Imaging transformer for MRI denoising with the SNR unit training: enabling generalization across field-strengths, imaging contrasts, and anatomy

Read original: arXiv:2404.02382 - Published 4/4/2024 by Hui Xue, Sarah Hooper, Azaan Rehman, Iain Pierce, Thomas Treibel, Rhodri Davies, W Patricia Bandettini, Rajiv Ramasawmy, Ahsan Javed, Zheren Zhu and 4 others
Total Score

0

🎯

Sign in to get full access

or

If you already have an account, we'll log you in

Overview

  • MRI signal recovery from noise is crucial for fast acquisition, accurate quantification, and high image quality
  • Past work has used convolutional neural networks (CNNs) with paired low and high-SNR images for training
  • However, obtaining high-SNR data can be difficult in certain applications, making it infeasible to train a new denoising network

Plain English Explanation

Magnetic Resonance Imaging (MRI) is a powerful medical imaging technique that allows doctors to see detailed images of the inside of the body. However, the images can sometimes be noisy, which can make it harder to see important details. Reducing this noise is important for getting high-quality images quickly and accurately measuring things in the images.

Previous research has shown that a type of artificial intelligence called a convolutional neural network can be trained to remove noise from MRI images. This works well when you have lots of example images with both noisy and clean versions. But in some situations, it's difficult to get those clean example images, like when scanning at very high resolutions or with low-power MRI machines. In these cases, training a new denoising network may not be practical.

Technical Explanation

This study aims to improve the ability of denoising models to work well even when the training data doesn't cover all possible MRI settings. The key innovations are:

  1. Training the model using complex MRI images with a fixed noise level (SNR unit training), and adding realistic noise based on the MRI coil's properties.
  2. Developing a new "imaging transformer" (imformer) model architecture that can handle 2D, 3D, and 4D (2D over time) MRI data in a single model.

Through experiments, the researchers show this approach outperforms standard CNN models and allows the denoising model to generalize well across different MRI field strengths, image contrasts, and anatomy.

Critical Analysis

The paper provides a promising approach to improving the versatility of MRI denoising models, which could be very valuable for applications where high-quality training data is scarce. However, the authors do not discuss potential limitations, such as the computational requirements of the imformer model or how the performance might scale with larger or more diverse datasets.

Additionally, while the results demonstrate improved generalization, it would be helpful to see more analysis on the types of artifacts or noise patterns the model is able to effectively remove across different MRI settings. Further research could also explore the clinical implications and potential impact on patient outcomes when using these denoising techniques.

Conclusion

This study presents an innovative approach to enhancing the generalization capabilities of MRI denoising models. By using a novel training scheme and model architecture, the researchers have shown how denoising can be made more robust and applicable across a wider range of MRI acquisition settings. This could unlock new possibilities for faster, more accurate, and higher-quality MRI imaging in clinical practice.



This summary was produced with help from an AI and may contain inaccuracies - check out the links to read the original source documents!

Follow @aimodelsfyi on 𝕏 →

Related Papers

🎯

Total Score

0

Imaging transformer for MRI denoising with the SNR unit training: enabling generalization across field-strengths, imaging contrasts, and anatomy

Hui Xue, Sarah Hooper, Azaan Rehman, Iain Pierce, Thomas Treibel, Rhodri Davies, W Patricia Bandettini, Rajiv Ramasawmy, Ahsan Javed, Zheren Zhu, Yang Yang, James Moon, Adrienne Campbell, Peter Kellman

The ability to recover MRI signal from noise is key to achieve fast acquisition, accurate quantification, and high image quality. Past work has shown convolutional neural networks can be used with abundant and paired low and high-SNR images for training. However, for applications where high-SNR data is difficult to produce at scale (e.g. with aggressive acceleration, high resolution, or low field strength), training a new denoising network using a large quantity of high-SNR images can be infeasible. In this study, we overcome this limitation by improving the generalization of denoising models, enabling application to many settings beyond what appears in the training data. Specifically, we a) develop a training scheme that uses complex MRIs reconstructed in the SNR units (i.e., the images have a fixed noise level, SNR unit training) and augments images with realistic noise based on coil g-factor, and b) develop a novel imaging transformer (imformer) to handle 2D, 2D+T, and 3D MRIs in one model architecture. Through empirical evaluation, we show this combination improves performance compared to CNN models and improves generalization, enabling a denoising model to be used across field-strengths, image contrasts, and anatomy.

Read more

4/4/2024

📈

Total Score

0

Advancing low-field MRI with a universal denoising imaging transformer: Towards fast and high-quality imaging

Zheren Zhu, Azaan Rehman, Xiaozhi Cao, Congyu Liao, Yoo Jin Lee, Michael Ohliger, Hui Xue, Yang Yang

Recent developments in low-field (LF) magnetic resonance imaging (MRI) systems present remarkable opportunities for affordable and widespread MRI access. A robust denoising method to overcome the intrinsic low signal-noise-ratio (SNR) barrier is critical to the success of LF MRI. However, current data-driven MRI denoising methods predominantly handle magnitude images and rely on customized models with constrained data diversity and quantity, which exhibit limited generalizability in clinical applications across diverse MRI systems, pulse sequences, and organs. In this study, we present ImT-MRD: a complex-valued imaging transformer trained on a vast number of clinical MRI scans aiming at universal MR denoising at LF systems. Compared with averaging multiple-repeated scans for higher image SNR, the model obtains better image quality from fewer repetitions, demonstrating its capability for accelerating scans under various clinical settings. Moreover, with its complex-valued image input, the model can denoise intermediate results before advanced post-processing and prepare high-quality data for further MRI research. By delivering universal and accurate denoising across clinical and research tasks, our model holds great promise to expedite the evolution of LF MRI for accessible and equal biomedical applications.

Read more

5/1/2024

🧠

Total Score

0

Enhancing convolutional neural network generalizability via low-rank weight approximation

Chenyin Gao, Shu Yang, Anru R. Zhang

Noise is ubiquitous during image acquisition. Sufficient denoising is often an important first step for image processing. In recent decades, deep neural networks (DNNs) have been widely used for image denoising. Most DNN-based image denoising methods require a large-scale dataset or focus on supervised settings, in which single/pairs of clean images or a set of noisy images are required. This poses a significant burden on the image acquisition process. Moreover, denoisers trained on datasets of limited scale may incur over-fitting. To mitigate these issues, we introduce a new self-supervised framework for image denoising based on the Tucker low-rank tensor approximation. With the proposed design, we are able to characterize our denoiser with fewer parameters and train it based on a single image, which considerably improves the model's generalizability and reduces the cost of data acquisition. Extensive experiments on both synthetic and real-world noisy images have been conducted. Empirical results show that our proposed method outperforms existing non-learning-based methods (e.g., low-pass filter, non-local mean), single-image unsupervised denoisers (e.g., DIP, NN+BM3D) evaluated on both in-sample and out-sample datasets. The proposed method even achieves comparable performances with some supervised methods (e.g., DnCNN).

Read more

8/2/2024

🖼️

Total Score

0

Magnetic Resonance Image Processing Transformer for General Reconstruction

Guoyao Shen, Mengyu Li, Stephan Anderson, Chad W. Farris, Xin Zhang

Purpose: To develop and evaluate a deep learning model for general accelerated MRI reconstruction. Materials and Methods: This retrospective study built a magnetic resonance image processing transformer (MR-IPT) which includes multi-head-tails and a single shared window transformer main body. Three mutations of MR-IPT with different transformer structures were implemented to guide the design of our MR-IPT model. Pre-trained on the MRI set of RadImageNet including 672675 images with multiple anatomy categories, the model was further migrated and evaluated on fastMRI knee dataset with 25012 images for downstream reconstruction tasks. We performed comparison studies with three CNN-based conventional networks in zero- and few-shot learning scenarios. Transfer learning process was conducted on both MR-IPT and CNN networks to further validate the generalizability of MR-IPT. To study the model performance stability, we evaluated our model with various downstream dataset sizes ranging from 10 to 2500 images. Result: The MR-IPT model provided superior performance in multiple downstream tasks compared to conventional CNN networks. MR-IPT achieved a PSNR/SSIM of 26.521/0.6102 (4-fold) and 24.861/0.4996 (8-fold) in 10-epoch learning, surpassing UNet128 at 25.056/0.5832 (4-fold) and 22.984/0.4637 (8-fold). With the same large-scale pre-training, MR-IPT provided a 5% performance boost compared to UNet128 in zero-shot learning in 8-fold and 3% in 4-fold. Conclusion: MR-IPT framework benefits from its transformer-based structure and large-scale pre-training and can serve as a solid backbone in other downstream tasks with zero- and few-shot learning.

Read more

5/27/2024