMUs and(or) gyroscopes alongside a base IMU. We model the multi-inertial measurements to include all the necessary inertial intrinsic and IMU-IMU spatiotemporal extrinsic parameters, while leveraging IMU-IMU rigid-body constraints to eliminate the necessity of auxiliary inertial poses and thus reducing computational complexity. By performing observability analysis of MVIS, we prove that the standard four unobservable directions remain - no matter how many inertial sensors are used, and also identify, for the first time, degenerate motions for IMU-IMU spatiotemporal extrinsics and auxiliary inertial intrinsics. In addition to the extensive simulations that validate our analysis and algorithms, we have built our own MVIS sensor rig and collected over 25 real-world datasets to experimentally verify the proposed calibration against the state-of-the-art calibration method such as Kalibr. We show that the proposed MVIS calibration is able to achieve competing accuracy with improved convergence and repeatability, which is open sourced to better benefit the community.

Read more

9/4/2024

GRIL-Calib: Targetless Ground Robot IMU-LiDAR Extrinsic Calibration Method using Ground Plane Motion Constraints
Total Score

0

GRIL-Calib: Targetless Ground Robot IMU-LiDAR Extrinsic Calibration Method using Ground Plane Motion Constraints

TaeYoung Kim, Gyuhyeon Pak, Euntai Kim

Targetless IMU-LiDAR extrinsic calibration methods are gaining significant attention as the importance of the IMU-LiDAR fusion system increases. Notably, existing calibration methods derive calibration parameters under the assumption that the methods require full motion in all axes. When IMU and LiDAR are mounted on a ground robot the motion of which is restricted to planar motion, existing calibration methods are likely to exhibit degraded performance. To address this issue, we present GRIL-Calib: a novel targetless Ground Robot IMU-LiDAR Calibration method. Our proposed method leverages ground information to compensate for the lack of unrestricted full motion. First, we propose LiDAR Odometry (LO) using ground plane residuals to enhance calibration accuracy. Second, we propose the Ground Plane Motion (GPM) constraint and incorporate it into the optimization for calibration, enabling the determination of full 6-DoF extrinsic parameters, including theoretically unobservable direction. Finally, unlike baseline methods, we formulate the calibration not as sequential two optimizations but as a single optimization (SO) problem, solving all calibration parameters simultaneously and improving accuracy. We validate our GRIL-Calib by applying it to various real-world datasets and comparing its performance with that of existing state-of-the-art methods in terms of accuracy and robustness. Our code is available at https://github.com/Taeyoung96/GRIL-Calib.

Read more

5/27/2024