  • Affordable and widespread access to magnetic resonance imaging (MRI) is enabled by the development of low-field (LF) MRI systems.
  • A key challenge with LF MRI is the inherently low signal-to-noise ratio (SNR), which requires robust denoising methods.
  • Current data-driven MRI denoising approaches are limited in their generalizability across diverse MRI systems, pulse sequences, and organs.

Plain English Explanation

MRI is a widely used medical imaging technique, but the equipment can be costly and not accessible to everyone. Recent advancements in low-field MRI systems have made it possible to create more affordable and widely available MRI scanners. However, one of the drawbacks of these low-field systems is that the images they produce have a lower signal-to-noise ratio (SNR), meaning the useful signal is weaker compared to the background noise.

To overcome this issue, the researchers developed a denoising method called ImT-MRD, which is a complex-valued imaging transformer model. This model was trained on a large dataset of clinical MRI scans from various systems, pulse sequences, and organs, with the goal of being able to denoise images from any LF MRI system, regardless of the specific equipment or scanning protocol used.

The key advantage of this approach is that it can produce higher-quality images from fewer repeated scans, compared to simply averaging multiple scans to improve the SNR. This could help accelerate the scanning process and make LF MRI more practical for clinical use. Additionally, the model's ability to work with complex-valued image data means it can improve the quality of intermediate results before advanced post-processing, which could benefit further MRI research.

Technical Explanation

The researchers present ImT-MRD, a complex-valued imaging transformer model trained on a vast number of clinical MRI scans, aimed at universal MR denoising for low-field (LF) MRI systems. Unlike previous data-driven MRI denoising methods that predominantly handle magnitude images and rely on customized models with limited data diversity and quantity, ImT-MRD can handle complex-valued image inputs and is trained on a large, diverse dataset to achieve better generalizability across different MRI systems, pulse sequences, and organs.

Compared to simply averaging multiple repeated scans to increase the signal-to-noise ratio (SNR), the ImT-MRD model is able to produce better quality images from fewer repetitions, demonstrating its capability for accelerating scans under various clinical settings. Moreover, the complex-valued nature of the model's input and output allows it to denoise intermediate results before advanced post-processing, which can benefit further MRI research and development, as described in Representing Noisy Image without Denoising and CT Image Denoising Method Based on Residual Encoder-Decoder.

The researchers leverage the powerful Uformer architecture, which combines the strengths of U-Net and transformer models, to design the ImT-MRD network. This allows the model to effectively capture both local and global features in the complex-valued MRI data, leading to robust and accurate denoising performance.

Critical Analysis

The researchers acknowledge that while the ImT-MRD model demonstrates impressive performance in denoising LF MRI images, there are still some limitations and areas for further research. For example, the model was trained on a diverse dataset, but it may not have encountered all possible variations in MRI systems, pulse sequences, and organ types that could be encountered in real-world clinical settings. Additionally, the researchers did not extensively explore the model's performance on specific clinical tasks or its ability to handle various types of noise and artifacts that may arise in LF MRI.

Furthermore, the researchers do not discuss the computational and memory requirements of the ImT-MRD model, which could be an important consideration for its practical deployment in clinical environments with limited computing resources. It would also be valuable to see a more in-depth comparison of the ImT-MRD model's performance against other state-of-the-art MRI denoising approaches, as well as an analysis of its robustness to different types of noise and artifacts.

Conclusion

The development of ImT-MRD, a complex-valued imaging transformer model for universal MRI denoising in low-field systems, represents a significant step towards affordable and accessible MRI technology. By leveraging a large and diverse dataset of clinical MRI scans, the model demonstrates the ability to produce high-quality images from fewer repeated scans, potentially accelerating the scanning process and enabling wider adoption of LF MRI. The complex-valued nature of the model's input and output also opens up new avenues for further MRI research and development, as the denoised intermediate results can be used as a foundation for advanced post-processing and analysis. While the study has some limitations, the promising results suggest that this approach holds great promise for revolutionizing the accessibility and impact of MRI in biomedical applications.



This summary was produced with help from an AI and may contain inaccuracies - check out the links to read the original source documents!

Follow @aimodelsfyi on 𝕏 →

Related Papers

📈

Total Score

0

Advancing low-field MRI with a universal denoising imaging transformer: Towards fast and high-quality imaging

Zheren Zhu, Azaan Rehman, Xiaozhi Cao, Congyu Liao, Yoo Jin Lee, Michael Ohliger, Hui Xue, Yang Yang

Recent developments in low-field (LF) magnetic resonance imaging (MRI) systems present remarkable opportunities for affordable and widespread MRI access. A robust denoising method to overcome the intrinsic low signal-noise-ratio (SNR) barrier is critical to the success of LF MRI. However, current data-driven MRI denoising methods predominantly handle magnitude images and rely on customized models with constrained data diversity and quantity, which exhibit limited generalizability in clinical applications across diverse MRI systems, pulse sequences, and organs. In this study, we present ImT-MRD: a complex-valued imaging transformer trained on a vast number of clinical MRI scans aiming at universal MR denoising at LF systems. Compared with averaging multiple-repeated scans for higher image SNR, the model obtains better image quality from fewer repetitions, demonstrating its capability for accelerating scans under various clinical settings. Moreover, with its complex-valued image input, the model can denoise intermediate results before advanced post-processing and prepare high-quality data for further MRI research. By delivering universal and accurate denoising across clinical and research tasks, our model holds great promise to expedite the evolution of LF MRI for accessible and equal biomedical applications.

Read more

5/1/2024

🎯

Total Score

0

Imaging transformer for MRI denoising with the SNR unit training: enabling generalization across field-strengths, imaging contrasts, and anatomy

Hui Xue, Sarah Hooper, Azaan Rehman, Iain Pierce, Thomas Treibel, Rhodri Davies, W Patricia Bandettini, Rajiv Ramasawmy, Ahsan Javed, Zheren Zhu, Yang Yang, James Moon, Adrienne Campbell, Peter Kellman

The ability to recover MRI signal from noise is key to achieve fast acquisition, accurate quantification, and high image quality. Past work has shown convolutional neural networks can be used with abundant and paired low and high-SNR images for training. However, for applications where high-SNR data is difficult to produce at scale (e.g. with aggressive acceleration, high resolution, or low field strength), training a new denoising network using a large quantity of high-SNR images can be infeasible. In this study, we overcome this limitation by improving the generalization of denoising models, enabling application to many settings beyond what appears in the training data. Specifically, we a) develop a training scheme that uses complex MRIs reconstructed in the SNR units (i.e., the images have a fixed noise level, SNR unit training) and augments images with realistic noise based on coil g-factor, and b) develop a novel imaging transformer (imformer) to handle 2D, 2D+T, and 3D MRIs in one model architecture. Through empirical evaluation, we show this combination improves performance compared to CNN models and improves generalization, enabling a denoising model to be used across field-strengths, image contrasts, and anatomy.

Read more

4/4/2024

💬

Total Score

0

Cross-domain Denoising for Low-dose Multi-frame Spiral Computed Tomography

Yucheng Lu, Zhixin Xu, Moon Hyung Choi, Jimin Kim, Seung-Won Jung

Computed tomography (CT) has been used worldwide as a non-invasive test to assist in diagnosis. However, the ionizing nature of X-ray exposure raises concerns about potential health risks such as cancer. The desire for lower radiation doses has driven researchers to improve reconstruction quality. Although previous studies on low-dose computed tomography (LDCT) denoising have demonstrated the effectiveness of learning-based methods, most were developed on the simulated data. However, the real-world scenario differs significantly from the simulation domain, especially when using the multi-slice spiral scanner geometry. This paper proposes a two-stage method for the commercially available multi-slice spiral CT scanners that better exploits the complete reconstruction pipeline for LDCT denoising across different domains. Our approach makes good use of the high redundancy of multi-slice projections and the volumetric reconstructions while leveraging the over-smoothing problem in conventional cascaded frameworks caused by aggressive denoising. The dedicated design also provides a more explicit interpretation of the data flow. Extensive experiments on various datasets showed that the proposed method could remove up to 70% of noise without compromised spatial resolution, and subjective evaluations by two experienced radiologists further supported its superior performance against state-of-the-art methods in clinical practice.

Read more

7/1/2024

Complex Image-Generative Diffusion Transformer for Audio Denoising
Total Score

0

Complex Image-Generative Diffusion Transformer for Audio Denoising

Junhui Li, Pu Wang, Jialu Li, Youshan Zhang

The audio denoising technique has captured widespread attention in the deep neural network field. Recently, the audio denoising problem has been converted into an image generation task, and deep learning-based approaches have been applied to tackle this problem. However, its performance is still limited, leaving room for further improvement. In order to enhance audio denoising performance, this paper introduces a complex image-generative diffusion transformer that captures more information from the complex Fourier domain. We explore a novel diffusion transformer by integrating the transformer with a diffusion model. Our proposed model demonstrates the scalability of the transformer and expands the receptive field of sparse attention using attention diffusion. Our work is among the first to utilize diffusion transformers to deal with the image generation task for audio denoising. Extensive experiments on two benchmark datasets demonstrate that our proposed model outperforms state-of-the-art methods.