Three-dimensional Morphological Reconstruction of Millimeter-Scale Soft Continuum Robots based on Dual-Stereo-Vision

Read original: arXiv:2408.01615 - Published 8/19/2024 by Tian-Ao Ren, Wenyan Liu, Tao Zhang, Lei Zhao, Hongliang Ren, Jiewen Lai
Total Score

0

Three-dimensional Morphological Reconstruction of Millimeter-Scale Soft Continuum Robots based on Dual-Stereo-Vision

Sign in to get full access

or

If you already have an account, we'll log you in

Overview

  • This research paper describes a method for 3D morphological reconstruction of millimeter-scale soft continuum robots using dual stereo vision.
  • The key contributions include a flexible and reliable 3D reconstruction approach, and experimental validation on a soft robotic manipulator.

Plain English Explanation

The paper presents a technique for creating 3D models of small, flexible robotic arms. These types of robots are often used in medical applications, such as performing delicate surgical procedures, where their soft and adaptable nature can be advantageous.

To capture the 3D shape of these tiny robots, the researchers used a system with two pairs of cameras arranged in a stereo configuration. By analyzing the images from these cameras, they were able to reconstruct the 3D structure of the robot with high accuracy, even as it moved and changed shape.

The main benefit of this approach is that it provides a way to precisely measure and track the robot's position and deformation without requiring any markers or sensors to be attached directly to the robot itself. This makes the system more flexible and less intrusive, which is important for many real-world applications.

Technical Explanation

The paper describes a methodology for 3D morphological reconstruction of millimeter-scale soft continuum robots using a dual stereo vision setup. The key elements of their approach include:

  • Stereo Camera Configuration: The system uses two pairs of stereo cameras arranged to provide overlapping views of the robot. This allows for more comprehensive 3D reconstruction compared to a single stereo pair.
  • Flexible Calibration: The researchers developed a flexible calibration procedure to account for inconsistencies in the camera positions and orientations, enabling reliable reconstruction despite these variations.
  • Point Cloud Generation: Images from the stereo camera pairs are processed to generate 3D point clouds representing the robot's surface. Advanced algorithms are used to fuse the data from multiple viewpoints and handle occlusions.
  • Experimental Validation: The reconstruction approach was validated experimentally using a soft robotic manipulator, demonstrating its ability to accurately capture the 3D shape and motion of the robot.

Critical Analysis

The paper provides a comprehensive and well-designed methodology for 3D reconstruction of soft continuum robots. However, a few potential limitations are worth noting:

Despite these minor caveats, the research represents a significant advancement in the field of soft robotics and could have important implications for applications where precise 3D modeling and tracking of these flexible systems is crucial.

Conclusion

This paper presents a novel approach for 3D morphological reconstruction of millimeter-scale soft continuum robots using dual stereo vision. The flexible and reliable reconstruction system provides a valuable tool for accurately capturing the shape and motion of these highly deformable robotic systems, which is critical for their development and real-world deployment, particularly in medical and other delicate applications.



This summary was produced with help from an AI and may contain inaccuracies - check out the links to read the original source documents!

Follow @aimodelsfyi on 𝕏 →

Related Papers

Three-dimensional Morphological Reconstruction of Millimeter-Scale Soft Continuum Robots based on Dual-Stereo-Vision
Total Score

0

Three-dimensional Morphological Reconstruction of Millimeter-Scale Soft Continuum Robots based on Dual-Stereo-Vision

Tian-Ao Ren, Wenyan Liu, Tao Zhang, Lei Zhao, Hongliang Ren, Jiewen Lai

Continuum robots can be miniaturized to just a few millimeters in diameter. Among these, notched tubular continuum robots (NTCR) show great potential in many delicate applications. Existing works in robotic modeling focus on kinematics and dynamics but still face challenges in reproducing the robot's morphology -- a significant factor that can expand the research landscape of continuum robots, especially for those with asymmetric continuum structures. This paper proposes a dual stereo vision-based method for the three-dimensional morphological reconstruction of millimeter-scale NTCRs. The method employs two oppositely located stationary binocular cameras to capture the point cloud of the NTCR, then utilizes predefined geometry as a reference for the KD tree method to relocate the capture point clouds, resulting in a morphologically correct NTCR despite the low-quality raw point cloud collection. The method has been proved feasible for an NTCR with a 3.5 mm diameter, capturing 14 out of 16 notch features, with the measurements generally centered around the standard of 1.5 mm, demonstrating the capability of revealing morphological details. Our proposed method paves the way for 3D morphological reconstruction of millimeter-scale soft robots for further self-modeling study.

Read more

8/19/2024

🔍

Total Score

0

An iterative closest point algorithm for marker-free 3D shape registration of continuum robots

Matthias K. Hoffmann, Julian Muhlenhoff, Zhaoheng Ding, Thomas Sattel, Kathrin Fla{ss}kamp

Continuum robots have emerged as a promising technology in the medical field due to their potential of accessing deep sited locations of the human body with low surgical trauma. When deriving physics-based models for these robots, evaluating the models poses a significant challenge due to the difficulty in accurately measuring their intricate shapes. In this work, we present an optimization based 3D shape registration algorithm for estimation of the backbone shape of slender continuum robots as part of a pho togrammetric measurement. Our approach to estimating the backbones optimally matches a parametric three-dimensional curve to images of the robot. Since we incorporate an iterative closest point algorithm into our method, we do not need prior knowledge of the robots position within the respective images. In our experiments with artificial and real images of a concentric tube continuum robot, we found an average maximum deviation of the reconstruction from simulation data of 0.665 mm and 0.939 mm from manual measurements. These results show that our algorithm is well capable of producing high accuracy positional data from images of continuum robots.

Read more

5/27/2024

📉

Total Score

0

A Low-Cost Teleoperable Surgical Robot with a Macro-Micro Structure and a Continuum Tip for Open-Source Research

Lachlan Scott, Tangyou Liu, Liao Wu

Surgical robotic systems equipped with microscale, high-dexterity manipulators have shown promising results in minimally invasive surgery (MIS). One barrier to the widespread adoption of such systems is the prohibitive cost of research and development efforts using current state-of-the-art equipment. To address this challenge, this paper proposes a low-cost and modifiable tendon-driven continuum manipulator for MIS applications. The device is capable of being teleoperated in conjunction with a macro-scale six-axis robotic arm using a haptic stylus. Its control software incorporates and extends freely available and open-source software packages. For verification, we perform teleoperation trials on the proposed continuum manipulator using an electromagnetic tracker. We then integrate the manipulator with a UR5e robotic arm. A series of simulated tumour biopsies were conducted using the integrated robotic system and an anatomical model (phantom), validating its potential efficacy in MIS applications. The complete source code, CAD files for all additively manufactured components, a parts list for the manipulator, and a demonstration video of the proposed system are made available in this work.

Read more

5/28/2024

Data-driven imaging geometric recovery of ultrahigh resolution robotic micro-CT for in-vivo and other applications
Total Score

0

Data-driven imaging geometric recovery of ultrahigh resolution robotic micro-CT for in-vivo and other applications

Mengzhou Li, Guibin Zan, Wenbin Yun, Josef Uher, John Wen, Ge Wang

We introduce an ultrahigh-resolution (50mu m) robotic micro-CT design for localized imaging of carotid plaques using robotic arms, cutting-edge detector, and machine learning technologies. To combat geometric error-induced artifacts in interior CT scans, we propose a data-driven geometry estimation method that maximizes the consistency between projection data and the reprojection counterparts of a reconstructed volume. Particularly, we use a normalized cross correlation metric to overcome the projection truncation effect. Our approach is validated on a robotic CT scan of a sacrificed mouse and a micro-CT phantom scan, both producing sharper images with finer details than that prior correction.

Read more

6/27/2024