Unpaired Volumetric Harmonization of Brain MRI with Conditional Latent Diffusion

Read original: arXiv:2408.09315 - Published 8/20/2024 by Mengqi Wu, Minhui Yu, Shuaiming Jing, Pew-Thian Yap, Zhengwu Zhang, Mingxia Liu
Total Score

0

Unpaired Volumetric Harmonization of Brain MRI with Conditional Latent Diffusion

Sign in to get full access

or

If you already have an account, we'll log you in

Overview

  • This paper proposes an unpaired volumetric harmonization method for brain MRI using a conditional latent diffusion model.
  • The method aims to harmonize brain MRI scans from different scanners or protocols without requiring paired training data.
  • It leverages a conditional latent diffusion model to learn a harmonization mapping in the latent space, allowing for efficient and high-quality harmonization.

Plain English Explanation

Brain MRI (Magnetic Resonance Imaging) scans are important for medical diagnosis and research, but they can vary in quality and appearance depending on the scanner used and the imaging protocol. This paper introduces a new method to "harmonize" these brain MRI scans, making them more consistent and easier to compare across different settings.

The key innovation is the use of a conditional latent diffusion model, which learns to transform the scans in a hidden "latent" space rather than directly on the image pixels. This allows the method to work even when the researchers don't have perfectly matched pairs of scans from different scanners - a common challenge in medical imaging research.

By harmonizing the brain MRI scans, this approach can help doctors and researchers get more accurate and reliable insights from the data, which is important for tasks like diagnosing diseases or understanding brain structure and function. The authors demonstrate that their method can produce high-quality harmonized scans without needing the paired training data that many previous techniques required.

Technical Explanation

The paper presents an unpaired volumetric harmonization method for brain MRI that leverages a conditional latent diffusion model. This allows the model to learn a harmonization mapping in the latent space without requiring paired training data from different scanners or protocols.

The key components of the approach are:

  1. An encoder-decoder autoencoder architecture that learns a latent representation of the input brain MRI scans.
  2. A conditional latent diffusion model that is trained to transform the latent representations to harmonize the scans.
  3. A discriminator network that helps the diffusion model learn an effective harmonization mapping.

The authors evaluate their method on a dataset of brain MRI scans from multiple scanners and show that it can produce high-quality harmonized outputs without requiring paired training data. This is a significant advantage over previous harmonization techniques that relied on having perfectly matched scan pairs.

Critical Analysis

The paper makes a compelling case for the value of the proposed unpaired volumetric harmonization approach for brain MRI. The use of a conditional latent diffusion model is a clever way to address the challenge of needing paired training data, which is often difficult to obtain in medical imaging.

However, the paper does not deeply explore some potential limitations or areas for further research. For example, it would be interesting to understand how the method performs on scans with more extreme differences in quality or acquisition parameters, or how it compares to other recent developments in latent diffusion models for medical imaging applications.

Additionally, while the authors demonstrate good qualitative and quantitative results, further validation on larger and more diverse datasets would help strengthen the claims about the method's broader applicability and robustness.

Conclusion

This paper presents a novel unpaired volumetric harmonization approach for brain MRI that leverages a conditional latent diffusion model. By learning a harmonization mapping in the latent space, the method can effectively transform brain MRI scans from different scanners or protocols without requiring paired training data - a common challenge in medical imaging research.

The proposed technique has the potential to significantly improve the consistency and reliability of brain MRI analysis, which is crucial for diagnostic, research, and clinical applications. While the paper could delve deeper into certain limitations and areas for future work, it represents an important step forward in the field of medical image harmonization.



This summary was produced with help from an AI and may contain inaccuracies - check out the links to read the original source documents!

Follow @aimodelsfyi on 𝕏 →

Related Papers

Unpaired Volumetric Harmonization of Brain MRI with Conditional Latent Diffusion
Total Score

0

Unpaired Volumetric Harmonization of Brain MRI with Conditional Latent Diffusion

Mengqi Wu, Minhui Yu, Shuaiming Jing, Pew-Thian Yap, Zhengwu Zhang, Mingxia Liu

Multi-site structural MRI is increasingly used in neuroimaging studies to diversify subject cohorts. However, combining MR images acquired from various sites/centers may introduce site-related non-biological variations. Retrospective image harmonization helps address this issue, but current methods usually perform harmonization on pre-extracted hand-crafted radiomic features, limiting downstream applicability. Several image-level approaches focus on 2D slices, disregarding inherent volumetric information, leading to suboptimal outcomes. To this end, we propose a novel 3D MRI Harmonization framework through Conditional Latent Diffusion (HCLD) by explicitly considering image style and brain anatomy. It comprises a generalizable 3D autoencoder that encodes and decodes MRIs through a 4D latent space, and a conditional latent diffusion model that learns the latent distribution and generates harmonized MRIs with anatomical information from source MRIs while conditioned on target image style. This enables efficient volume-level MRI harmonization through latent style translation, without requiring paired images from target and source domains during training. The HCLD is trained and evaluated on 4,158 T1-weighted brain MRIs from three datasets in three tasks, assessing its ability to remove site-related variations while retaining essential biological features. Qualitative and quantitative experiments suggest the effectiveness of HCLD over several state-of-the-arts

Read more

8/20/2024

Disentangled Latent Energy-Based Style Translation: An Image-Level Structural MRI Harmonization Framework
Total Score

0

Disentangled Latent Energy-Based Style Translation: An Image-Level Structural MRI Harmonization Framework

Mengqi Wu, Lintao Zhang, Pew-Thian Yap, Hongtu Zhu, Mingxia Liu

Brain magnetic resonance imaging (MRI) has been extensively employed across clinical and research fields, but often exhibits sensitivity to site effects arising from non-biological variations such as differences in field strength and scanner vendors. Numerous retrospective MRI harmonization techniques have demonstrated encouraging outcomes in reducing the site effects at the image level. However, existing methods generally suffer from high computational requirements and limited generalizability, restricting their applicability to unseen MRIs. In this paper, we design a novel disentangled latent energy-based style translation (DLEST) framework for unpaired image-level MRI harmonization, consisting of (a) site-invariant image generation (SIG), (b) site-specific style translation (SST), and (c) site-specific MRI synthesis (SMS). Specifically, the SIG employs a latent autoencoder to encode MRIs into a low-dimensional latent space and reconstruct MRIs from latent codes. The SST utilizes an energy-based model to comprehend the global latent distribution of a target domain and translate source latent codes toward the target domain, while SMS enables MRI synthesis with a target-specific style. By disentangling image generation and style translation in latent space, the DLEST can achieve efficient style translation. Our model was trained on T1-weighted MRIs from a public dataset (with 3,984 subjects across 58 acquisition sites/settings) and validated on an independent dataset (with 9 traveling subjects scanned in 11 sites/settings) in four tasks: histogram and feature visualization, site classification, brain tissue segmentation, and site-specific structural MRI synthesis. Qualitative and quantitative results demonstrate the superiority of our method over several state-of-the-arts.

Read more

5/31/2024

Diffusion based multi-domain neuroimaging harmonization method with preservation of anatomical details
Total Score

0

Diffusion based multi-domain neuroimaging harmonization method with preservation of anatomical details

Haoyu Lan, Bino A. Varghese, Nasim Sheikh-Bahaei, Farshid Sepehrband, Arthur W Toga, Jeiran Choupan

Multi-center neuroimaging studies face technical variability due to batch differences across sites, which potentially hinders data aggregation and impacts study reliability.Recent efforts in neuroimaging harmonization have aimed to minimize these technical gaps and reduce technical variability across batches. While Generative Adversarial Networks (GAN) has been a prominent method for addressing image harmonization tasks, GAN-harmonized images suffer from artifacts or anatomical distortions. Given the advancements of denoising diffusion probabilistic model which produces high-fidelity images, we have assessed the efficacy of the diffusion model for neuroimaging harmonization. we have demonstrated the diffusion model's superior capability in harmonizing images from multiple domains, while GAN-based methods are limited to harmonizing images between two domains per model. Our experiments highlight that the learned domain invariant anatomical condition reinforces the model to accurately preserve the anatomical details while differentiating batch differences at each diffusion step. Our proposed method has been tested on two public neuroimaging dataset ADNI1 and ABIDE II, yielding harmonization results with consistent anatomy preservation and superior FID score compared to the GAN-based methods. We have conducted multiple analysis including extensive quantitative and qualitative evaluations against the baseline models, ablation study showcasing the benefits of the learned conditions, and improvements in the consistency of perivascular spaces (PVS) segmentation through harmonization.

Read more

9/4/2024

DiffHarmony: Latent Diffusion Model Meets Image Harmonization
Total Score

0

DiffHarmony: Latent Diffusion Model Meets Image Harmonization

Pengfei Zhou, Fangxiang Feng, Xiaojie Wang

Image harmonization, which involves adjusting the foreground of a composite image to attain a unified visual consistency with the background, can be conceptualized as an image-to-image translation task. Diffusion models have recently promoted the rapid development of image-to-image translation tasks . However, training diffusion models from scratch is computationally intensive. Fine-tuning pre-trained latent diffusion models entails dealing with the reconstruction error induced by the image compression autoencoder, making it unsuitable for image generation tasks that involve pixel-level evaluation metrics. To deal with these issues, in this paper, we first adapt a pre-trained latent diffusion model to the image harmonization task to generate the harmonious but potentially blurry initial images. Then we implement two strategies: utilizing higher-resolution images during inference and incorporating an additional refinement stage, to further enhance the clarity of the initially harmonized images. Extensive experiments on iHarmony4 datasets demonstrate the superiority of our proposed method. The code and model will be made publicly available at https://github.com/nicecv/DiffHarmony .

Read more

4/10/2024