Measuring proximity to standard planes during fetal brain ultrasound scanning

Read original: arXiv:2404.07124 - Published 4/11/2024 by Chiara Di Vece, Antonio Cirigliano, Meala Le Lous, Raffaele Napolitano, Anna L. David, Donald Peebles, Pierre Jannin, Francisco Vasconcelos, Danail Stoyanov
Total Score

0

Measuring proximity to standard planes during fetal brain ultrasound scanning

Sign in to get full access

or

If you already have an account, we'll log you in

Overview

  • This paper presents a method for measuring the proximity of fetal brain ultrasound scans to standard reference planes during scanning.
  • The research was supported by the Wellcome/EPSRC Centre for Interventional and Surgical Sciences (WEISS), the Department of Science, Innovation and Technology (DSIT), and the Royal Academy of Engineering.

Plain English Explanation

Ultrasound scans are commonly used to examine the developing brain of a fetus during pregnancy. However, it can be challenging for the sonographer (ultrasound technician) to obtain images that align precisely with the standard reference planes that doctors use to assess fetal brain development. This paper introduces a new approach to help sonographers better understand how close their current scan is to the ideal reference planes.

The key idea is to use machine learning techniques to automatically analyze the ultrasound images and provide feedback to the sonographer about their proximity to the standard reference views. This could help ensure that the scans are of high enough quality to accurately evaluate the fetal brain and detect any potential issues.

Technical Explanation

The researchers developed a semi-supervised learning system to segment the fetal brain in ultrasound images and then estimate the proximity to the standard reference planes.

First, they used a convolutional neural network to perform semantic segmentation of the fetal brain tissue in the ultrasound scans. This allowed them to isolate the brain region and analyze its alignment.

Next, they trained another neural network model to predict the proximity of the current scan to the standard reference planes based on the segmented brain structure. This geometric localization approach allows the system to provide real-time feedback to the sonographer during the scanning process.

The researchers evaluated their method on a dataset of fetal brain ultrasound images, demonstrating that it could accurately estimate the proximity to the standard reference planes. This could be a valuable tool to help sonographers obtain higher quality scans and improve diagnosis of fetal brain development.

Critical Analysis

The paper provides a promising approach for assisting sonographers in obtaining high-quality fetal brain ultrasound scans. By automatically analyzing the scans and providing feedback on alignment with standard reference planes, the system could help ensure that critical brain structures are properly visualized and evaluated.

However, the research is still at an early stage, and there are some potential limitations that could be explored further. For example, the dataset used for training and evaluation was relatively small, so the system's performance on a larger and more diverse set of scans is unclear. Additionally, the paper does not discuss how the system would handle unusual fetal brain anatomy or other challenging scanning conditions that can occur in clinical practice.

Leveraging edge detection in neural networks could be an interesting avenue for future research to improve the segmentation and localization of the fetal brain structure. Incorporating additional clinical context and expert feedback into the system design may also help make it more robust and practical for real-world deployment.

Conclusion

This paper presents a novel approach for assisting sonographers in obtaining fetal brain ultrasound scans that are well-aligned with standard reference planes. By using machine learning techniques to analyze the scans and provide real-time feedback, the system could help improve the quality and consistency of these critical diagnostic images.

While the research is still in the early stages, the proposed method shows promise as a tool to support healthcare professionals in providing the best possible care for pregnant women and their developing babies. As the technology continues to evolve, it may lead to more accurate diagnoses and better outcomes for families.



This summary was produced with help from an AI and may contain inaccuracies - check out the links to read the original source documents!

Follow @aimodelsfyi on 𝕏 →

Related Papers

Measuring proximity to standard planes during fetal brain ultrasound scanning
Total Score

0

Measuring proximity to standard planes during fetal brain ultrasound scanning

Chiara Di Vece, Antonio Cirigliano, Meala Le Lous, Raffaele Napolitano, Anna L. David, Donald Peebles, Pierre Jannin, Francisco Vasconcelos, Danail Stoyanov

This paper introduces a novel pipeline designed to bring ultrasound (US) plane pose estimation closer to clinical use for more effective navigation to the standard planes (SPs) in the fetal brain. We propose a semi-supervised segmentation model utilizing both labeled SPs and unlabeled 3D US volume slices. Our model enables reliable segmentation across a diverse set of fetal brain images. Furthermore, the model incorporates a classification mechanism to identify the fetal brain precisely. Our model not only filters out frames lacking the brain but also generates masks for those containing it, enhancing the relevance of plane pose regression in clinical settings. We focus on fetal brain navigation from 2D ultrasound (US) video analysis and combine this model with a US plane pose regression network to provide sensorless proximity detection to SPs and non-SPs planes; we emphasize the importance of proximity detection to SPs for guiding sonographers, offering a substantial advantage over traditional methods by allowing earlier and more precise adjustments during scanning. We demonstrate the practical applicability of our approach through validation on real fetal scan videos obtained from sonographers of varying expertise levels. Our findings demonstrate the potential of our approach to complement existing fetal US technologies and advance prenatal diagnostic practices.

Read more

4/11/2024

Geometric Transformation Uncertainty for Improving 3D Fetal Brain Pose Prediction from Freehand 2D Ultrasound Videos
Total Score

0

Geometric Transformation Uncertainty for Improving 3D Fetal Brain Pose Prediction from Freehand 2D Ultrasound Videos

Jayroop Ramesh, Nicola K Dinsdale, the INTERGROWTH-21st Consortium, Pak-Hei Yeung, Ana IL Namburete

Accurately localizing two-dimensional (2D) ultrasound (US) fetal brain images in the 3D brain, using minimal computational resources, is an important task for automated US analysis of fetal growth and development. We propose an uncertainty-aware deep learning model for automated 3D plane localization in 2D fetal brain images. Specifically, a multi-head network is trained to jointly regress 3D plane pose from 2D images in terms of different geometric transformations. The model explicitly learns to predict uncertainty to allocate higher weight to inputs with low variances across different transformations to improve performance. Our proposed method, QAERTS, demonstrates superior pose estimation accuracy than the state-of-the-art and most of the uncertainty-based approaches, leading to 9% improvement on plane angle (PA) for localization accuracy, and 8% on normalized cross-correlation (NCC) for sampled image quality. QAERTS also demonstrates efficiency, containing 5$times$ fewer parameters than ensemble-based approach, making it advantageous in resource-constrained settings. In addition, QAERTS proves to be more robust to noise effects observed in freehand US scanning by leveraging rotational discontinuities and explicit output uncertainties.

Read more

7/9/2024

Pose-GuideNet: Automatic Scanning Guidance for Fetal Head Ultrasound from Pose Estimation
Total Score

0

Pose-GuideNet: Automatic Scanning Guidance for Fetal Head Ultrasound from Pose Estimation

Qianhui Men, Xiaoqing Guo, Aris T. Papageorghiou, J. Alison Noble

3D pose estimation from a 2D cross-sectional view enables healthcare professionals to navigate through the 3D space, and such techniques initiate automatic guidance in many image-guided radiology applications. In this work, we investigate how estimating 3D fetal pose from freehand 2D ultrasound scanning can guide a sonographer to locate a head standard plane. Fetal head pose is estimated by the proposed Pose-GuideNet, a novel 2D/3D registration approach to align freehand 2D ultrasound to a 3D anatomical atlas without the acquisition of 3D ultrasound. To facilitate the 2D to 3D cross-dimensional projection, we exploit the prior knowledge in the atlas to align the standard plane frame in a freehand scan. A semantic-aware contrastive-based approach is further proposed to align the frames that are off standard planes based on their anatomical similarity. In the experiment, we enhance the existing assessment of freehand image localization by comparing the transformation of its estimated pose towards standard plane with the corresponding probe motion, which reflects the actual view change in 3D anatomy. Extensive results on two clinical head biometry tasks show that Pose-GuideNet not only accurately predicts pose but also successfully predicts the direction of the fetal head. Evaluations with probe motions further demonstrate the feasibility of adopting Pose-GuideNet for freehand ultrasound-assisted navigation in a sensor-free environment.

Read more

8/20/2024

Automatic facial axes standardization of 3D fetal ultrasound images
Total Score

0

Automatic facial axes standardization of 3D fetal ultrasound images

Antonia Alomar, Ricardo Rubio, Laura Salort, Gerard Albaiges, Antoni Pay`a, Gemma Piella, Federico Sukno

Craniofacial anomalies indicate early developmental disturbances and are usually linked to many genetic syndromes. Early diagnosis is critical, yet ultrasound (US) examinations often fail to identify these features. This study presents an AI-driven tool to assist clinicians in standardizing fetal facial axes/planes in 3D US, reducing sonographer workload and facilitating the facial evaluation. Our network, structured into three blocks-feature extractor, rotation and translation regression, and spatial transformer-processes three orthogonal 2D slices to estimate the necessary transformations for standardizing the facial planes in the 3D US. These transformations are applied to the original 3D US using a differentiable module (the spatial transformer block), yielding a standardized 3D US and the corresponding 2D facial standard planes. The dataset used consists of 1180 fetal facial 3D US images acquired between weeks 20 and 35 of gestation. Results show that our network considerably reduces inter-observer rotation variability in the test set, with a mean geodesic angle difference of 14.12$^{circ}$ $pm$ 18.27$^{circ}$ and an Euclidean angle error of 7.45$^{circ}$ $pm$ 14.88$^{circ}$. These findings demonstrate the network's ability to effectively standardize facial axes, crucial for consistent fetal facial assessments. In conclusion, the proposed network demonstrates potential for improving the consistency and accuracy of fetal facial assessments in clinical settings, facilitating early evaluation of craniofacial anomalies.

Read more

9/5/2024