Modelling, Design Optimization and Prototype development of Knee Exoskeleton

Read original: arXiv:2409.02635 - Published 9/5/2024 by Shashank Mani Gautam, Ekta Singla, Ashish Singla
Total Score

0

Modelling, Design Optimization and Prototype development of Knee Exoskeleton

Sign in to get full access

or

If you already have an account, we'll log you in

Overview

  • This paper focuses on the modelling, design optimization, and prototype development of a knee exoskeleton.
  • The researchers aim to create an exoskeleton that can assist and augment human knee function.
  • The paper covers the architecture of existing knee joint exoskeletons, the design and optimization process, and the development of a prototype.

Plain English Explanation

The researchers in this paper are working on creating a knee exoskeleton - a wearable device that can help support and enhance a person's knee function. Knee exoskeletons are a type of assistive technology that can be worn on the legs to provide additional strength and stability for the knees.

In the paper, the team first reviews the architecture of existing knee exoskeletons to understand the current state of the technology. They then go through the process of designing and optimizing a new knee exoskeleton, taking into account factors like weight, comfort, and functionality.

Finally, the researchers build a prototype of their optimized knee exoskeleton design and test it. The goal is to create an exoskeleton that can effectively assist and augment a person's knee movements and provide support where needed.

Technical Explanation

The paper begins by reviewing the architecture of existing knee joint exoskeletons. This provides the researchers with a baseline understanding of the current state of the technology and the key design considerations.

The team then goes through the process of designing and optimizing a new knee exoskeleton. This involves modeling the human knee joint and its range of motion, as well as considering factors like weight, comfort, and energy efficiency. The researchers use computational optimization techniques to arrive at an optimal design.

Finally, the researchers develop a prototype of their optimized knee exoskeleton design and test its performance. This allows them to validate the effectiveness of their approach and identify any areas for further refinement.

Critical Analysis

The paper provides a comprehensive overview of the design and development process for a knee exoskeleton, but it does not delve deeply into the limitations or potential issues with the technology. For example, the researchers do not discuss the long-term durability of the exoskeleton or the potential for user discomfort or skin irritation over extended periods of use.

Additionally, the paper does not address the cost of manufacturing and deploying such a device, which could be a significant barrier to its widespread adoption. Further research is needed to explore these practical considerations and ensure the viability of knee exoskeletons in real-world applications.

Conclusion

This paper presents a detailed approach to the modelling, design optimization, and prototype development of a knee exoskeleton. The researchers have taken a systematic and methodical approach to creating an assistive device that can enhance human knee function.

The insights and techniques described in this paper could have important implications for the field of wearable robotics and the development of advanced assistive technologies that can improve the quality of life for individuals with mobility challenges.



This summary was produced with help from an AI and may contain inaccuracies - check out the links to read the original source documents!

Follow @aimodelsfyi on 𝕏 →

Related Papers

Modelling, Design Optimization and Prototype development of Knee Exoskeleton
Total Score

0

Modelling, Design Optimization and Prototype development of Knee Exoskeleton

Shashank Mani Gautam, Ekta Singla, Ashish Singla

This study focuses on enhancing the design of an existing knee exoskeleton by addressing limitations in the range of motion (ROM) during Sit-to-Stand (STS) motions. While current knee exoskeletons emphasize toughness and rehabilitation, their closed-loop mechanisms hinder optimal ROM, which is crucial for effective rehabilitation. This research aims to optimize the exoskeleton design to achieve the necessary ROM, improving its functionality in rehabilitation. This can be achieved by utilizing kinematic modeling and formulation, the existing design was represented in the non-linear and non-convex mathematical functions. Optimization techniques, considering constraints based on human leg measurements, were applied to determine the best dimensions for the exoskeleton. This resulted in a significant increase in ROM compared to existing models. A MATLAB program was developed to compare the ROM of the optimized exoskeleton with the original design. To validate the practicality of the optimized design, analysis was conducted using a mannequin with average human dimensions, followed by constructing a cardboard dummy model to confirm simulation results. The STS motion of an average human was captured using a camera and TRACKER software, and the motion was compared with that of the dummy model to identify any misalignments between the human and exoskeleton knee joints. Furthermore, a prototype of the knee joint exoskeleton is being developed to further investigate misalignments and improve the design. Future work includes the use of EMG sensors for more detailed analysis and better results.

Read more

9/5/2024

Total Score

0

Exoskeleton-Mediated Physical Human-Human Interaction for a Sit-to-Stand Rehabilitation Task

Lorenzo Vianello, Emek Bar{i}c{s} Kuc{c}uktabak, Matthew Short, Cl'ement Lhoste, Lorenzo Amato, Kevin Lynch, Jose Pons

Sit-to-Stand (StS) is a fundamental daily activity that can be challenging for stroke survivors due to strength, motor control, and proprioception deficits in their lower limbs. Existing therapies involve repetitive StS exercises, but these can be physically demanding for therapists while assistive devices may limit patient participation and hinder motor learning. To address these challenges, this work proposes the use of two lower-limb exoskeletons to mediate physical interaction between therapists and patients during a StS rehabilitative task. This approach offers several advantages, including improved therapist-patient interaction, safety enforcement, and performance quantification. The whole body control of the two exoskeletons transmits online feedback between the two users, but at the same time assists in movement and ensures balance, and thus helping subjects with greater difficulty. In this study we present the architecture of the framework, presenting and discussing some technical choices made in the design.

Read more

5/22/2024

Development and Validation of a Modular Sensor-Based System for Gait Analysis and Control in Lower-Limb Exoskeletons
Total Score

0

Development and Validation of a Modular Sensor-Based System for Gait Analysis and Control in Lower-Limb Exoskeletons

Giorgos Marinou, Ibrahima Kourouma, Katja Mombaur

With rapid advancements in exoskeleton hardware technologies, successful assessment and accurate control remain challenging. This study introduces a modular sensor-based system to enhance biomechanical evaluation and control in lower-limb exoskeletons, utilizing advanced sensor technologies and fuzzy logic. We aim to surpass the limitations of current biomechanical evaluation methods confined to laboratories and to address the high costs and complexity of exoskeleton control systems. The system integrates inertial measurement units, force-sensitive resistors, and load cells into instrumented crutches and 3D-printed insoles. These components function both independently and collectively to capture comprehensive biomechanical data, including the anteroposterior center of pressure and crutch ground reaction forces. This data is processed through a central unit using fuzzy logic algorithms for real-time gait phase estimation and exoskeleton control. Validation experiments with three participants, benchmarked against gold-standard motion capture and force plate technologies, demonstrate our system's capability for reliable gait phase detection and precise biomechanical measurements. By offering our designs open-source and integrating cost-effective technologies, this study advances wearable robotics and promotes broader innovation and adoption in exoskeleton research.

Read more

9/4/2024

Influence of Motion Restrictions in an Ankle Exoskeleton on Gait Kinematics and Stability in Straight Walking
Total Score

0

Influence of Motion Restrictions in an Ankle Exoskeleton on Gait Kinematics and Stability in Straight Walking

Miha Dezman, Charlotte Marquardt, Adnan Ugur, Tamim Asfour

Exoskeleton devices impose kinematic constraints on a user's motion and affect their stability due to added mass but also due to the simplified mechanical design. This paper investigates how these constraints resulting from simplified mechanical designs impact the gait kinematics and stability of users by wearing an ankle exoskeleton with changeable degree of freedom (DoF). The exoskeleton used in this paper allows one, two, or three DoF at the ankle, simulating different levels of mechanical complexity. This effect was evaluated in a pilot study consisting of six participants walking on a straight path. The results show that increasing the exoskeleton DoF results in an improvement of several metrics, including kinematics and gait parameters. The transition from 1 DoF to 2 DoF is shown to have a larger effect than the transition from 2 DoF to 3 DoF for an ankle exoskeleton. However, an exoskeleton with 3 DoF at the ankle featured the best results. Increasing the number of DoF resulted in stability values closer the values when walking without the exoskeleton, despite the added weight of the exoskeleton.

Read more

6/11/2024