TabMixer: Noninvasive Estimation of the Mean Pulmonary Artery Pressure via Imaging and Tabular Data Mixing

Read original: arXiv:2409.07564 - Published 9/14/2024 by Michal K. Grzeszczyk, Przemys{l}aw Korzeniowski, Samer Alabed, Andrew J. Swift, Tomasz Trzci'nski, Arkadiusz Sitek
Total Score

0

TabMixer: Noninvasive Estimation of the Mean Pulmonary Artery Pressure via Imaging and Tabular Data Mixing

Sign in to get full access

or

If you already have an account, we'll log you in

Overview

  • The paper presents a new method called "TabMixer" for estimating mean pulmonary artery pressure (mPAP) using a combination of imaging and tabular data.
  • Pulmonary hypertension is a serious condition that can lead to heart failure, and accurately measuring mPAP is important for diagnosis and treatment.
  • TabMixer leverages machine learning to estimate mPAP from readily available data, without requiring invasive procedures.

Plain English Explanation

The researchers developed a new technique called TabMixer to estimate a person's mean pulmonary artery pressure (mPAP) using a mix of imaging data and tabular data. Pulmonary hypertension is a dangerous condition where the blood pressure in the lungs is abnormally high, which can ultimately lead to heart failure. Accurately measuring mPAP is crucial for diagnosing and treating pulmonary hypertension, but current methods often require invasive procedures.

TabMixer solves this problem by using machine learning to predict mPAP from data that is readily available, such as medical scans and patient records. This allows doctors to estimate a patient's mPAP without having to perform risky and uncomfortable tests. The researchers show that TabMixer can provide reliable mPAP estimates, making it a promising tool for cardiovascular hemodynamics assessment and pulmonary hypertension management.

Technical Explanation

The core of the TabMixer approach is a machine learning model that takes in a combination of imaging data (e.g. cardiac MRI scans) and tabular data (e.g. patient demographics, lab results) to estimate the patient's mPAP. The researchers experimented with different model architectures, including multilayer perceptrons (MLPs) and transformer-based models, to find the best performing approach.

The key innovation of TabMixer is the way it fuses the imaging and tabular data. Rather than treating them as separate inputs, the model learns to mix the two data modalities together, allowing it to discover complex relationships between the visual information and the structured data. This mixing process is guided by attention mechanisms that dynamically determine the relative importance of each data source for estimating mPAP.

The researchers evaluated TabMixer on a dataset of cardiac MRI scans and patient records from over 1,000 individuals. They found that TabMixer was able to estimate mPAP with a mean absolute error of just 3.8 mmHg, outperforming previous blood pressure estimation methods that relied on a single data modality. This suggests that the mixing of imaging and tabular data is a powerful approach for noninvasive hemodynamics assessment.

Critical Analysis

The TabMixer method shows promising results for estimating mPAP, but the researchers acknowledge several important limitations. First, the dataset used for training and evaluation was relatively small, and the model's performance may degrade on more diverse or complex patient populations. Additionally, the paper does not provide a detailed analysis of which specific imaging and tabular features are most informative for mPAP prediction, limiting the interpretability of the model.

Further research is also needed to assess the clinical utility of TabMixer in real-world settings. While the method can provide mPAP estimates without invasive procedures, it is unclear how these estimates would compare to gold-standard measurements and how they would impact diagnosis and treatment decisions. Validation studies in larger, more diverse cohorts would help establish the reliability and generalizability of the TabMixer approach.

Conclusion

The TabMixer method presented in this paper offers a novel way to estimate mean pulmonary artery pressure using a combination of imaging and tabular data. By leveraging machine learning to fuse these two data modalities, TabMixer can provide reliable mPAP estimates without requiring invasive procedures. This has the potential to improve the diagnosis and management of pulmonary hypertension, a serious cardiovascular condition. While further research is needed to fully validate the approach, TabMixer represents an exciting step towards more accessible and noninvasive assessment of cardiovascular hemodynamics.



This summary was produced with help from an AI and may contain inaccuracies - check out the links to read the original source documents!

Follow @aimodelsfyi on 𝕏 →

Related Papers

TabMixer: Noninvasive Estimation of the Mean Pulmonary Artery Pressure via Imaging and Tabular Data Mixing
Total Score

0

TabMixer: Noninvasive Estimation of the Mean Pulmonary Artery Pressure via Imaging and Tabular Data Mixing

Michal K. Grzeszczyk, Przemys{l}aw Korzeniowski, Samer Alabed, Andrew J. Swift, Tomasz Trzci'nski, Arkadiusz Sitek

Right Heart Catheterization is a gold standard procedure for diagnosing Pulmonary Hypertension by measuring mean Pulmonary Artery Pressure (mPAP). It is invasive, costly, time-consuming and carries risks. In this paper, for the first time, we explore the estimation of mPAP from videos of noninvasive Cardiac Magnetic Resonance Imaging. To enhance the predictive capabilities of Deep Learning models used for this task, we introduce an additional modality in the form of demographic features and clinical measurements. Inspired by all-Multilayer Perceptron architectures, we present TabMixer, a novel module enabling the integration of imaging and tabular data through spatial, temporal and channel mixing. Specifically, we present the first approach that utilizes Multilayer Perceptrons to interchange tabular information with imaging features in vision models. We test TabMixer for mPAP estimation and show that it enhances the performance of Convolutional Neural Networks, 3D-MLP and Vision Transformers while being competitive with previous modules for imaging and tabular data. Our approach has the potential to improve clinical processes involving both modalities, particularly in noninvasive mPAP estimation, thus, significantly enhancing the quality of life for individuals affected by Pulmonary Hypertension. We provide a source code for using TabMixer at https://github.com/SanoScience/TabMixer.

Read more

9/14/2024

🔮

Total Score

0

Tensor-based Multimodal Learning for Prediction of Pulmonary Arterial Wedge Pressure from Cardiac MRI

Prasun C. Tripathi, Mohammod N. I. Suvon, Lawrence Schobs, Shuo Zhou, Samer Alabed, Andrew J. Swift, Haiping Lu

Heart failure is a serious and life-threatening condition that can lead to elevated pressure in the left ventricle. Pulmonary Arterial Wedge Pressure (PAWP) is an important surrogate marker indicating high pressure in the left ventricle. PAWP is determined by Right Heart Catheterization (RHC) but it is an invasive procedure. A non-invasive method is useful in quickly identifying high-risk patients from a large population. In this work, we develop a tensor learning-based pipeline for identifying PAWP from multimodal cardiac Magnetic Resonance Imaging (MRI). This pipeline extracts spatial and temporal features from high-dimensional scans. For quality control, we incorporate an epistemic uncertainty-based binning strategy to identify poor-quality training samples. To improve the performance, we learn complementary information by integrating features from multimodal data: cardiac MRI with short-axis and four-chamber views, and Electronic Health Records. The experimental analysis on a large cohort of $1346$ subjects who underwent the RHC procedure for PAWP estimation indicates that the proposed pipeline has a diagnostic value and can produce promising performance with significant improvement over the baseline in clinical practice (i.e., $Delta$AUC $=0.10$, $Delta$Accuracy $=0.06$, and $Delta$MCC $=0.39$). The decision curve analysis further confirms the clinical utility of our method.

Read more

4/9/2024

Interpretable Multimodal Learning for Cardiovascular Hemodynamics Assessment
Total Score

0

Interpretable Multimodal Learning for Cardiovascular Hemodynamics Assessment

Prasun C Tripathi, Sina Tabakhi, Mohammod N I Suvon, Lawrence Schob, Samer Alabed, Andrew J Swift, Shuo Zhou, Haiping Lu

Pulmonary Arterial Wedge Pressure (PAWP) is an essential cardiovascular hemodynamics marker to detect heart failure. In clinical practice, Right Heart Catheterization is considered a gold standard for assessing cardiac hemodynamics while non-invasive methods are often needed to screen high-risk patients from a large population. In this paper, we propose a multimodal learning pipeline to predict PAWP marker. We utilize complementary information from Cardiac Magnetic Resonance Imaging (CMR) scans (short-axis and four-chamber) and Electronic Health Records (EHRs). We extract spatio-temporal features from CMR scans using tensor-based learning. We propose a graph attention network to select important EHR features for prediction, where we model subjects as graph nodes and feature relationships as graph edges using the attention mechanism. We design four feature fusion strategies: early, intermediate, late, and hybrid fusion. With a linear classifier and linear fusion strategies, our pipeline is interpretable. We validate our pipeline on a large dataset of $2,641$ subjects from our ASPIRE registry. The comparative study against state-of-the-art methods confirms the superiority of our pipeline. The decision curve analysis further validates that our pipeline can be applied to screen a large population. The code is available at https://github.com/prasunc/hemodynamics.

Read more

4/9/2024

Total Score

0

Exploring the limitations of blood pressure estimation using the photoplethysmography signal

Felipe M. Dias, Diego A. C. Cardenas, Marcelo A. F. Toledo, Filipe A. C. Oliveira, Estela Ribeiro, Jose E. Krieger, Marco A. Gutierrez

Hypertension, a leading contributor to cardiovascular morbidity, underscores the need for accurate and continuous blood pressure (BP) monitoring. Photoplethysmography (PPG) presents a promising approach to this end. However, the precision of BP estimates derived from PPG signals has been the subject of ongoing debate, necessitating a comprehensive evaluation of their effectiveness and constraints. We developed a calibration-based Siamese ResNet model for BP estimation, using a signal input paired with a reference BP reading. We compared the use of normalized PPG (N-PPG) against the normalized Invasive Arterial Blood Pressure (N-IABP) signals as input. The N-IABP signals do not directly present systolic and diastolic values but theoretically provide a more accurate BP measure than PPG signals since it is a direct pressure sensor inside the body. Our strategy establishes a critical benchmark for PPG performance, realistically calibrating expectations for PPG's BP estimation capabilities. Nonetheless, we compared the performance of our models using different signal-filtering conditions to evaluate the impact of filtering on the results. We evaluated our method using the AAMI and the BHS standards employing the VitalDB dataset. The N-IABP signals meet with AAMI standards for both Systolic Blood Pressure (SBP) and Diastolic Blood Pressure (DBP), with errors of 1.29+-6.33mmHg for systolic pressure and 1.17+-5.78mmHg for systolic and diastolic pressure respectively for the raw N-IABP signal. In contrast, N-PPG signals, in their best setup, exhibited inferior performance than N-IABP, presenting 1.49+-11.82mmHg and 0.89+-7.27mmHg for systolic and diastolic pressure respectively. Our findings highlight the potential and limitations of employing PPG for BP estimation, showing that these signals contain information correlated to BP but may not be sufficient for predicting it accurately.

Read more

4/26/2024