  • Researchers explored a new beamforming technique called null subtraction imaging (NSI) to improve the spatial resolution of power Doppler (PD) ultrasound imaging.
  • NSI uses a "null" in the beam pattern to enhance lateral resolution, which can improve PD imaging with and without contrast microbubbles.
  • The study used NSI with singular value decomposition (SVD)-based clutter filters and noise equalization to generate high-resolution PD images.
  • An element sensitivity correction scheme was also proposed as a crucial component of NSI-based PD imaging.

Plain English Explanation

Ultrasound imaging is a widely used medical tool that allows doctors to see inside the body without surgery. One type of ultrasound, called power Doppler (PD), can detect blood flow and is often used to look at small blood vessels. However, the resolution, or level of detail, in PD images is not always high enough to see the smallest vessels.

The researchers in this study looked at a new technique called null subtraction imaging (NSI) as a way to improve the resolution of PD imaging. NSI is a special type of beamforming, which is the process of combining the signals from an array of ultrasound transducers to form an image.

The key idea behind NSI is to use a "null," or gap, in the beam pattern to enhance the lateral, or side-to-side, resolution of the image. This can help reveal smaller blood vessels, both with and without the use of contrast microbubbles (tiny bubbles injected into the bloodstream to improve visibility).

The researchers also combined NSI with other signal processing techniques, like singular value decomposition (SVD) and noise equalization, to further improve the quality of the PD images. Additionally, they proposed a correction method to account for differences in the sensitivity of the individual ultrasound elements.

Technical Explanation

The researchers explored the use of null subtraction imaging (NSI) as an alternative to the standard delay-and-sum (DAS) beamforming technique for improving the spatial resolution of power Doppler (PD) ultrasound imaging.

NSI is a nonlinear beamforming approach that uses three different apodizations, or weighting functions, on receive and then incoherently sums the beamformed envelopes. This technique creates a null, or gap, in the beam pattern that can enhance the lateral resolution, which is particularly beneficial for PD imaging of small blood vessels.

In this study, the researchers used NSI with three types of singular value decomposition (SVD)-based clutter filters and noise equalization to generate high-resolution PD images. They also proposed an element sensitivity correction scheme as a crucial component of the NSI-based PD imaging approach.

The performance of the NSI-based PD imaging was evaluated through a microbubble trace experiment and scanning of a rat brain, both with and without the use of contrast microbubbles. The researchers analyzed the cross-sectional profiles of the microbubble traces and microvessels, calculated the full-width at half-maximum (FWHM) as a quantitative metric, and computed iso-frequency curves to assess the resolution across the field of view.

The results showed up to a six-fold improvement in FWHM and a four-fold improvement in the iso-frequency curve metric for the NSI-based PD microvessel images compared to those generated using the traditional DAS beamforming approach. The researchers were able to achieve a resolvability of 39 μm with the NSI-based PD imaging, while the computational cost was only increased by 40% compared to the DAS-based PD.

Critical Analysis

The researchers have demonstrated a promising approach for improving the spatial resolution of power Doppler ultrasound imaging using null subtraction imaging (NSI). The key strength of this work is the ability to enhance the lateral resolution, which is critical for visualizing small blood vessels, both with and without the use of contrast microbubbles.

However, the study was limited to experiments on a rat brain, and further validation on human subjects would be necessary to assess the real-world applicability of the NSI-based PD imaging technique. Additionally, the researchers did not provide a direct comparison to other advanced beamforming methods, such as multi-polarization superposition beamforming or GPU-accelerated level set evolution, which could also offer significant resolution improvements for transcranial 3D ultrasound localization microscopy.

It would be valuable for future research to explore the performance of NSI-based PD imaging in a wider range of clinical scenarios, such as diagnosing cardiovascular diseases or monitoring tumor vasculature. Additionally, a more comprehensive comparison to other state-of-the-art beamforming techniques could help establish the relative strengths and weaknesses of the NSI approach.

Conclusion

This study presents a novel application of null subtraction imaging (NSI) to enhance the spatial resolution of power Doppler (PD) ultrasound imaging. The researchers demonstrated up to a six-fold improvement in lateral resolution, allowing for the visualization of smaller blood vessels both with and without the use of contrast microbubbles.

The combination of NSI with singular value decomposition (SVD)-based clutter filters, noise equalization, and an element sensitivity correction scheme proved to be a effective approach for generating high-quality PD images. These advances in ultrasound resolution could have significant implications for various medical applications, such as the early detection of cardiovascular diseases or the monitoring of tumor angiogenesis.

While further validation on human subjects is needed, this work represents an important step forward in improving the diagnostic capabilities of power Doppler ultrasound imaging through innovative beamforming techniques.



This summary was produced with help from an AI and may contain inaccuracies - check out the links to read the original source documents!

Follow @aimodelsfyi on 𝕏 →

Related Papers

🤷

Total Score

0

High-resolution Power Doppler Using Null Subtraction Imaging

Zhengchang Kou, Matthew Lowerison, Qi You, Yike Wang, Pengfei Song, Michael L. Oelze

To improve the spatial resolution of power Doppler (PD) imaging, we explored null subtraction imaging (NSI) as an alternative beamforming technique to delay-and-sum (DAS). NSI is a nonlinear beamforming approach that uses three different apodizations on receive and incoherently sums the beamformed envelopes. NSI uses a null in the beam pattern to improve the lateral resolution, which we apply here for improving PD spatial resolution both with and without contrast microbubbles. In this study, we used NSI with three types of singular value decomposition (SVD)-based clutter filters and noise equalization to generate high-resolution PD images. An element sensitivity correction scheme was also proposed as a crucial component of NSI-based PD imaging. First, a microbubble trace experiment was performed to evaluate the resolution improvement of NSI-based PD over traditional DAS-based PD. Then, both contrast-enhanced and contrast free ultrasound PD images were generated from the scan of a rat brain. The cross-sectional profile of the microbubble traces and microvessels were plotted. FWHM was also estimated to provide a quantitative metric. Furthermore, iso-frequency curves were calculated to provide a resolution evaluation metric over the global field of view. Up to six-fold resolution improvement was demonstrated by the FWHM estimate and four-fold resolution improvement was demonstrated by the iso-frequency curve from the NSI-based PD microvessel images compared to microvessel images generated by traditional DAS-based beamforming. A resolvability of 39 um was measured from the NSI-based PD microvessel image. The computational cost of NSI-based PD was only increased by 40 percent over the DAS-based PD.

Read more

4/4/2024

PHOCUS: Physics-Based Deconvolution for Ultrasound Resolution Enhancement
Total Score

0

PHOCUS: Physics-Based Deconvolution for Ultrasound Resolution Enhancement

Felix Duelmer, Walter Simson, Mohammad Farid Azampour, Magdalena Wysocki, Angelos Karlas, Nassir Navab

Ultrasound is widely used in medical diagnostics allowing for accessible and powerful imaging but suffers from resolution limitations due to diffraction and the finite aperture of the imaging system, which restricts diagnostic use. The impulse function of an ultrasound imaging system is called the point spread function (PSF), which is convolved with the spatial distribution of reflectors in the image formation process. Recovering high-resolution reflector distributions by removing image distortions induced by the convolution process improves image clarity and detail. Conventionally, deconvolution techniques attempt to rectify the imaging system's dependent PSF, working directly on the radio-frequency (RF) data. However, RF data is often not readily accessible. Therefore, we introduce a physics-based deconvolution process using a modeled PSF, working directly on the more commonly available B-mode images. By leveraging Implicit Neural Representations (INRs), we learn a continuous mapping from spatial locations to their respective echogenicity values, effectively compensating for the discretized image space. Our contribution consists of a novel methodology for retrieving a continuous echogenicity map directly from a B-mode image through a differentiable physics-based rendering pipeline for ultrasound resolution enhancement. We qualitatively and quantitatively evaluate our approach on synthetic data, demonstrating improvements over traditional methods in metrics such as PSNR and SSIM. Furthermore, we show qualitative enhancements on an ultrasound phantom and an in-vivo acquisition of a carotid artery.

Read more

8/9/2024

Inverse Problem Approach to Aberration Correction for in vivo Transcranial Imaging Based on a Sparse Representation of Contrast-enhanced Ultrasound Data
Total Score

0

Inverse Problem Approach to Aberration Correction for in vivo Transcranial Imaging Based on a Sparse Representation of Contrast-enhanced Ultrasound Data

Paul Xing, Antoine Malescot, Eric Martineau, Ravi Rungta, Jean Provost

Transcranial ultrasound imaging is currently limited by attenuation and aberration induced by the skull. First used in contrast-enhanced ultrasound (CEUS), highly echoic microbubbles allowed for the development of novel imaging modalities such as ultrasound localization microscopy (ULM). Herein, we develop an inverse problem approach to aberration correction (IPAC) that leverages the sparsity of microbubble signals. We propose to use the textit{a priori} knowledge of the medium based upon microbubble localization and wave propagation to build a forward model to link the measured signals directly to the aberration function. A standard least-squares inversion is then used to retrieve the aberration function. We first validated IPAC on simulated data of a vascular network using plane wave as well as divergent wave emissions. We then evaluated the reproducibility of IPAC textit{in vivo} in 5 mouse brains. We showed that aberration correction improved the contrast of CEUS images by 4.6 dB. For ULM images, IPAC yielded sharper vessels, reduced vessel duplications, and improved the resolution from 21.1 $mu$m to 18.3 $mu$m. Aberration correction also improved hemodynamic quantification for velocity magnitude and flow direction.

Read more

5/15/2024

HDN:Hybrid Deep-learning and Non-line-of-sight Reconstruction Framework for Photoacoustic Brain Imaging
Total Score

0

HDN:Hybrid Deep-learning and Non-line-of-sight Reconstruction Framework for Photoacoustic Brain Imaging

Pengcheng Wan, Fan Zhang, Yuting Shen, Xin Shang, Hulin Zhao, Shuangli Liu, Xiaohua Feng, Fei Gao

Photoacoustic imaging (PAI) combines the high contrast of optical imaging with the deep penetration depth of ultrasonic imaging, showing great potential in cerebrovascular disease detection. However, the ultrasonic wave suffers strong attenuation and multi-scattering when it passes through the skull tissue, resulting in the distortion of the collected photoacoustic (PA) signal. In this paper, inspired by the principles of deep learning and non-line-of-sight (NLOS) imaging, we propose an image reconstruction framework named HDN (Hybrid Deep-learning and Non-line-of-sight), which consists of the signal extraction part and difference utilization part. The signal extraction part is used to correct the distorted signal and reconstruct an initial image. The difference utilization part is used to make further use of the signal difference between the distorted signal and corrected signal, reconstructing the residual image between the initial image and the target image. The test results on a PA digital brain simulation dataset show that compared with the traditional delay-and-sum (DAS) method and deep-learning-based method, HDN achieved superior performance in both signal correction and image reconstruction. Specifically for the SSIM index, the HDN reached 0.606 in imaging results, compared to 0.154 for the DAS method and 0.307 for the deep-learning-based method.

Read more

8/23/2024