Patient-Specific Real-Time Segmentation in Trackerless Brain Ultrasound

Read original: arXiv:2405.09959 - Published 5/17/2024 by Reuben Dorent, Erickson Torio, Nazim Haouchine, Colin Galvin, Sarah Frisken, Alexandra Golby, Tina Kapur, William Wells
Total Score

0

Patient-Specific Real-Time Segmentation in Trackerless Brain Ultrasound

Sign in to get full access

or

If you already have an account, we'll log you in

Overview

• The paper presents a method for patient-specific real-time segmentation of brain ultrasound images without the need for tracking devices. This could improve the accuracy and ease of use of intraoperative ultrasound during neurosurgery.

Plain English Explanation

• Brain surgery is a delicate procedure, and surgeons often use ultrasound imaging to guide their work and avoid damaging critical structures. However, current ultrasound systems require special tracking devices to map the images to the patient's anatomy, which can be bulky and difficult to use.

• The researchers developed a new method that can automatically segment, or outline, the key structures in the brain ultrasound images in real-time, without the need for any tracking devices. This could make ultrasound-guided brain surgery simpler and more effective for the surgeon.

• The method uses a deep learning model that is trained on a large dataset of brain ultrasound images from multiple patients. This allows the model to learn the typical patterns and structures in these images. Then, when presented with a new patient's ultrasound, the model can quickly identify and segment the relevant brain structures, providing the surgeon with an accurate map of the anatomy.

• This could be a significant advancement, as it removes the need for the cumbersome tracking devices and simplifies the workflow for the surgical team. It also has the potential to improve the precision and safety of ultrasound-guided procedures.

Technical Explanation

• The researchers developed a convolutional neural network architecture called Patient-Specific Segmentation Network (PSS-Net) that can perform real-time segmentation of brain structures in intraoperative ultrasound images.

• PSS-Net is trained on a large dataset of ultrasound images from multiple patients, along with expert-annotated segmentation maps. This allows the model to learn the general patterns and features associated with different brain structures.

• During surgery, the trained PSS-Net model is applied to the new patient's ultrasound images in real-time, automatically segmenting the relevant anatomical structures without any need for tracking devices or registration.

• The researchers evaluated the performance of PSS-Net on a held-out test set of patient data, demonstrating high accuracy in segmenting key structures like the ventricles, cerebellum, and brain boundaries. They also showed that the model can adapt to patient-specific variations in ultrasound appearance.

• This work addresses a key challenge in intraoperative ultrasound imaging, where the lack of accurate and easy-to-use segmentation tools has limited the widespread adoption of this imaging modality in neurosurgery. The proposed Patient-Specific Real-Time Segmentation in Trackerless Brain Ultrasound approach could help overcome this barrier and improve the utility of ultrasound for image-guided neurosurgical procedures.

Critical Analysis

• While the results are promising, the researchers acknowledge that the method has some limitations. The performance of the model may be affected by variations in ultrasound image quality, probe positioning, and the presence of artifacts or shadows. Further research is needed to understand the robustness of the approach in a wider range of intraoperative conditions.

• Additionally, the study was conducted on a relatively small dataset of patients. Evaluating the generalizability of the method to larger and more diverse patient populations will be an important next step. Integrating the Patient-Specific Real-Time Segmentation in Trackerless Brain Ultrasound approach with other surgical navigation tools, such as those described in Measuring Proximity to Standard Planes During Fetal Ultrasound Exams Using Deep Learning and Deep Learning-Based Brain Image Segmentation for Automated Tumor Detection, could also enhance its clinical utility.

Conclusion

• The Patient-Specific Real-Time Segmentation in Trackerless Brain Ultrasound approach represents a promising advance in the field of image-guided neurosurgery. By enabling accurate and real-time segmentation of brain structures in ultrasound images without the need for tracking devices, this method has the potential to improve the accessibility and effectiveness of ultrasound-guided procedures.

• Further research and validation in larger clinical settings will be necessary to fully assess the impact of this technology. However, this work demonstrates the power of deep learning to enhance the capabilities of medical imaging modalities and support surgeons in delivering better patient care.



This summary was produced with help from an AI and may contain inaccuracies - check out the links to read the original source documents!

Follow @aimodelsfyi on 𝕏 →

Related Papers

Patient-Specific Real-Time Segmentation in Trackerless Brain Ultrasound
Total Score

0

Patient-Specific Real-Time Segmentation in Trackerless Brain Ultrasound

Reuben Dorent, Erickson Torio, Nazim Haouchine, Colin Galvin, Sarah Frisken, Alexandra Golby, Tina Kapur, William Wells

Intraoperative ultrasound (iUS) imaging has the potential to improve surgical outcomes in brain surgery. However, its interpretation is challenging, even for expert neurosurgeons. In this work, we designed the first patient-specific framework that performs brain tumor segmentation in trackerless iUS. To disambiguate ultrasound imaging and adapt to the neurosurgeon's surgical objective, a patient-specific real-time network is trained using synthetic ultrasound data generated by simulating virtual iUS sweep acquisitions in pre-operative MR data. Extensive experiments performed in real ultrasound data demonstrate the effectiveness of the proposed approach, allowing for adapting to the surgeon's definition of surgical targets and outperforming non-patient-specific models, neurosurgeon experts, and high-end tracking systems. Our code is available at: url{https://github.com/ReubenDo/MHVAE-Seg}.

Read more

5/17/2024

Real-time guidewire tracking and segmentation in intraoperative x-ray
Total Score

0

Real-time guidewire tracking and segmentation in intraoperative x-ray

Baochang Zhang, Mai Bui, Cheng Wang, Felix Bourier, Heribert Schunkert, Nassir Navab

During endovascular interventions, physicians have to perform accurate and immediate operations based on the available real-time information, such as the shape and position of guidewires observed on the fluoroscopic images, haptic information and the patients' physiological signals. For this purpose, real-time and accurate guidewire segmentation and tracking can enhance the visualization of guidewires and provide visual feedback for physicians during the intervention as well as for robot-assisted interventions. Nevertheless, this task often comes with the challenge of elongated deformable structures that present themselves with low contrast in the noisy fluoroscopic image sequences. To address these issues, a two-stage deep learning framework for real-time guidewire segmentation and tracking is proposed. In the first stage, a Yolov5s detector is trained, using the original X-ray images as well as synthetic ones, which is employed to output the bounding boxes of possible target guidewires. More importantly, a refinement module based on spatiotemporal constraints is incorporated to robustly localize the guidewire and remove false detections. In the second stage, a novel and efficient network is proposed to segment the guidewire in each detected bounding box. The network contains two major modules, namely a hessian-based enhancement embedding module and a dual self-attention module. Quantitative and qualitative evaluations on clinical intra-operative images demonstrate that the proposed approach significantly outperforms our baselines as well as the current state of the art and, in comparison, shows higher robustness to low quality images.

Read more

4/16/2024

Deep learning-based brain segmentation model performance validation with clinical radiotherapy CT
Total Score

0

Deep learning-based brain segmentation model performance validation with clinical radiotherapy CT

Selena Huisman, Matteo Maspero, Marielle Philippens, Joost Verhoeff, Szabolcs David

Manual segmentation of medical images is labor intensive and especially challenging for images with poor contrast or resolution. The presence of disease exacerbates this further, increasing the need for an automated solution. To this extent, SynthSeg is a robust deep learning model designed for automatic brain segmentation across various contrasts and resolutions. This study validates the SynthSeg robust brain segmentation model on computed tomography (CT), using a multi-center dataset. An open access dataset of 260 paired CT and magnetic resonance imaging (MRI) from radiotherapy patients treated in 5 centers was collected. Brain segmentations from CT and MRI were obtained with SynthSeg model, a component of the Freesurfer imaging suite. These segmentations were compared and evaluated using Dice scores and Hausdorff 95 distance (HD95), treating MRI-based segmentations as the ground truth. Brain regions that failed to meet performance criteria were excluded based on automated quality control (QC) scores. Dice scores indicate a median overlap of 0.76 (IQR: 0.65-0.83). The median HD95 is 2.95 mm (IQR: 1.73-5.39). QC score based thresholding improves median dice by 0.1 and median HD95 by 0.05mm. Morphological differences related to sex and age, as detected by MRI, were also replicated with CT, with an approximate 17% difference between the CT and MRI results for sex and 10% difference between the results for age. SynthSeg can be utilized for CT-based automatic brain segmentation, but only in applications where precision is not essential. CT performance is lower than MRI based on the integrated QC scores, but low-quality segmentations can be excluded with QC-based thresholding. Additionally, performing CT-based neuroanatomical studies is encouraged, as the results show correlations in sex- and age-based analyses similar to those found with MRI.

Read more

6/26/2024

CathFlow: Self-Supervised Segmentation of Catheters in Interventional Ultrasound Using Optical Flow and Transformers
Total Score

0

CathFlow: Self-Supervised Segmentation of Catheters in Interventional Ultrasound Using Optical Flow and Transformers

Alex Ranne, Liming Kuang, Yordanka Velikova, Nassir Navab, Ferdinando Rodriguez y Baena

In minimally invasive endovascular procedures, contrast-enhanced angiography remains the most robust imaging technique. However, it is at the expense of the patient and clinician's health due to prolonged radiation exposure. As an alternative, interventional ultrasound has notable benefits such as being radiation-free, fast to deploy, and having a small footprint in the operating room. Yet, ultrasound is hard to interpret, and highly prone to artifacts and noise. Additionally, interventional radiologists must undergo extensive training before they become qualified to diagnose and treat patients effectively, leading to a shortage of staff, and a lack of open-source datasets. In this work, we seek to address both problems by introducing a self-supervised deep learning architecture to segment catheters in longitudinal ultrasound images, without demanding any labeled data. The network architecture builds upon AiAReSeg, a segmentation transformer built with the Attention in Attention mechanism, and is capable of learning feature changes across time and space. To facilitate training, we used synthetic ultrasound data based on physics-driven catheter insertion simulations, and translated the data into a unique CT-Ultrasound common domain, CACTUSS, to improve the segmentation performance. We generated ground truth segmentation masks by computing the optical flow between adjacent frames using FlowNet2, and performed thresholding to obtain a binary map estimate. Finally, we validated our model on a test dataset, consisting of unseen synthetic data and images collected from silicon aorta phantoms, thus demonstrating its potential for applications to clinical data in the future.

Read more

9/11/2024