Influence of Motion Restrictions in an Ankle Exoskeleton on Gait Kinematics and Stability in Straight Walking

Read original: arXiv:2406.06054 - Published 6/11/2024 by Miha Dezman, Charlotte Marquardt, Adnan Ugur, Tamim Asfour
Total Score

0

Influence of Motion Restrictions in an Ankle Exoskeleton on Gait Kinematics and Stability in Straight Walking

Sign in to get full access

or

If you already have an account, we'll log you in

Overview

  • This paper explores the influence of motion restrictions in an ankle exoskeleton on gait kinematics and stability during straight walking.
  • The researchers investigated how different levels of ankle motion restriction affect the user's walking pattern and balance.
  • The study involved experiments with human participants wearing an ankle exoskeleton with varying degrees of motion restriction.

Plain English Explanation

Ankle exoskeletons are robotic devices that can be worn around the ankle to provide extra support and assistance during walking. However, these exoskeletons may also limit the natural range of motion of the ankle joint, which could impact a person's gait and balance.

In this study, the researchers looked at how different levels of ankle motion restriction in an exoskeleton affected the way people walked and maintained their stability. They had participants wear an ankle exoskeleton that could be adjusted to restrict the ankle's range of motion to varying degrees, and then measured things like the participants' joint angles, walking speed, and balance during straight walking.

The goal was to understand how much ankle motion restriction is optimal - enough to provide support, but not so much that it significantly disrupts the natural walking pattern and makes it harder for the person to keep their balance. This information could help designers create better, more user-friendly ankle exoskeletons in the future.

Technical Explanation

The researchers conducted experiments with 10 healthy participants to investigate the influence of ankle motion restrictions in an exoskeleton on gait kinematics and stability during straight walking. The participants wore an ankle exoskeleton with adjustable dorsiflexion and plantarflexion restrictions, allowing the researchers to test three different levels of motion restriction.

During the walking trials, the researchers measured various gait parameters, including joint angles, walking speed, and measures of dynamic stability such as the margin of stability. They compared the results across the three restriction conditions to assess the impact of the exoskeleton on the participants' natural walking patterns and balance.

The findings showed that increasing the level of ankle motion restriction led to reductions in peak ankle joint angles and walking speed. Additionally, the participants exhibited decreased dynamic stability, as indicated by a smaller margin of stability, when the exoskeleton imposed greater motion restrictions.

These results suggest that there is a tradeoff between the amount of support provided by an ankle exoskeleton and the disruption to natural gait and balance. The researchers conclude that this information can inform the design of ankle exoskeletons to strike a balance between assistance and preserving the user's normal walking function.

Critical Analysis

The study provides valuable insights into the design considerations for ankle exoskeletons, highlighting the importance of carefully balancing the level of motion restriction with the preservation of natural gait and stability. However, the researchers acknowledge several limitations of the work.

First, the experiment only involved straight-line walking, whereas real-world walking often involves more complex maneuvers and terrain. The impact of ankle motion restrictions may be different in more challenging walking scenarios.

Additionally, the study only looked at immediate, short-term effects of the exoskeleton. It is unclear how users might adapt to the restrictions over longer periods of use, and whether any negative impacts on gait and stability could be mitigated through training or other adjustments.

Further research is needed to explore the long-term effects of ankle exoskeletons, as well as their performance in more realistic walking conditions. Investigating the optimal level of motion restriction for different user populations and activities would also help refine the design of these assistive devices.

Conclusion

This study provides important insights into the design considerations for ankle exoskeletons, highlighting the need to balance the level of motion restriction with the preservation of natural gait and stability. The findings suggest that excessive ankle motion restrictions can disrupt walking patterns and reduce dynamic stability, which could negatively impact the user's overall mobility and safety.

By understanding these tradeoffs, designers can work to develop more user-friendly ankle exoskeletons that provide the necessary support while allowing for a more natural and stable walking experience. This research represents an important step towards creating assistive technologies that can seamlessly integrate with the user's natural movements and enhance their overall mobility and independence.



This summary was produced with help from an AI and may contain inaccuracies - check out the links to read the original source documents!

Follow @aimodelsfyi on 𝕏 →

Related Papers

Influence of Motion Restrictions in an Ankle Exoskeleton on Gait Kinematics and Stability in Straight Walking
Total Score

0

Influence of Motion Restrictions in an Ankle Exoskeleton on Gait Kinematics and Stability in Straight Walking

Miha Dezman, Charlotte Marquardt, Adnan Ugur, Tamim Asfour

Exoskeleton devices impose kinematic constraints on a user's motion and affect their stability due to added mass but also due to the simplified mechanical design. This paper investigates how these constraints resulting from simplified mechanical designs impact the gait kinematics and stability of users by wearing an ankle exoskeleton with changeable degree of freedom (DoF). The exoskeleton used in this paper allows one, two, or three DoF at the ankle, simulating different levels of mechanical complexity. This effect was evaluated in a pilot study consisting of six participants walking on a straight path. The results show that increasing the exoskeleton DoF results in an improvement of several metrics, including kinematics and gait parameters. The transition from 1 DoF to 2 DoF is shown to have a larger effect than the transition from 2 DoF to 3 DoF for an ankle exoskeleton. However, an exoskeleton with 3 DoF at the ankle featured the best results. Increasing the number of DoF resulted in stability values closer the values when walking without the exoskeleton, despite the added weight of the exoskeleton.

Read more

6/11/2024

Ankle Exoskeletons May Hinder Standing Balance in Simple Models of Older and Younger Adults
Total Score

0

Ankle Exoskeletons May Hinder Standing Balance in Simple Models of Older and Younger Adults

Daphna Raz, Varun Joshi, Brian R. Umberger, Necmiye Ozay

Humans rely on ankle torque to maintain standing balance, particularly in the presence of small to moderate perturbations. Reductions in maximum torque (MT) production and maximum rate of torque development (MRTD) occur at the ankle with age, diminishing stability. Ankle exoskeletons are powered orthotic devices that may assist older adults by compensating for reduced muscle force and power production capabilities. They may also be able to assist with ankle strategies used for balance. However, no studies have investigated the effect of such devices on balance in older adults. Here, we model the effect ankle exoskeletons have on stability in physics-based models of healthy young and old adults, focusing on the mitigation of age-related deficits such as reduced MT and MRTD. We show that an ankle exoskeleton moderately reduces feasible stability boundaries in users who have full ankle strength. For individuals with age-related deficits, there is a trade-off. While exoskeletons augment stability in low velocity conditions, they reduce stability in some high velocity conditions. Our results suggest that well-established control strategies must still be experimentally validated in older adults.

Read more

8/16/2024

Modelling, Design Optimization and Prototype development of Knee Exoskeleton
Total Score

0

Modelling, Design Optimization and Prototype development of Knee Exoskeleton

Shashank Mani Gautam, Ekta Singla, Ashish Singla

This study focuses on enhancing the design of an existing knee exoskeleton by addressing limitations in the range of motion (ROM) during Sit-to-Stand (STS) motions. While current knee exoskeletons emphasize toughness and rehabilitation, their closed-loop mechanisms hinder optimal ROM, which is crucial for effective rehabilitation. This research aims to optimize the exoskeleton design to achieve the necessary ROM, improving its functionality in rehabilitation. This can be achieved by utilizing kinematic modeling and formulation, the existing design was represented in the non-linear and non-convex mathematical functions. Optimization techniques, considering constraints based on human leg measurements, were applied to determine the best dimensions for the exoskeleton. This resulted in a significant increase in ROM compared to existing models. A MATLAB program was developed to compare the ROM of the optimized exoskeleton with the original design. To validate the practicality of the optimized design, analysis was conducted using a mannequin with average human dimensions, followed by constructing a cardboard dummy model to confirm simulation results. The STS motion of an average human was captured using a camera and TRACKER software, and the motion was compared with that of the dummy model to identify any misalignments between the human and exoskeleton knee joints. Furthermore, a prototype of the knee joint exoskeleton is being developed to further investigate misalignments and improve the design. Future work includes the use of EMG sensors for more detailed analysis and better results.

Read more

9/5/2024

Development and Validation of a Modular Sensor-Based System for Gait Analysis and Control in Lower-Limb Exoskeletons
Total Score

0

Development and Validation of a Modular Sensor-Based System for Gait Analysis and Control in Lower-Limb Exoskeletons

Giorgos Marinou, Ibrahima Kourouma, Katja Mombaur

With rapid advancements in exoskeleton hardware technologies, successful assessment and accurate control remain challenging. This study introduces a modular sensor-based system to enhance biomechanical evaluation and control in lower-limb exoskeletons, utilizing advanced sensor technologies and fuzzy logic. We aim to surpass the limitations of current biomechanical evaluation methods confined to laboratories and to address the high costs and complexity of exoskeleton control systems. The system integrates inertial measurement units, force-sensitive resistors, and load cells into instrumented crutches and 3D-printed insoles. These components function both independently and collectively to capture comprehensive biomechanical data, including the anteroposterior center of pressure and crutch ground reaction forces. This data is processed through a central unit using fuzzy logic algorithms for real-time gait phase estimation and exoskeleton control. Validation experiments with three participants, benchmarked against gold-standard motion capture and force plate technologies, demonstrate our system's capability for reliable gait phase detection and precise biomechanical measurements. By offering our designs open-source and integrating cost-effective technologies, this study advances wearable robotics and promotes broader innovation and adoption in exoskeleton research.

Read more

9/4/2024