Implicit Neural Representations for Breathing-compensated Volume Reconstruction in Robotic Ultrasound

Read original: arXiv:2311.04999 - Published 4/4/2024 by Yordanka Velikova, Mohammad Farid Azampour, Walter Simson, Marco Esposito, Nassir Navab
Total Score

0

🧠

Sign in to get full access

or

If you already have an account, we'll log you in

Overview

  • Ultrasound (US) imaging is widely used for diagnosing and monitoring abdominal diseases, but can suffer from inconsistent image acquisition and significant variability between operators.
  • Robotic ultrasound systems have emerged as a potential solution, offering standardized acquisition and the ability to capture 3D data.
  • However, 3D US images of the abdomen can be affected by the patient's breathing motion.
  • This study introduces a method to compensate for breathing motion in 3D US imaging by leveraging implicit neural representations.
  • The proposed approach uses a robotic ultrasound system to enable automated, standardized screenings and yield smoother 3D reconstructions that can enhance disease diagnosis and monitoring, demonstrated for abdominal aorta aneurysms.

Plain English Explanation

Ultrasound imaging is a common tool used by doctors to examine the abdomen and diagnose various medical conditions. However, the quality of the ultrasound images can vary depending on the skill and experience of the person operating the ultrasound machine. This can make it difficult to consistently use ultrasound for widespread screening and monitoring of abdominal diseases.

To address this, researchers have developed robotic ultrasound systems that can automate the process of taking ultrasound images. These systems use robots to position the ultrasound probe and follow a standardized protocol, which helps ensure that the images are of consistent quality. Robotic systems can also capture 3D ultrasound data, which can provide more detailed information about the structures inside the abdomen.

One challenge with 3D ultrasound of the abdomen is that the images can be affected by the patient's breathing. As the patient breathes, the organs in the abdomen move, which can distort the 3D image. To overcome this, the researchers in this study used a technique called implicit neural representations to compensate for the breathing motion. This allows the robotic ultrasound system to capture high-quality 3D images that are less affected by the patient's breathing.

The researchers tested their approach using robotic ultrasound screening for abdominal aortic aneurysms, a condition where the main artery in the abdomen becomes enlarged. Their results show that the proposed method can provide smoother, higher-quality 3D reconstructions of the abdominal anatomy, which could improve the ability to diagnose and monitor this and other abdominal conditions.

Technical Explanation

This study introduces a method to compensate for breathing motion in 3D ultrasound (US) imaging of the abdomen using a robotic US system. The researchers leveraged implicit neural representations to model and correct for the breathing-induced motion in the 3D US data.

The proposed pipeline uses a robotic US system to automate the image acquisition process, capturing standardized 3D US scans of the abdomen. To address the challenge of breathing motion, the researchers employed an implicit neural representation model that learns to map the 3D US data to a continuous, differentiable representation. This allows the model to predict the motion of the abdominal structures due to breathing and compensate for it, resulting in smoother 3D reconstructions.

The effectiveness of the proposed method was evaluated using a representative use case of abdominal aortic aneurysm (AAA) diagnosis and monitoring. The experiments demonstrate that the automated robotic acquisition, combined with the breathing motion compensation, yields 3D US reconstructions with reduced artifacts and enhanced visual quality. This can potentially improve the reliability and interpretability of US-based screening and diagnosis of abdominal conditions.

The researchers also discuss the potential of digital perceptual technologies and data-efficient unsupervised interpolation to further enhance the proposed approach, as well as the robustness of visual-inertial navigation and generic expression-aware volumetric head avatars for medical applications.

Critical Analysis

The proposed method demonstrates a promising approach to address the challenge of breathing motion in 3D US imaging of the abdomen. By leveraging robotic US systems and implicit neural representations, the researchers have introduced a solution that can potentially improve the reliability and interpretability of US-based screening and diagnosis.

One potential limitation of the study is the focus on a single use case of abdominal aortic aneurysm (AAA) diagnosis and monitoring. While AAA is a relevant and clinically important application, evaluating the method's performance on a broader range of abdominal conditions could further validate its generalizability.

Additionally, the study does not provide a direct comparison to other breathing motion compensation techniques, such as those based on external motion tracking or image-based registration. Comparing the proposed method's performance, robustness, and computational efficiency against alternative approaches could help establish its relative strengths and weaknesses.

Further research could also explore the integration of the implicit neural representation-based motion compensation with other digital perceptual technologies and data-efficient unsupervised interpolation techniques to further enhance the robustness and performance of the overall system.

Conclusion

This study introduces a method to compensate for breathing motion in 3D ultrasound imaging of the abdomen, leveraging a robotic ultrasound system and implicit neural representations. The proposed approach enables automated, standardized acquisition of 3D US data and yields smoother reconstructions that can enhance the reliability and interpretability of US-based screening and diagnosis of abdominal conditions, as demonstrated for abdominal aortic aneurysms.

The integration of robotic systems, implicit neural representations, and digital perceptual technologies represents a promising avenue for improving the clinical utility of ultrasound imaging, with the potential to facilitate more widespread and effective screening programs for various abdominal diseases.



This summary was produced with help from an AI and may contain inaccuracies - check out the links to read the original source documents!

Follow @aimodelsfyi on 𝕏 →

Related Papers

🧠

Total Score

0

Implicit Neural Representations for Breathing-compensated Volume Reconstruction in Robotic Ultrasound

Yordanka Velikova, Mohammad Farid Azampour, Walter Simson, Marco Esposito, Nassir Navab

Ultrasound (US) imaging is widely used in diagnosing and staging abdominal diseases due to its lack of non-ionizing radiation and prevalent availability. However, significant inter-operator variability and inconsistent image acquisition hinder the widespread adoption of extensive screening programs. Robotic ultrasound systems have emerged as a promising solution, offering standardized acquisition protocols and the possibility of automated acquisition. Additionally, these systems enable access to 3D data via robotic tracking, enhancing volumetric reconstruction for improved ultrasound interpretation and precise disease diagnosis. However, the interpretability of 3D US reconstruction of abdominal images can be affected by the patient's breathing motion. This study introduces a method to compensate for breathing motion in 3D US compounding by leveraging implicit neural representations. Our approach employs a robotic ultrasound system for automated screenings. To demonstrate the method's effectiveness, we evaluate our proposed method for the diagnosis and monitoring of abdominal aorta aneurysms as a representative use case. Our experiments demonstrate that our proposed pipeline facilitates robust automated robotic acquisition, mitigating artifacts from breathing motion, and yields smoother 3D reconstructions for enhanced screening and medical diagnosis.

Read more

4/4/2024

Autonomous Path Planning for Intercostal Robotic Ultrasound Imaging Using Reinforcement Learning
Total Score

0

Autonomous Path Planning for Intercostal Robotic Ultrasound Imaging Using Reinforcement Learning

Yuan Bi, Cheng Qian, Zhicheng Zhang, Nassir Navab, Zhongliang Jiang

Ultrasound (US) has been widely used in daily clinical practice for screening internal organs and guiding interventions. However, due to the acoustic shadow cast by the subcutaneous rib cage, the US examination for thoracic application is still challenging. To fully cover and reconstruct the region of interest in US for diagnosis, an intercostal scanning path is necessary. To tackle this challenge, we present a reinforcement learning (RL) approach for planning scanning paths between ribs to monitor changes in lesions on internal organs, such as the liver and heart, which are covered by rib cages. Structured anatomical information of the human skeleton is crucial for planning these intercostal paths. To obtain such anatomical insight, an RL agent is trained in a virtual environment constructed using computational tomography (CT) templates with randomly initialized tumors of various shapes and locations. In addition, task-specific state representation and reward functions are introduced to ensure the convergence of the training process while minimizing the effects of acoustic attenuation and shadows during scanning. To validate the effectiveness of the proposed approach, experiments have been carried out on unseen CTs with randomly defined single or multiple scanning targets. The results demonstrate the efficiency of the proposed RL framework in planning non-shadowed US scanning trajectories in areas with limited acoustic access.

Read more

4/16/2024

RapidVol: Rapid Reconstruction of 3D Ultrasound Volumes from Sensorless 2D Scans
Total Score

0

RapidVol: Rapid Reconstruction of 3D Ultrasound Volumes from Sensorless 2D Scans

Mark C. Eid, Pak-Hei Yeung, Madeleine K. Wyburd, Jo~ao F. Henriques, Ana I. L. Namburete

Two-dimensional (2D) freehand ultrasonography is one of the most commonly used medical imaging modalities, particularly in obstetrics and gynaecology. However, it only captures 2D cross-sectional views of inherently 3D anatomies, losing valuable contextual information. As an alternative to requiring costly and complex 3D ultrasound scanners, 3D volumes can be constructed from 2D scans using machine learning. However this usually requires long computational time. Here, we propose RapidVol: a neural representation framework to speed up slice-to-volume ultrasound reconstruction. We use tensor-rank decomposition, to decompose the typical 3D volume into sets of tri-planes, and store those instead, as well as a small neural network. A set of 2D ultrasound scans, with their ground truth (or estimated) 3D position and orientation (pose) is all that is required to form a complete 3D reconstruction. Reconstructions are formed from real fetal brain scans, and then evaluated by requesting novel cross-sectional views. When compared to prior approaches based on fully implicit representation (e.g. neural radiance fields), our method is over 3x quicker, 46% more accurate, and if given inaccurate poses is more robust. Further speed-up is also possible by reconstructing from a structural prior rather than from scratch.

Read more

4/17/2024

🔗

Total Score

0

Guiding the Last Centimeter: Novel Anatomy-Aware Probe Servoing for Standardized Imaging Plane Navigation in Robotic Lung Ultrasound

Xihan Ma, Mingjie Zeng, Jeffrey C. Hill, Beatrice Hoffmann, Ziming Zhang, Haichong K. Zhang

Navigating the ultrasound (US) probe to the standardized imaging plane (SIP) for image acquisition is a critical but operator-dependent task in conventional freehand diagnostic US. Robotic US systems (RUSS) offer the potential to enhance imaging consistency by leveraging real-time US image feedback to optimize the probe pose, thereby reducing reliance on operator expertise. However, determining the proper approach to extracting generalizable features from the US images for probe pose adjustment remain challenging. In this work, we propose a SIP navigation framework for RUSS, exemplified in the context of robotic lung ultrasound (LUS). This framework facilitates automatic probe adjustment when in proximity to the SIP. This is achieved by explicitly extracting multiple anatomical features presented in real-time LUS images and performing non-patient-specific template matching to generate probe motion towards the SIP using image-based visual servoing (IBVS). This framework is further integrated with the active-sensing end-effector (A-SEE), a customized robot end-effector that leverages patient external body geometry to maintain optimal probe alignment with the contact surface, thus preserving US signal quality throughout the navigation. The proposed approach ensures procedural interpretability and inter-patient adaptability. Validation is conducted through anatomy-mimicking phantom and in-vivo evaluations involving five human subjects. The results show the framework's high navigation precision with the probe correctly located at the SIP for all cases, exhibiting positioning error of under 2 mm in translation and under 2 degree in rotation. These results demonstrate the navigation process's capability to accomondate anatomical variations among patients.

Read more