Automatic Segmentation of the Kidneys and Cystic Renal Lesions on Non-Contrast CT Using a Convolutional Neural Network

Read original: arXiv:2405.08282 - Published 5/15/2024 by Lucas Aronson (Department of Radiology, University of Wisconsin School of Medicine & Public Health, Madison, WI, USA), Ruben Ngnitewe Massaa (Department of Radiology, University of Wisconsin School of Medicine & Public Health, Madison, WI, USA) and 20 others
Total Score

0

🧠

Sign in to get full access

or

If you already have an account, we'll log you in

Overview

  • This paper presents a deep learning model that can automatically segment kidneys and cystic renal lesions (CRLs) from non-contrast computed tomography (CT) scans.
  • Automated segmentation tools can quickly and accurately measure kidney volumes, and can also help facilitate large-scale medical imaging AI projects by generating labeled data.
  • Prior segmentation models have focused mainly on contrast-enhanced CT scans, but this work aims to develop a model for non-contrast CT scans, which are more commonly used in clinical practice.

Plain English Explanation

The researchers developed a deep learning algorithm that can automatically identify and outline the kidneys and kidney cysts (called cystic renal lesions or CRLs) in CT scans of the abdomen that do not use any contrast dye. Being able to automatically segment the kidneys and cysts is useful for quickly and precisely measuring the size of these structures, which is important for various medical applications.

Automated segmentation tools can also help advance medical imaging AI projects by providing accurately labeled training data, such as for image registration algorithms.

Previous studies have focused on developing segmentation models for contrast-enhanced CT scans, but non-contrast scans are more commonly used in clinical practice. So the researchers aimed to create a model that works well specifically on non-contrast CT images.

Technical Explanation

The researchers manually segmented the kidneys and CRLs in 150 non-contrast abdominal CT scans. They split the data into 80% for training and 20% for testing a deep learning model.

The model was trained to automatically segment the kidneys and CRLs from the non-contrast CT scans. The researchers evaluated the model's performance using various metrics, including the Dice Similarity Coefficient, Jaccard Index, and volume errors. They also compared the model's kidney volume measurements to the manual segmentations using Bland-Altman analysis.

Critical Analysis

The paper demonstrates that a deep learning model can achieve highly accurate segmentation of kidneys and CRLs on non-contrast CT scans, with a median Dice Similarity Coefficient of 0.934 for the kidneys. This is an impressive result, especially considering the model was trained on a relatively small dataset of 150 scans.

However, the model struggled more with segmenting the CRLs, with a median Dice score of 0.711. The researchers note that the variability and complexity of CRLs makes them more challenging to segment accurately. Further research may be needed to improve CRL segmentation and make the model more robust to a wider range of lesion types and sizes.

Additionally, the Bland-Altman analysis showed the model tended to overestimate kidney volumes compared to manual segmentation, with a mean bias of +3.0 ml. The wide limits of agreement (+/- 50.2 ml) also suggest there is room for improvement in the volume estimation accuracy.

Conclusion

This study demonstrates the potential for deep learning to enable rapid and accurate segmentation of kidneys and cystic renal lesions from routine non-contrast CT scans. Such automated tools could enhance kidney biopsy and lesion assessment workflows, as well as facilitate large-scale medical imaging AI research projects. Further refinements to improve CRL segmentation and volume measurement accuracy could make this approach even more clinically impactful.



This summary was produced with help from an AI and may contain inaccuracies - check out the links to read the original source documents!

Follow @aimodelsfyi on 𝕏 →

Related Papers

🧠

Total Score

0

Automatic Segmentation of the Kidneys and Cystic Renal Lesions on Non-Contrast CT Using a Convolutional Neural Network

Lucas Aronson (Department of Radiology, University of Wisconsin School of Medicine & Public Health, Madison, WI, USA), Ruben Ngnitewe Massaa (Department of Radiology, University of Wisconsin School of Medicine & Public Health, Madison, WI, USA), Syed Jamal Safdar Gardezi (Department of Radiology, University of Wisconsin School of Medicine & Public Health, Madison, WI, USA), Andrew L. Wentland (Department of Radiology, University of Wisconsin School of Medicine & Public Health, Madison, WI, USA, Department of Medical Physics, University of Wisconsin School of Medicine & Public Health, Madison, WI, USA, Department of Biomedical Engineering, University of Wisconsin School of Medicine & Public Health, Madison, WI, USA)

Objective: Automated segmentation tools are useful for calculating kidney volumes rapidly and accurately. Furthermore, these tools have the power to facilitate large-scale image-based artificial intelligence projects by generating input labels, such as for image registration algorithms. Prior automated segmentation models have largely ignored non-contrast computed tomography (CT) imaging. This work aims to implement and train a deep learning (DL) model to segment the kidneys and cystic renal lesions (CRLs) from non-contrast CT scans. Methods: Manual segmentation of the kidneys and CRLs was performed on 150 non-contrast abdominal CT scans. The data were divided into an 80/20 train/test split and a deep learning (DL) model was trained to segment the kidneys and CRLs. Various scoring metrics were used to assess model performance, including the Dice Similarity Coefficient (DSC), Jaccard Index (JI), and absolute and percent error kidney volume and lesion volume. Bland-Altman (B-A) analysis was performed to compare manual versus DL-based kidney volumes. Results: The DL model achieved a median kidney DSC of 0.934, median CRL DSC of 0.711, and total median study DSC of 0.823. Average volume errors were 0.9% for renal parenchyma, 37.0% for CRLs, and 2.2% overall. B-A analysis demonstrated that DL-based volumes tended to be greater than manual volumes, with a mean bias of +3.0 ml (+/- 2 SD of +/- 50.2 ml). Conclusion: A deep learning model trained to segment kidneys and cystic renal lesions on non-contrast CT examinations was able to provide highly accurate segmentations, with a median kidney Dice Similarity Coefficient of 0.934. Keywords: deep learning; kidney segmentation; artificial intelligence; convolutional neural networks.

Read more

5/15/2024

🔎

Total Score

0

Counterfactuals and Uncertainty-Based Explainable Paradigm for the Automated Detection and Segmentation of Renal Cysts in Computed Tomography Images: A Multi-Center Study

Zohaib Salahuddin, Abdalla Ibrahim, Sheng Kuang, Yousif Widaatalla, Razvan L. Miclea, Oliver Morin, Spencer Behr, Marnix P. M. Kop, Tom Marcelissen, Patricia Zondervan, Auke Jager, Philippe Lambin, Henry C Woodruff

Routine computed tomography (CT) scans often detect a wide range of renal cysts, some of which may be malignant. Early and precise localization of these cysts can significantly aid quantitative image analysis. Current segmentation methods, however, do not offer sufficient interpretability at the feature and pixel levels, emphasizing the necessity for an explainable framework that can detect and rectify model inaccuracies. We developed an interpretable segmentation framework and validated it on a multi-centric dataset. A Variational Autoencoder Generative Adversarial Network (VAE-GAN) was employed to learn the latent representation of 3D input patches and reconstruct input images. Modifications in the latent representation using the gradient of the segmentation model generated counterfactual explanations for varying dice similarity coefficients (DSC). Radiomics features extracted from these counterfactual images, using a ground truth cyst mask, were analyzed to determine their correlation with segmentation performance. The DSCs for the original and VAE-GAN reconstructed images for counterfactual image generation showed no significant differences. Counterfactual explanations highlighted how variations in cyst image features influence segmentation outcomes and showed model discrepancies. Radiomics features correlating positively and negatively with dice scores were identified. The uncertainty of the predicted segmentation masks was estimated using posterior sampling of the weight space. The combination of counterfactual explanations and uncertainty maps provided a deeper understanding of the image features within the segmented renal cysts that lead to high uncertainty. The proposed segmentation framework not only achieved high segmentation accuracy but also increased interpretability regarding how image features impact segmentation performance.

Read more

8/9/2024

🤿

Total Score

0

Deep Learning Segmentation of Ascites on Abdominal CT Scans for Automatic Volume Quantification

Benjamin Hou, Sung-Won Lee, Jung-Min Lee, Christopher Koh, Jing Xiao, Perry J. Pickhardt, Ronald M. Summers

Purpose: To evaluate the performance of an automated deep learning method in detecting ascites and subsequently quantifying its volume in patients with liver cirrhosis and ovarian cancer. Materials and Methods: This retrospective study included contrast-enhanced and non-contrast abdominal-pelvic CT scans of patients with cirrhotic ascites and patients with ovarian cancer from two institutions, National Institutes of Health (NIH) and University of Wisconsin (UofW). The model, trained on The Cancer Genome Atlas Ovarian Cancer dataset (mean age, 60 years +/- 11 [s.d.]; 143 female), was tested on two internal (NIH-LC and NIH-OV) and one external dataset (UofW-LC). Its performance was measured by the Dice coefficient, standard deviations, and 95% confidence intervals, focusing on ascites volume in the peritoneal cavity. Results: On NIH-LC (25 patients; mean age, 59 years +/- 14 [s.d.]; 14 male) and NIH-OV (166 patients; mean age, 65 years +/- 9 [s.d.]; all female), the model achieved Dice scores of 0.855 +/- 0.061 (CI: 0.831-0.878) and 0.826 +/- 0.153 (CI: 0.764-0.887), with median volume estimation errors of 19.6% (IQR: 13.2-29.0) and 5.3% (IQR: 2.4-9.7) respectively. On UofW-LC (124 patients; mean age, 46 years +/- 12 [s.d.]; 73 female), the model had a Dice score of 0.830 +/- 0.107 (CI: 0.798-0.863) and median volume estimation error of 9.7% (IQR: 4.5-15.1). The model showed strong agreement with expert assessments, with r^2 values of 0.79, 0.98, and 0.97 across the test sets. Conclusion: The proposed deep learning method performed well in segmenting and quantifying the volume of ascites in concordance with expert radiologist assessments.

Read more

6/26/2024

Deep learning-based brain segmentation model performance validation with clinical radiotherapy CT
Total Score

0

Deep learning-based brain segmentation model performance validation with clinical radiotherapy CT

Selena Huisman, Matteo Maspero, Marielle Philippens, Joost Verhoeff, Szabolcs David

Manual segmentation of medical images is labor intensive and especially challenging for images with poor contrast or resolution. The presence of disease exacerbates this further, increasing the need for an automated solution. To this extent, SynthSeg is a robust deep learning model designed for automatic brain segmentation across various contrasts and resolutions. This study validates the SynthSeg robust brain segmentation model on computed tomography (CT), using a multi-center dataset. An open access dataset of 260 paired CT and magnetic resonance imaging (MRI) from radiotherapy patients treated in 5 centers was collected. Brain segmentations from CT and MRI were obtained with SynthSeg model, a component of the Freesurfer imaging suite. These segmentations were compared and evaluated using Dice scores and Hausdorff 95 distance (HD95), treating MRI-based segmentations as the ground truth. Brain regions that failed to meet performance criteria were excluded based on automated quality control (QC) scores. Dice scores indicate a median overlap of 0.76 (IQR: 0.65-0.83). The median HD95 is 2.95 mm (IQR: 1.73-5.39). QC score based thresholding improves median dice by 0.1 and median HD95 by 0.05mm. Morphological differences related to sex and age, as detected by MRI, were also replicated with CT, with an approximate 17% difference between the CT and MRI results for sex and 10% difference between the results for age. SynthSeg can be utilized for CT-based automatic brain segmentation, but only in applications where precision is not essential. CT performance is lower than MRI based on the integrated QC scores, but low-quality segmentations can be excluded with QC-based thresholding. Additionally, performing CT-based neuroanatomical studies is encouraged, as the results show correlations in sex- and age-based analyses similar to those found with MRI.

Read more

6/26/2024