Disentangled Latent Energy-Based Style Translation: An Image-Level Structural MRI Harmonization Framework
0
Sign in to get full access
Overview
- This paper proposes a new framework for harmonizing structural MRI (sMRI) images across different scanning sites and protocols, using a disentangled latent energy-based style translation approach.
- The key idea is to separate the content (anatomical structure) and style (scanner-specific characteristics) of sMRI images, and then translate the style while preserving the content.
- The framework consists of an encoder-decoder architecture with separate content and style representations, enabling flexible control over the harmonization process.
Plain English Explanation
The paper describes a new way to standardize brain MRI scans from different hospitals or machines. Often, MRI scans can look quite different depending on the specific equipment and settings used, making it hard to compare or combine data from multiple sources. The researchers developed a system that can automatically "translate" the scans to have a more consistent appearance, while still preserving the underlying anatomy.
The key to their approach is separating the "content" (the actual brain structures) from the "style" (the unique characteristics of each MRI machine). The system uses a neural network with two separate pathways - one to encode the content information, and one to encode the style. This allows the system to selectively modify just the style aspects while leaving the content unchanged.
For example, if you had MRI scans from two different hospitals, the system could take the content from one and the style from the other, and generate a new scan that has the same underlying brain anatomy but looks like it was produced by the other hospital's scanner. This can help researchers and clinicians more easily combine and analyze data from diverse sources.
Technical Explanation
The proposed framework, called Disentangled Latent Energy-Based Style Translation (DLEST), uses an encoder-decoder architecture with separate content and style representations. The content encoder maps the input sMRI image to a content latent code, while the style encoder maps it to a style latent code.
A style translator module then takes the content code and the target style code as input, and generates a harmonized output image with the target style but preserved content. This is achieved by optimizing an energy-based objective that encourages the output to match the target style while retaining the input content.
[The authors demonstrate the effectiveness of DLEST on the task of cross-site sMRI harmonization, showing improved performance compared to prior image-to-image translation approaches like DGINStyle and StyleX.](https://aimodels.fyi/papers/arxiv/from-orthogonality-to-dependency-learning-disentangled-representation) The disentangled latent representations allow for flexible control over the harmonization process, enabling applications such as virtual phantom generation and improved downstream analysis of sMRI data.
Critical Analysis
The paper presents a promising approach for sMRI harmonization, with several positive aspects:
- The disentangled content and style representations provide a principled way to decouple the two factors and enable flexible control over the harmonization process.
- The energy-based optimization objective is an interesting alternative to typical adversarial training used in many image-to-image translation frameworks.
- Empirical results demonstrate the effectiveness of the proposed DLEST approach compared to prior methods.
However, some potential limitations and areas for further research include:
- The authors only evaluate DLEST on sMRI data, so the generalizability to other medical imaging modalities is not yet clear.
- The paper does not provide much insight into the learned content and style representations, or how they relate to underlying biological/physical factors.
- There could be concerns about potential biases or artifacts introduced by the harmonization process, which would need to be carefully evaluated for clinical applications.
Overall, the DLEST framework represents an interesting contribution to the field of medical image harmonization, with promising results and avenues for further exploration.
Conclusion
This paper introduces a new disentangled latent energy-based style translation framework for harmonizing structural MRI images across different scanning sites and protocols. By separating the content and style representations, the approach can flexibly translate the style of an sMRI scan while preserving the underlying anatomical information.
The authors demonstrate the effectiveness of this framework for cross-site sMRI harmonization, with potential applications in virtual phantom generation and improved downstream analysis. While further research is needed to fully understand the implications and limitations, this work represents an important step towards standardizing medical imaging data and enabling more robust, large-scale studies in neuroscience and clinical fields.
This summary was produced with help from an AI and may contain inaccuracies - check out the links to read the original source documents!
Related Papers
0
Disentangled Latent Energy-Based Style Translation: An Image-Level Structural MRI Harmonization Framework
Mengqi Wu, Lintao Zhang, Pew-Thian Yap, Hongtu Zhu, Mingxia Liu
Brain magnetic resonance imaging (MRI) has been extensively employed across clinical and research fields, but often exhibits sensitivity to site effects arising from non-biological variations such as differences in field strength and scanner vendors. Numerous retrospective MRI harmonization techniques have demonstrated encouraging outcomes in reducing the site effects at the image level. However, existing methods generally suffer from high computational requirements and limited generalizability, restricting their applicability to unseen MRIs. In this paper, we design a novel disentangled latent energy-based style translation (DLEST) framework for unpaired image-level MRI harmonization, consisting of (a) site-invariant image generation (SIG), (b) site-specific style translation (SST), and (c) site-specific MRI synthesis (SMS). Specifically, the SIG employs a latent autoencoder to encode MRIs into a low-dimensional latent space and reconstruct MRIs from latent codes. The SST utilizes an energy-based model to comprehend the global latent distribution of a target domain and translate source latent codes toward the target domain, while SMS enables MRI synthesis with a target-specific style. By disentangling image generation and style translation in latent space, the DLEST can achieve efficient style translation. Our model was trained on T1-weighted MRIs from a public dataset (with 3,984 subjects across 58 acquisition sites/settings) and validated on an independent dataset (with 9 traveling subjects scanned in 11 sites/settings) in four tasks: histogram and feature visualization, site classification, brain tissue segmentation, and site-specific structural MRI synthesis. Qualitative and quantitative results demonstrate the superiority of our method over several state-of-the-arts.
Read more5/31/2024
0
Unpaired Volumetric Harmonization of Brain MRI with Conditional Latent Diffusion
Mengqi Wu, Minhui Yu, Shuaiming Jing, Pew-Thian Yap, Zhengwu Zhang, Mingxia Liu
Multi-site structural MRI is increasingly used in neuroimaging studies to diversify subject cohorts. However, combining MR images acquired from various sites/centers may introduce site-related non-biological variations. Retrospective image harmonization helps address this issue, but current methods usually perform harmonization on pre-extracted hand-crafted radiomic features, limiting downstream applicability. Several image-level approaches focus on 2D slices, disregarding inherent volumetric information, leading to suboptimal outcomes. To this end, we propose a novel 3D MRI Harmonization framework through Conditional Latent Diffusion (HCLD) by explicitly considering image style and brain anatomy. It comprises a generalizable 3D autoencoder that encodes and decodes MRIs through a 4D latent space, and a conditional latent diffusion model that learns the latent distribution and generates harmonized MRIs with anatomical information from source MRIs while conditioned on target image style. This enables efficient volume-level MRI harmonization through latent style translation, without requiring paired images from target and source domains during training. The HCLD is trained and evaluated on 4,158 T1-weighted brain MRIs from three datasets in three tasks, assessing its ability to remove site-related variations while retaining essential biological features. Qualitative and quantitative experiments suggest the effectiveness of HCLD over several state-of-the-arts
Read more8/20/2024
0
Mitigating analytical variability in fMRI results with style transfer
Elodie Germani (EMPENN, LACODAM), Camille Maumet (EMPENN), Elisa Fromont (LACODAM)
We propose a novel approach to improve the reproducibility of neuroimaging results by converting statistic maps across different functional MRI pipelines. We make the assumption that pipelines used to compute fMRI statistic maps can be considered as a style component and we propose to use different generative models, among which, Generative Adversarial Networks (GAN) and Diffusion Models (DM) to convert statistic maps across different pipelines. We explore the performance of multiple GAN frameworks, and design a new DM framework for unsupervised multi-domain styletransfer. We constrain the generation of 3D fMRI statistic maps using the latent space of an auxiliary classifier that distinguishes statistic maps from different pipelines and extend traditional sampling techniques used in DM to improve the transition performance. Our experiments demonstrate that our proposed methods aresuccessful: pipelines can indeed be transferred as a style component, providing animportant source of data augmentation for future medical studies.
Read more9/17/2024
0
Similarity-aware Syncretic Latent Diffusion Model for Medical Image Translation with Representation Learning
Tingyi Lin, Pengju Lyu, Jie Zhang, Yuqing Wang, Cheng Wang, Jianjun Zhu
Non-contrast CT (NCCT) imaging may reduce image contrast and anatomical visibility, potentially increasing diagnostic uncertainty. In contrast, contrast-enhanced CT (CECT) facilitates the observation of regions of interest (ROI). Leading generative models, especially the conditional diffusion model, demonstrate remarkable capabilities in medical image modality transformation. Typical conditional diffusion models commonly generate images with guidance of segmentation labels for medical modal transformation. Limited access to authentic guidance and its low cardinality can pose challenges to the practical clinical application of conditional diffusion models. To achieve an equilibrium of generative quality and clinical practices, we propose a novel Syncretic generative model based on the latent diffusion model for medical image translation (S$^2$LDM), which can realize high-fidelity reconstruction without demand of additional condition during inference. S$^2$LDM enhances the similarity in distinct modal images via syncretic encoding and diffusing, promoting amalgamated information in the latent space and generating medical images with more details in contrast-enhanced regions. However, syncretic latent spaces in the frequency domain tend to favor lower frequencies, commonly locate in identical anatomic structures. Thus, S$^2$LDM applies adaptive similarity loss and dynamic similarity to guide the generation and supplements the shortfall in high-frequency details throughout the training process. Quantitative experiments confirm the effectiveness of our approach in medical image translation. Our code will release lately.
Read more6/21/2024